• Title/Summary/Keyword: muscular efficiency

Search Result 26, Processing Time 0.023 seconds

Market Survey and Motion Characteristics Research on Fitness Compression Wear to Improve Muscle Efficiency for the Elderly (고령자 근효율 향상을 위한 피트니스 압박웨어 시장조사 및 동작특성 조사)

  • Jeon, Eun-Jin;You, Hee-Cheon;Kim, Dong-Mi;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.20 no.3
    • /
    • pp.343-352
    • /
    • 2018
  • The objective of this study is to investigate the market of fitness compression wear as well as to design an optimal fitness compression wear by analyzing the muscle and movement characteristics of the elderly women in Korea. In this regard, research for functional garments is needed to increase muscle activity of elderly people during physical exercise. Firstly, we investigated the brand, design, size, material, and pattern of fitness wear based on the market survey. Secondly, we identified preference, evaluation items, evaluation method, and pattern design method based on the literature review. Finally, in addition, the motion type, range, angle to improve the muscle strength of the elderly were investigated and the maximum muscle strengths of each motion were analyzed by using 2007 Size Korea data (n = 386). It is also designed for muscle fatigue through exercise and rapid fatigue recovery after exercise. The evaluation methods for fitness compression wear were classified as motor functionality, physiological comfort, pattern and material suitability evaluations. The muscle strength at leg (pushing force) and waist (lifting force) of the ages of 60 to 69 years old showed 239.3 N and 274.5 N, respectively, which were the lowest forces compared to younger age groups. By applying these results to the design process of fitness wear, it is anticipated that the fitness wear will have a proper fit to the body shape of elderly people in South Korea as well as it can increase muscle efficiency to promote physical capability and healthy life for senior people.

Cellular Uptake and Transfection Efficiency of Plasmid DNA Using Low Molecular Weight Polyethylenimine (저분자량 폴리에틸렌이민을 이용한 유전자 송달 및 발현 유효성 연구)

  • Jeong, Gil-Jae;Park, Kui-Lye;Shin, Ji-Young;Choi, Han-Gon;Oh, Yu-Kyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.4
    • /
    • pp.263-267
    • /
    • 2004
  • Branched and linear polyethylenimines (PEIs) have been studied as efficient and versatile agents for gene delivery in vitro and in vivo. PEIs exist in a linear or branched topology and are available in a wide range of molecular weight (Mw). Most studies have been done using PEIs with Mw higher than 10Kd. This study was aimed to test the transfection efficiency and the cell viability following gene delivery using PEI of Mw 2Kd, a relatively lower Mw cationic polymer. We used murine interleukin-2(mIL-2) plasmid DNA complexed with branched PEI 2Kd or 25Kd, and transfected them into a myoblast muscle cell line, C2C12. The cellular uptake of mIL-2 plasmid DNA was determined using quantitative polymerase chain reaction. RNA transcript levels were studied in the myoblast cells. Our results show that PEI 2Kd was as effective as PEI 25Kd in celluar gene delivery and transfection efficiency in C2C12 cells. Moreover, MTT assay indicated that PEI 2Kd/DNA complexes did not significantly reduce the cell viability regardless of N/P ratios. These results suggest that PEI of Mw 2Kd might play a role as effective and low toxic nonviral vector systems for muscular cell lines.

Comparative Study of Biomechanical Left and Right Elbow Joint Extension Movements After Wheel Axle Application (윤축을 적용한 좌·우 주관절 신전 동작의 운동역학적 비교 연구)

  • Kim, Sung-Joo
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.429-436
    • /
    • 2011
  • In this study, we have experimented with 9 players at the national delegate level. Although there were some differences in the average effects of 3 types of one-two straight movements after the application of wheel axle, there were no statistical differences in the case of surface reacting forces, electromyograms, and impact forces. When the right fist was impacted using the one-two straight movements and the wheel axle was applied with 3 segmentations, high impact forces were obtained for the pronation in the following order-72.01 $m/s^2$ (type 2), 70.93 $m/s^2$ (type 3), and 58.19 $m/s^2$ (type 1). Higher values of the surface reacting force were found for type 1 that did not exhibit pronation in the left foot, whereas in the case of the vertical direction of the right foot, type 2 with pronation exhibited higher values and impact forces. In the right electromyogram, high impact forces due to the activation of the muscular electric potential were obtained for lumbar erector (LE) spinae and triceps brachii (TB) with type 1; LE spina, latissimus dosi (LD), and upper trapezius (UT) with type 2; and brachioradialis (BR), UT, and rectus abdominal (RA) with type 3. Due to pronation and complex motions of the 3 pronation segmentations, the efficiency was higher for impacts due to one-two straight movements.

