• Title/Summary/Keyword: myocardial perfusion SPECT

Search Result 138, Processing Time 0.024 seconds

Pulling Bowstring of Gated Myocardial SPECT (게이트 심근 SPECT : 도약을 위한 준비)

  • Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.433-435
    • /
    • 1998
  • Recent progress of technology permits us to assess ventricular function and wall motion as well as myocardial perfusion using electrocardiographic gated myocardial perfusion single photon emission computed tomography (GM-SPECT). It is interesting that echocardiography and magnetic resonance imaging are moving in the same direction with the use of contrast medium to assess myocardial perfusion. A valid fundamental basis for a new technology is essential for a successful competition. Lee et al. report in this issue the reproducibility of serial measurement of left ventricular function including systolic wall thickening using a novel statistical method. It has important implications such as nitroglycerin or dobutamine application during GM-SPECT. The field of nuclear cardiology must continue to strive toward more sophisticated but straightforward evaluation of cardiac diseases.

  • PDF

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning (게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Park, Hun-Sik;Lee, Jae-Tae;Chae, Shung-Chul;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • Purpose : Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Materials and Methods : Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV election fraction (LVEF) was $\geq5%$ lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1 %(non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Results : Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs. 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs. 9.2%, p=0.029; severity 13.5 vs. 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis ($80{\sim}99%$) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Conclusion : Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than patients without post-stress LV dysfunction. All of the patients without perfusion defect in stunning group had significant coronary artery stenosis and needed revascularization. Therefore, we suggest that invasive diagnostic procedures and therapeutic interventions might be needed in patients with post-stress LV dysfunction.

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

The Correlation Analysis of Stress/Rest Ejection Fraction of $^{201}Tl$ Gated Myocardial Perfusion SPECT ($^{201}Tl$ 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Shim, Dong-Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.3-9
    • /
    • 2009
  • Purpose: It is well-known that stress-induced stunning and reversible perfusion defect have impact on ejection fraction (EF) when performing myocardial perfusion SPECT. Due to these reasons, gated SPECT is recommended at stress and rest studies. And there was many experiments to analyze between Stress and Rest EF by using $^{99m}Tc$-MIBI. The aim of this study is to analyze between stress EF and rest EF at myocardial perfusion SPECT by using $^{201}Tl$ and define possible predictors of EF variability. Materials and Methods: From 2008 June to 2009 February, we analyzed 144 patients undergoing $^{201}Tl$ gated myocardial perfusion SPECT in ASAN medical center. To analyze the data, we use QGS (Quantitative gated SPECT) software, and derived End-systolic volume (ESV), End-diastolic volume (EDV), EF from the result. In this study, we comparatively analyzed stress/rest EF correlation based on stress/rest EF, EDV, ESV and reversibility of myocardial perfusion defect by using paired t-test, Bland-Altman analysis. Results: Mached pairs of stress EF and rest EF demonstrated excellent correlation (r=0.92) with no statistically significant difference (p=0.11). Bland-Altman analysis demonstrated a mean ${\Delta}EF$ was 0.52% (95% confidential interval[CI], -1.17~0.12%). No statistically significant difference between a mean ${\Delta}EF$ and hypothetic mean of 0 (${\Delta}EF$=0) (p=0.10). In the correlation of ${\Delta}EF$ according to stress/rest EDV and ESV, except rest ESV of <28mL (p<0.05), there was no statistically significant difference. In the correlation of ${\Delta}EF$ according to reversibility of perfusion defect, patients with reversible perfusion defect has statistically significant difference of ${\Delta}EF$ (p<0.05). ${\Delta}EF$ of stress/rest EF showed no statistically significant difference except 55% of rest EF (p<0.05). Conclusion: Like studies with $^{99m}Tc$-MIBI, there was generally no statistically significant difference between stress and rest EF in this study results. However a stress EF of <55%, a rest ESV of <28mL and patients with reversible perfusion defect showed statistically significant difference in ${\Delta}EF$. If performing $^{201}T$ myocardial perfusion SPECT to patients with abnormal cardiac function or reversible perfusion defect, consider this study results and apply it. We expect this study results could be useful predictors of ${\Delta}EF$ variability.

