Characterizations of Membrane for Water Treatment: Surface Charge Analysis by Electrophoresis and Acidity Measurements

  • Yongki Shim;Lee, Sangyoup;Moon, Seung-Hyeon;Jaeweon Cho
    • Korean Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.56-59
    • /
    • 2000
  • The surface charge properties of a polymeric NF and a ceramic UF membranes were characterized in terms of zeta potential and acidity. Both the negative zeta potential and acidity values increased as pH increases due to ionizable acidic functional groups. Increased ionic strength reduced the acidity of the negatively-charged membrane surface as anticipated. Through these results, it can be envisioned are used to reject solutes with ionizable functional groups. Fouling of the negatively-charged membrane with natural organic matter (NOM) having a negative charge density was also investigated with respect to the surface charge. The surface charge of the NF membrane increased negatively when greater NOM adsorption onto the membrane surface occured.

  • PDF

Study on the Interaction of U(VI) Species With Natural Organic Matters in KURT Groundwater (KURT 지하수의 천연 유기물질과 6가 우라늄 화학종의 상호작용에 관한 연구)

  • Jung, Euo Chang;Baik, Min Hoon;Cho, Hye-Ryun;Kim, Hee-Kyung;Cha, Wansik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.101-116
    • /
    • 2017
  • The interaction of U(VI) (hexavalent uranium) species with natural organic matter (NOM) in KURT (KAERI Underground Research Tunnel) groundwater is investigated using a laser spectroscopic technique. The luminescence spectra of the NOM are observed in the ultraviolet and blue wavelength regions by irradiating a laser beam at 266 nm in groundwater. The luminescence spectra of U(VI) species in groundwater containing uranium concentrations of $0.034-0.788mg{\cdot}L^{-1}$ are measured in the green-colored wavelength region. The luminescence characteristics (peak wavelengths and lifetime) of U(VI) in the groundwater agree well with those of $Ca_2UO_2(CO_3)_3(aq)$ in a standard solution prepared in a laboratory. The luminescence intensities of U(VI) in the groundwater are weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. The luminescence intensities of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution mixed with the groundwater are also weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. These results can be ascribed to calcium-U(VI)-carbonate species interacting with NOM and forming non-radiative U(VI) complexes in groundwater.

Removal of Perchlorate Using Reverse Osmosis and Nanofiltration Membranes

  • Han, Jonghun;Kong, Choongsik;Heo, Jiyong;Yoon, Yeomin;Lee, Heebum;Her, Namguk
    • Environmental Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.185-190
    • /
    • 2012
  • Rejection characteristics of perchlorate ($ClO_4^-$) were examined for commercially available reverse osmosis (RO) and nanofiltration (NF) membranes. A bench-scale dead-end stirred-cell filtration system was employed to determine the toxic ion rejection and the membrane flux. Model water solutions were used to prepare $ClO_4^-$ solutions (approximately, $1,000{\mu}g/L$) in the presence of background salts (NaCl, $Na_2SO_4$, and $CaCl_2$) at various pH values (3.5, 7, and 9.5) and solution ionic strengths (0.001, 0.01, and 0.01 M NaCl) in the presence of natural organic matter (NOM). Rejection by the membranes increased with increasing solution pH owing to increasingly negative membrane charge. In addition, the rejection of the target ion by the membranes increased with increasing solution ionic strength. The rejection of $ClO_4^-$ was consistently higher for the RO membrane than for the NF membrane and $ClO_4^-$ rejection followed the order $CaCl_2$ < NaCl < $Na_2SO_4$ at conditions of constant pH and ionic strength for both the RO and NF membranes. The possible influence of NOM on $ClO_4^-$ rejection by the membranes was also explored.

Evaluation of Haloacetic Acid Formation Potential in Drinking Water Treatment Process by Fraction Technique (정수처리 공정에서 용존 유기물질 분류에 의한 haloacetic acid 생성능 평가)

  • Son, Hee-Jong;Hwang, Young-Do;Ryu, Dong-Choon;Jung, Chul-Woo;Lee, Gun;Son, Hyeng-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1655-1662
    • /
    • 2014
  • A comprehensive fractionation technique was applied to a set of water samples obtained along drinking water treatment process with ozonation and biological activated carbon (BAC) process to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that coagulation-sedimentation-sand filtration treatment showed limited ability to remove hydrophilic fraction (28%), while removal of hydrophobic and transphilic fraction were 57% and 40%, respectively. And ozonation and BAC treatment showed limited ability to remove hydrophobic fractions (6%), while removal of hydrophilic and transphilic fractions were 25% and 18%. The haloacetic acid formation potential (HAAFP)/dissolved organic carbon (DOC) of hydrophilic fraction was the highest along the treatment train and HAAFP/DOC of hydrophilic fraction was higher than hydrophobic and transphilic fraction as 23%~30%, because of better removal for hydrophobic fraction both in concentration and reactivity.

The Removal and Adsorption Characteristics of 2-MIB & Geosmin using PAC (PAC를 이용한 2-MIB와 Geosmin의 흡착특성과 제거에 관한 연구)

  • Jun, Dae-Young;Lee, Hyeon-Ju;Hong, Seongho;Yoon, Jeyong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2097-2104
    • /
    • 2000
  • Naturally occurring taste and odor problems include those produced by microorganism. notably algae and bacteria. The major compounds causing taste and odor are MIB and Geosmin which can cause earthy-musty at very low concentration 9ng/L and 4ng/L, respectively. Especially, the problem is very serious from summer to fall in source and finished water. It is well known that using PAC is one of the best technology to control these compounds in drinking water treatment. In this study, optimum dosage and dosing time of PAC were observed with the adsorption isotherm experiments in single and binary compounds. Also, the effect of natural organic matter(NOM) was investigated by using a natural water with JSW. The adsorption capacity of Geosmin was higher than MIB in both with NOM and without NOM. The adsorption capacity of Geosmin and MIB was 4 times lower with NOM than that of without NOM. which was caused by competition adsorption. When the initial concentration of Geosmin and MIB were 100ng/L in JSW, at least 4 hours of reaction time was needed to achieve 99% removal with 20mg/L of the PAC.

  • PDF

Physicochemical and Toxicological Properties of Effluent Organic Matters from Sewage and Industrial Treatment Plants (하폐수처리장 유래 방류수유기물질의 물리화학적 및 독성학적 특성)

  • Yoo, Jisu;Lee, Bomi;Hur, Jin;Jung, Jinho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.80-86
    • /
    • 2014
  • Unlike to natural organic matters (NOMs), effluent organic matters (EfOMs) are not well understood due to their complexity and heterogeneity. In this study, EfOMs from sewage and industrial wastewater treatment effluents and Suwannee River NOM (SRNOM) were isolated into hydrophobic (HPO), transphilic (TPI) and hydrophilic (HPI) fractions. Specific ultraviolet absorbance (SUVA) and fluorescence excitation emission matrix (FEEM) analyses were used to characterize physicochemical properties. In addition, acute toxicity and oxidative stress to Daphnia magna were evaluated to characterize toxicological properties. EfOMs showed similar properties to microbially derived organic matters having low hydrophobicity, which are totally different from SRNOM having high hydrophobicity. Moreover, acute toxicity and antioxidant enzyme activity in D. magna was largely dependent on fraction types of EfOMs. These findings suggest that EfOMs have different physicochemical and toxicological properties compared with those of NOMs, which needs to be further identified with various sources of EfOMs.

Evaluation of Granular Activated Carbon Process Focusing on Molar mass and size distribution of DOM (DOM의 분자량과 크기분포에 따른 입상활성탄 공정의 평가)

  • Chae, Seon H.;Lee, Kyung H .
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • The primary objective of this study was to evaluate the variation of the molecular size distribution by granular activated carbon (GAC) adsorption. GAC adsorption was assessed by using the rapid small-scale column test (RSSCT) and high-performance size-exclusion chromatography (HPSEC) was used to analyze the molecular size distribution (MSD) in the effluent of GAC column. RSSCT study suggested that GAC adsorption exhibited excellent interrelationship between dissolved organic carbon (DOC) breakthrough and MSD as function of bed volumes passed. After GAC treatment, the nonadsorbable fraction which was about 25percents of influent DOC corresponded to the hydrophilic (HPI) natural organic carbon (NOM) of NOM fractions and was composed entirely of <300 molecular weight (MW) in the HPSEC at the initial stage of the RSSCT operation. The dominant MW fraction in the source water was 1,000~5,000daltons. At the bed volumes 2,500, MW <500 of GAC treated water was risen rather than it of source water. After the bed volumes 7,300 of operation, the MW 1,000~3,000 fraction was closed to about 80percents of DOC found in the GAC influent. The Number-average molecular weight (Mn) value determined using HPSEC for the effluent of GAC column was gently increased as DOC breakthrough progress. The quotient p(Mw/Mn) can be used to estimate the degree of polydispersity was shown greatest value for the GAC effluent at the initial stage of the RSSCT operation.

Changes in Dissolved Organic Matter Composition in the Namhan River during a Heavy Rain Event (집중 강우시 남한강 내 용존 유기물의 성상 변화)

  • Oh, Seijin;Woo, Sungho;Hur, Jin;Jung, Myung-Sook;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.697-703
    • /
    • 2009
  • In this study, changes in the composition of dissolved organic carbon (DOC) were investigated using water samples collected at a downstream site of the Namhan River near the Lake Paldang ($N37^{\circ}24^{\prime}05.33^{{\prime}{\prime}}E127^{\circ}32^{\prime}25.01^{{\prime}{\prime}}$) during a heavy rain event from July 23 to July 28, 2008. The DOC concentrations varied from 1.68 to 3.18 mg/L with the maxium value at a peak of the river water level. Each DOC sample was fractionated into three compositions including hydrophilic (Hi), hydrophobic acid (HoA) and hydrophobic neutral (HoN) fractions. The results showed that HoA was most abundant fractions, constituting 47.2~56.5% of DOC. Refractory dissolved organic carbon (R-DOC) contents were also determined by measuring the DOC concentration after 28-day dark incubation of the samples. R-DOC content was in the range from 83 to 99% of DOC and it was significantly correlated with HoA contents (r = 0.91, p<0.005), while it did not exhibit such a good correlation with the fractions of Hi and HoN (p>0.02). Our results suggest that the HoA, which is associated with humic substances, may be a major composition of refractory organic matters in rivers during storm events.

Trihalomethane formation potential of drinking water sources in a rural location

  • Rajamohan, R.;Ebenezer, Vinitha;Rajesh, Puspalata;Venugopalan, V.P.;Natesan, Usha;Murugesan, V.;Narasimhan, S.V.
    • Advances in environmental research
    • /
    • v.1 no.3
    • /
    • pp.181-189
    • /
    • 2012
  • Trihalomethanes, produced as a result of chlorination of drinking water, are considered a potential health hazard. The trihalomethane formation potential (THMFP) of a raw water source may indicate the maximum trihalomethanes (THMs) that are likely to be produced when chlorine reacts with natural organic matter (NOM) present in the water. A study was conducted to evaluate the THMFP in seven different drinking water sources in the vicinity of Kalpakkam, a rural township, on the east coast of India. Water from seven stations were analysed for THMFP. THMFP was compared with surrogate parameters such as dissolved organic carbon (DOC), ultraviolet absorbance ($UV_{254}$) and bromide. The data showed that THMFP was high in water from open wells as compared to closed bore wells, possibly due to more photosynthetic activity. Proximity to sea, and consequently the levels of bromide, was an important factor that influenced THM formation. THM surrogate parameters showed good correlation with THMFP.

Ultrafiltration of Humic and Natural Water: Comparison of Contaminants Removal, Membrane Fouling, and Cleaning (휴믹산 용액 및 자연수의 한외여과: 제거율, 막오염 및 세척특성 비교)

  • Choo, Kwang-Ho;Nam, Mi-Yeon
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.65-74
    • /
    • 2008
  • NOM and fine particles are the main target materials in water treatment using membranes. Particularly, humic substances extracted from soils are frequently used in many fundamental studies representing natural organic matter in raw water for drinking water treatment. In this study, ultrafiltration (UF) of artificial humic water and natural river water was conducted and the characteristics of removal efficiency and permeability were compared. In the UF of river water, the transmembrane pressure increased in the same pattern with that of 5 mg/L humic water. For the removal of organic matter and fine particles, however, two types of feed water had shown different trends. Kaolin particles and humic acids added to artificial water were better removed, while colloids and organics in natural water were relatively poorly removed. From the $UV_{254}$ and GPC analyses, it seemed that the hydrophobicity and size of humic substances contributed to the greater removal of organic matter. The UF membrane applied for humic water also showed a higher flux recovery by caustic chemical cleaning than that for river water.