Studies on the Effective Drug Delivery System Using Naked Plasmid DNA for the Erythropoietin Expression in vivo

  • Park, Yeong-Seop;Jeong, Dong-Geon;An, Jin-Ho;Choe, Cha-Yong;Ju, Hyeon
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.582-586
    • /
    • 2003
  • There has been interest in developing gene therapy based on naked plasmid DNA for treating serum protein deficiencies and human erythropoietin (hEPO) is one of the candidate for gene therapy being Investigated most enthusiastically. We constructed novel plasmid DNA vectors pVAC-hEPOI/II/III which contain one, two, three hEPO gene(s) respectively for producing high level expression and secretion of hEPO in vitro and in vivo. NIH3T3 and COS7 cells were transfected transiently with these vectors and increase in hEPO expression in medium reached 2-5 fold in comparison with pSecTagB-hEPO. Intra muscular administrations of pVAC-hEPOI/II/III vectors into mice resulted in high level secretion of hEPO in the serum and corresponding increases in hematocrit level. In conclusion the transduction efficiency of naked plasmid vectors is one of the critical factors of a gene delivery system and these novel plasmid vectors will contribute to various gene therapy based on naked plasmid DNA.

  • PDF

WalkON Suit: A Wearable Robot for Complete paraplegics (WalkON Suit: 하지 완전마비 장애인을 위한 웨어러블 로봇)

  • Choi, Jungsu;Na, Byeonghun;Jung, Pyeong-Gook;Rha, Dong-wook;Kong, Kyoungchul
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.116-123
    • /
    • 2017
  • Wearable robots are receiving great attention from the public, as well as researchers, because its motivation is to improve the quality of lives of people. Above all, complete paraplegic patients due to spinal cord injury (SCI) might be the most adequate target users of the wearable robots, because they definitely need physical assistance due to the complete loss of muscular strength and sensory functions. Furthermore, the medical care of complete paraplegics by using the wearable robots have significantly reduced the mortality rate and improved the life expectancy. The requirements of the wearable robot for complete paraplegics are actuation torque, locomotion speed, wearing sensation, robust gait stability, safety, and practicality (i.e., size, volume, weight, and energy efficiency). A WalkON Suit is the wearable robot that has satisfied the requirements of the wearable robot for complete paraplegics and participated in the powered exoskeleton race of Cybathlon 2016. In this paper, configuration of the WalkON Suit, human-machine interface, gait pattern, control algorithm, and evaluation results are introduced.

Control Algorithm of the Lower-limb Powered Exoskeleton Robot using an Intention of the Human Motion from Muscle (인체근육의 동작의도를 이용한 하지 근력증강형 외골격 로봇의 제어 알고리즘)

  • Lee, Hee-Don;Kim, Wan-Soo;Lim, Dong-Hwan;Han, Chang-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.124-131
    • /
    • 2017
  • This paper present a novel approach to control the lower body power assistive exoskeleton system of a HEXAR-CR35 aimed at improving a muscular strength. More specifically the control of based on the human intention is crucial of importance to ensure intuitive and dexterous motion with the human. In this contribution, we proposed the detection algorithm of the human intention using the MCRS which are developed to measure the contraction of the muscle with variation of the circumference. The proposed algorithm provides a joint motion of exoskeleton corresponding the relate muscles. The main advantages of the algorithm are its simplicity, computational efficiency to control one joint of the HEXAR-CR35 which are consisted knee-active type exoskeleton (the other joints are consisted with the passive or quasi-passive joints that can be arranged by analyzing of the human joint functions). As a consequence, the motion of exoskeleton is generated according to the gait phase: swing and stance phase which are determined by the foot insole sensors. The experimental evaluation of the proposed algorithm is achieved in walking with the exoskeleton while carrying the external mass in the back side.