  • PDF

Evaluation of Result of Coronary Artery Bypass Graft Surgery by Using Pre and Postoperative Myocardial SPECT (관동맥우회술 전후의 심근 SPECT를 이용한 수술 결과의 평가)

  • 이장훈;한승세
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1083-1091
    • /
    • 1997
  • This study was purposed to assess the result of coronary artery bypass graft surgery by analyzing and comparing the pre and postoperative myocardial perfusion state quantitatively by using myocardial SPECT. Twenty patients who received coronary artery bypass graft surgery since 1993 underwent both preoperative and postoperative myocardial SPECT and the result were analyzed. The mean age was 56.4$\pm$9.0 years, and the patients were composed of thirteen males and seven females. For quantitative analysis, we used polar maps of SPECT generated by Cedars-Sin i Medical Center program and we calculated perfusion scores, ischemic myocardial area ratios and reperfusion scores from polar maps. Preoperative mean stressfrest perfusion score was 7.3$\pm$ 1.117.7$\pm$ 1.0 and postoperative score was 8.1 $\pm$ 1 118.3$\pm$ 1.1. Preoperative mean stress ischemic myocardial area ratio was 0.32$\pm$0.2 and postoperative ratio was 0.15 $\pm$0.1. Postoperative mean perfusion score was significantly increased but, on the other hand, mean ischemic myocardial area ratio was significantly decreased as compared with preoperative values(p<0.01). Preoperative mean perfusion score of patients with postoperative roper(usion score more than 1.5 was significantly higher(p<0.01) than that of patients with postoperative reperfusion score less than 1.5. Preoperative perfusion scores of coronary artery territories that had fixed perfusion defect at myocardial SPECT were significantly low(4.3 $\pm$0.514.6$\pm$0.6, stresslrest), nevertheless it proved quantitatively that there was improvement in myocardial perfusion after surgery by showing improved perfusion scores postoperatively. In conclusion, myocardial SPECT is useful method for quantitative analysis of the myocardial perfusion state after coronary artery bypass grafting surgery.

  • PDF

Abnormal Perfusion on Myocardial Perfusion SPECT in Patients with Wolff-Parkinson-White Syndrome (Wolff-Parkinson-White 증후군 환자의 심근 관류 이상)

  • Kang, Do-Young;Cha, Kwang-Soo;Han, Seung-Ho;Park, Tae-Ho;Kim, Moo-Hyun;Kim, Young-Dae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • Purpose: Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkinson-White) syndrome. Materials and Methods: Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECG with Fitzpatrick's algorithm or electrophysiologic study and radiofrequency catheter ablation. Results: Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients (mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent ($11.0{\pm}8.5%$, range:$3{\sim}35%$) and mild to moderate severity ($-71{\pm}42.7%$, range:$-2l7{\sim}-39%$) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patient with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Conclusion: Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but it did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

State of the Art of Imaging Equipment and Tools for Nuclear Cardiology (심장핵의학 검사를 위한 영상장비 및 도구의 최신동향)

  • Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.165-173
    • /
    • 2009
  • Nuclear cardiology in Korea is less active, compared to nuclear oncology, but it has been specialized and ramified. Lately, sophisticated nuclear cardiac imaging methods provide more convenience for patients. It is necessary to accurately estimate the recent progress in the imaging devices for nuclear cardiology. Myocardial perfusion imaging is a well established study to evaluate heart function. Myocardial perfusion SPECT and PET have been used for assessment of coronary artery disease with various radiopharmaceuticals. And of late, the development of advanced imaging devices - multi-pinhole technique and high definition imaging technique - and software made the scanning time shorter and expanded the application field. Therefore, it is required to review the nuclear cardiology hardware/software for the clinical practice and research. In this review, the characteristics about recently-developed SPECT/PET and software for nuclear cardiology are described. It is hoped that this information would contribute to improving the activity of nuclear cardiac research in Korea where the research for the fusion imaging combining a and nuclear imaging is drawing more attention.