• 제목/요약/키워드: natural evaporation

검색결과 150건 처리시간 0.023초

가열된 평판위에 매달려 있는 액적의 음향공진에 의한 열 및 물질 전달 촉진에 관한 연구 (Heat and Mass Transfer Enhancement of a pendant droplet on heated horizontal surface by acoustic resonance)

  • 문종훈;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.335-340
    • /
    • 2005
  • Nonlinear and forced oscillations of supported viscous droplet were focused in the present study. The droplet has a free contact line with solid plate and inviscid fluid. Natural frequencies of a pendant droplet have been investigated experimentally by imposing the acoustic wave while the frequency is being increased at a fixed amplitude. The evaporation was observed at atmosphere pressure. The droplet was recorded throughout the entire evaporation process and transient variations of the volume was measured. The evaporation process of oscillating droplet with thermofoil has been also observed to investigate analyzing the resonance effect on the thermal characteristics of droplet. It is found that a pendant droplet shows the resonant behaviors at each mode similar to the theoretical analysis. During imposing the acoustic wave, the pendant droplet makes a rotating motion in its longitudinal axis which is a new shape oscillation mode. The evaporation rate of a pendant droplet at resonant frequency is significantly enhanced.

  • PDF

Evaporation Heat Transfer Characteristics of Hydrocarbon Refrigerants R-290 and R-600a in the Horizontal Tubes

  • Roh, Geon-Sang;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.74-83
    • /
    • 2007
  • This paper presents the experimental results of evaporation heat transfer coefficients of HC refrigerants (e.g. R290 and R600a). R-22 as a HCFCs refrigerant and R-l34a as a HFCs refrigerant in horizontal double pipe heat exchangers, having four different inner diameters of 10.07, 7.73, 6.54 and 5.80 mm respectively. The experiments of the evaporation process were conducted at mass flux of $35.5{\sim}210.4 kg/m^2s$ and cooling capacity of $0.95{\sim}10.1 kW$. The main results were summarized as follows : The average evaporation heat transfer coefficient of hydrocarbon refrigerants(R-290 and R-600a) was higher than the refrigerants, R-22 and R-l34a. In comparison with R-22 the evaporation heat transfer coefficient of R-l34a is approximately $-11{\sim}8.1 %$ higher. R-290 is $56.7{\sim}70.1 %$ higher and R-600a is $46.9{\sim}59.7 %$ higher. respectively. In comparison with experimental data and some correlations, the evaporation heat transfer coefficients are well predicted with the Kandlikar's correlation regardless of a type of refrigerants and tube diameters.

액체수소 저장용기의 와류 구조 억제 및 증발률 저감을 위한 측벽 rib 설계 (Design of Sidewall Ribs for Suppressing Vortex Structures and Reducing Evaporation Rate in Liquid Hydrogen Storage Tank)

  • 김병건;김현기;박윤정;임민규;박성우;황진율
    • 한국가시화정보학회지
    • /
    • 제22권2호
    • /
    • pp.11-19
    • /
    • 2024
  • We performed numerical simulations on a C-type liquid hydrogen (LH2) storage tank for commercial vehicles to reduce evaporation rates by manipulating vortical structures. Owing to external heat, natural convection occurs inside the tank, leading to the enhanced evaporation of LH2. We observed that the regions of high magnitude vorticity correlate with those of high evaporation rates. Specifically, vortical structures in the side section area show higher vorticity magnitude and evaporation rates compared to those in the midsection area. To suppress these vortical motions, we installed an array of ribs at intervals corresponding to the mean diameter of the vortical structures. As a result, the area occupied by vortical structures in the side section area decreased, leading to a reduction in evaporation speed by approximately 2.3 times. This study elucidates the internal evaporation mechanism in storage tanks from the perspective of flow structures and potentially contributes to minimizing the boil-off rate in cryogenic storage tanks.

Mitigating the Urban Heat Island Phenomenon Using a Water-Retentive Artificial Turf System

  • Tebakari, Taichi;Maruyama, Tatsuya;Inui, Masahiro
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.91-100
    • /
    • 2010
  • To investigate the thermal properties of a water-retentive artificial turf system (W-ATS), we estimated hydrologic parameters including thermal conductivity, heat capacity, and surface albedo for both the W-ATS and natural grass. We used a model experiment to measure surface temperature and evaporation for both the W-ATS and natural grass. We found that the W-ATS had lower thermal conductivity than natural grass did, and it was difficult for the W-ATS to convey radiant heat to the ground. Compared to natural grass, the W-ATS also had lower heat capacity, which contributed to its larger variation in surface temperature: the W-ATS had higher surface temperatures during daytime and lower surface temperatures during nighttime. The albedo of the W-ATS was one-quarter that of natural grass, and reflected shortwave radiation from the W-ATS surface was lower than that from the surface of natural grass. These results indicate that the W-ATS caused the soil temperature to increase. Furthermore, evaporation from the W-ATS was one-quarter the value of evapotranspiration from natural grass.

  • PDF

DME FPSO선박의 탱크해석 및 Rolling 유동에 따른 증발 실험연구 (Analysis for DME FPSO Storage Tank and Experimental Study on the DME Evaporation Rate by Rolling Motion of Ship)

  • 윤상국;조원준;백영순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1010-1015
    • /
    • 2012
  • DME는 천연가스로부터 합성할 수 있는 대량의 에너지원이 된다. 한국가스공사는 DME 상업규모의 생산플랜트를 개발하고 이의 국내 공급을 위해 해외 자원 확보를 추진하고 있다. 본 논문은 응력과 변형 해석을 통하여 DME저장탱크의 설계기준을 제공하였고, DME FPSO저장탱크의 증발현상을 파악하기 위하의 증발을 발생시키는 원인인 열유입과 선박의 유동에 따른 증발량 실험을 수행하였다. 실험결과, 롤링의 각도가 커지고 액체 충전량이 많을수록 증발량이 증가하였다. 롤링각도가 15도 일 때의 증발량은 정지상태의 열유입 만에 의한 증발량 보다 약 20%가 증가하였다.

수평관내의 $CO_2$의 증발 열전달에 관한 연구 (Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube)

  • 장승일;최선묵;김대희;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

서울시 일원의 약수터 수질특성에 관한 연구 (A study on the charateristic of Natural Spring Water Quality in Seoul)

  • 김익수;권승미;이지영;김주형;이재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.57-59
    • /
    • 2002
  • Because of the growing demand for protect and maintain one's health, population search for good water increase very rapid in recent. This study was performed to investigate the at 432 sites natural spring water quality in Seoul. Samples for analysis were collected form January to December in 2001. The quality of water was evaluated by analyzing fourty items of Korea drinking water criteria. The main results of this study were as follows 1. The rate of natural spring water was 26.6% and the Total colony, E.Coli and Yersinia of the total incongruence cause was 67.9% 2. The distribution of phisical-chemical item on the incongruence cause was Residues on evaporation 8.6%, Turbidity 4.3%, Nitrate nitrogen 2.5%, pH 2.5% and F-1,2% 3. The most population area of mean drinking population per one day was that man of Gangnam was 312.92 person. Next to Yangcheon Seocho Seodaemun and Dongjak was 229.6, 195.31, 190.50, 190,00 person. 4. The more person and the number of natural spring water, the more non passed drinking criteria natural spring water except for Gangnam and Gangbuk. 5. The corelationship of drinking population and results of the tests do not exist and the corelationship of results and Total colony, E.Coli, Color, Turbidity, KMNO4 consumption, Residues on evaporation, Fe, Mn, Zn and A1 are existed positive relationship.

  • PDF

공기유입시스템에서의 섬유매체에 의한 방사성액체폐기물 처리에 관한 연구 (A Study on the Treatment of Radioactive Liquid Wastes using Synthetic textile by Air Intake System)

  • 김태국;이영희;안섬진;손종식;홍권표
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.101-104
    • /
    • 2003
  • 저준위 방사성액체폐기물 처리방법으로 에너지 소모가 적은 경제적이고 효율적인 처리방법을 제시하기 위하여 면 과 Polyester 가 함유된 합성섬유를 증발매체로 하여 자연기상 상태의 건조한 공기를 유입하여 방사성 액체폐기물과 접촉시켜 증발하는 연구를 하였다. 본 연구에서는 자연상태의 공기를 강제 유입시켜 액체의 증발현상, 증발매체표면에서의 물질전달 등 이론을 토대로 방사성액체폐기물을 처리하는 연구를 수행하였다. 실험은 방사성폐액을 직접 사용하였으며, 증발에 영향을 미치는 변수에 따라 증발 단위 면적당 방사성 폐액의 증발량측정 및 제염계수를 조사하였다. 증발효과는 유입공기의 습도가 낮고 공기의 유속과 공급액의 유량이 증가하고 폐액의 온도가 높아질수록 증발량이 증가하였다. 실험결과 습도는 70% 이하, 공급폐액의 유량이 $3.4{\ell}/hr\cdotm^2$ 이상, 공기유속은 1.14~l.47 m/sec 범위가 조업조건이며, 이때 제염계수는 $5.1{\times}10^3$, 배출공기의 방사능 농도는 $4.7{\times}10^{-13}{\mu}Ci/\textrm{m}{\ell}{\cdot}air$로 측정되었다. 공급유량이 $4.6{\ell}/hr\cdotm^2$와 공기유속이 1.47 m/sec일때 최대 증발조건으로 확인되었으며 대기의 온.습도 및 풍속에 따른 실험을 통하여 달톤형의 증발식 Air factor $[\textit{Eh}=(0.018 + 0.0141\textitv) {\delta}textitH]$를 도출하였다.

  • PDF

김치냉장고 내의 유동 및 열전달 특성에 관한 수치해석 (A Numerical Study on the Flow and Heat Transfer Characteristics in a Kimchi Refrigerator)

  • 윤준원
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1078-1087
    • /
    • 2003
  • Kimchi refrigerator is a household electric appliance developed with the wholly domestic technology for maturing and keeping kimchi. However, the principle of keeping is not yet revealed obviously. This numerical study has been conducted to investigate the flow and heat transfer characteristics in a kimchi refrigerator. The effects of arrangement variation of a evaporation tube are examined. Also, the heat transfer characteristics through the insulation material are discussed in detail. The flow and temperature field was simulated using the commercial code of CFX-5.3. A natural convection flow is formed through about 5/6 region from the bottom within the keeping space and accordingly, the 90% region of kimchi containers satisfies the temperature requirement with 0$\pm$0.5$^{\circ}C$. The stagnant flow exists in the upper 1/6 region of the keeping space and accordingly, the stratified high temperature distributions appear in the upper region of kimchi containers. The upward shift of the start location of a evaporation tube improves the temperature concentration toward $0^{\circ}C$ but the pitch variation is of no effect. The heat fluxes on the insulation surfaces show two-dimensional distributions with being higher toward the center. Through the variation of insulation thickness, 3.5% saving of insulation material is obtained under the same heat transfer rate.