Development of the Power Assist System for High Efficiency and Lightweight Wearable Robot in Unstructured Battlefield (비정형화된 전장 환경에 활용 가능한 고효율-경량형 외골격 착용 로봇의 근력 보조 시스템 개발)

  • Huichang Park
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.313-323
    • /
    • 2023
  • The wearable robot system is designed to assist human skeletal and muscular systems for enhancing user's abilities in various fields, including medical, industrial, and military. The military has an expanding need for wearable robots with the integration of surveillance/control systems and advanced equipment in unstructured battlefield environments. However, there is a lack of research on the design and mechanism of wearable robots, especially for power assist systems. This study proposes a lightweight wearable robot system that provides comfortable wear and muscle support effects in various movements for soldiers performing high-strength and endurance missions. The Power assist mechanism is described and verified, and the tasks that require power assist are analyzed. This study explain the system including its driving mechanism, control system, and mechanical design. Finally, the performance of the robot is verified through experiments and evaluations, demonstrating its effectiveness in muscle support.

Improvement Characteristics of Bio-active Materials Coated Fabric on Rat Muscular Mitochondria

  • Lee, Donghee;Kim, Young-Won;Kim, Jung-Ha;Yang, Misuk;Bae, Hyemi;Lim, Inja;Bang, Hyoweon;Go, Kyung-Chan;Yang, Gwang-Wung;Rho, Yong-Hwan;Park, Hyo-Suk;Park, Eun-Ho;Ko, Jae-Hong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.19 no.3
    • /
    • pp.283-289
    • /
    • 2015
  • This study surveys the improvement characteristics in old-aged muscular mitochondria by bio-active materials coated fabric (BMCF). To observe the effects, the fabric (10 and 30%) was worn to old-aged rat then the oxygen consumption efficiency and copy numbers of mitochondria, and mRNA expression of apoptosis- and mitophagy-related genes were verified. By wearing the BMCF, the oxidative respiration significantly increased when using the 30% materials coated fabric. The mitochondrial DNA copy number significantly decreased and subsequently recovered in a dose-dependent manner. The respiratory control ratio to mitochondrial DNA copy number showed a dose-dependent increment. As times passed, Bax, caspase 9, PGC-$1{\alpha}$ and ${\beta}$-actin increased, and Bcl-2 decreased in a dose-dependent manner. However, the BMCF can be seen to have had no effect on Fas receptor. PINK1 expression did not change considerably and was inclined to decrease in control group, but the expression was down-regulated then subsequently increased with the use of the BMCF in a dose-dependent manner. Caspase 3 increased and subsequently decreased in a dose-dependent manner. These results suggest that the BMCF invigorates mitophagy and improves mitochondrial oxidative respiration in skeletal muscle, and in early stage of apoptosis induced by the BMCF is not related to extrinsic death-receptor mediated but mitochondria-mediated signaling pathway.

Comparison of the Foot Muscle EMG and Medial Longitudinal Arch Angle During Short Foot Exercises at Different Ankle Position

  • Yoon, Hyeo-bin;Kim, Ji-hyun;Park, Joo-hee;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.46-53
    • /
    • 2017
  • Background: The MLA is supported by both the abductor hallucis (ABH) and the extrinsic muscles. Insufficient muscular support may lower the MLA when the body's weight is applied to the foot. The short foot exercise (SFE) is effective in increasing the height of the MLA for people with flat feet. Most of the research related to the SFE has simply evaluated the efficiency of the exercise using enhanced ABH electromyography (EMG) activation. Since the tibialis anterior (TA), peroneus longus (PER), and ABH are all involved in supporting the MLA, a new experiment design examining the EMG of the selected muscles during SFE should be applied to clarify its effect. Objects: Therefore, this study aimed to clarify the effect of the SFE in different ankle position on the MLA angle and the activation of both the intrinsic and extrinsic muscles and to determine the optimal position. Methods: 20 healthy subjects and 12 subjects with flat feet were recruited from Yonsei University. The surface EMG and camera were used to collect muscle activation amplitude of TA, PER, and ABH and to capture the image of MLA angle during SFE. The subjects performed the SFE while sitting in three different ankle positions-neutral (N), dorsiflexion (DF) at 30 degrees, and plantar flexion (PF) at 30 degrees. Results: ABH EMG amplitudes were significantly greater in N and DF than in PF (p<.05). Muscle activation ratio of TA to ABH was the lowest in PF (p<.05). MLA angle in both groups significantly decreased in PF (p<.01). The TA and ABH was activated at the highest level in DF. However, in PF, subjects significantly activated the ABH and PER with relatively low activation of TA. Conclusion: Therefore, researchers need to discuss which SFE condition most effectively use the arch support muscle for flat foot.

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF