• Title/Summary/Keyword: multiple contrast

Search Result 563, Processing Time 0.023 seconds

New Construction for Visual Cryptography Using the Cumulative Matrix (누적행렬을 이용한 ( k, n) 시각암호의 새로운 구성)

  • 김문수;박지환
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.11 no.6
    • /
    • pp.15-26
    • /
    • 2001
  • Visual cryptography is a simple method in which secret information can be directly decoded in human visual system without any cryptographic computations. When the secret image is scattered to n random shares(slides), this scheme has some week point such as pixel expansion and contrast degradation. Therefore, it is necessary to reduce the pixel expansion and improve the contrast in recovered image. In this paper, we propose a new construction method for (k, n) visual cryptography using the cumulative matrix. In case k is odd, we can construct the cumulative matrix perfectly. For even k, the contrast of special pair in decoded image can be achieved best by permitting multiple contract. The proposed method is more simple than that of S. Droste\`s in construction and the average contrast of decoded image is improved for the most part. Also, we show that the basis matrices depending on the cumulative matrix are able to be applied for the general access structure.

An Optimized Multiple Fuzzy Membership Functions based Image Contrast Enhancement Technique

  • Mamoria, Pushpa;Raj, Deepa
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.3
    • /
    • pp.1205-1223
    • /
    • 2018
  • Image enhancement is an emerging method for analyzing the images clearer for interpretation and analysis in the spatial domain. The goal of image enhancement is to serve an input image so that the resultant image is more suited to the particular application. In this paper, a novel method is proposed based on Mamdani fuzzy inference system (FIS) using multiple fuzzy membership functions. It is observed that the shape of membership function while converting the input image into the fuzzy domain is the essential important selection. Then, a set of fuzzy If-Then rule base in fuzzy domain gives the best result in image contrast enhancement. Based on a different combination of membership function shapes, a best predictive solution can be determined which can be suitable for different types of the input image as per application requirements. Our result analysis shows that the quality attributes such as PSNR, Index of Fuzziness (IOF) parameters give different performances with a selection of numbers and different sized membership function in the fuzzy domain. To get more insight, an optimization algorithm is proposed to identify the best combination of the fuzzy membership function for best image contrast enhancement.

A Unified Theory of Spatial Sound and Vibration Control with Multiple Sources (음향 및 진동장의 형상을 제어하는 다양한 방법)

  • Kim, Yang-Hann;Choi, Joung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.126-132
    • /
    • 2006
  • In this paper, we aim to control the sound and vibration spatially, so that a desired physical variable is enhanced within a zone we select. This is somewhat analogous to have manipulators that can draw wave shape in any place we want. Brightness and contrast control have shown that such a manipulation is possible by controlling multiple sources[J.-W. Choi and Y.-H. Kim, J. Acoust. Soc. Am. 111(4), 2002]. In particular, the acoustic brightness control seeks a way to increase loudness of sound over a chosen area, and the contrast control aims to enhance loudness difference between two neighboring regions. This enables us to manipulate spatial distribution of sound by making two different kinds of zone ? the bright and dark zone- at the same time. The primary focus of this study is to unit the theoretical formulation of the brightness and contrast control and to find a link between these methods, as well as its relation to other conventional techniques. It is also shown that we can generate various shape of wave field by transforming the domain we consider.

  • PDF

Attentional modulation on multiple acoustic cues in phonological processing of L2 sounds

  • Hyunjung Lee;Eun Jong Kong
    • Phonetics and Speech Sciences
    • /
    • v.15 no.4
    • /
    • pp.11-16
    • /
    • 2023
  • The present study examines how a cognitive attention affects Korean learners of English (L2) in perceiving the English stop voicing distinction (/d/-/t/). This study tested the effect of attentional distractor on primary and non-primary acoustic cues, focusing on the role of Voice Onset Time (VOT) and fundamental frequency (F0). Using the dual-task paradigm, 28 Korean adult learners of English participated in the stop identification task carried with (distractor) and without (no-distractor) arithmetic calculation. Results showed that when distracted, Korean learners' sensitivity to VOT decreased as priorly reported with native English speakers. Furthermore, as F0 is a primary cue for a L1 Korean stop laryngeal contrast, its role in L2 English voicing distinction was also affected by a distractor, without compensating for the reduced VOT sensitivity. These findings suggest that flexible use of multiple cues in L1 is not necessarily beneficial for L2 phonological processing when coping with a adverse listening condition.

Preliminary study on contrast flow analysis of thoracic transforaminal epidural block

  • Hong, Ji Hee;Noh, Kyoung Min;Park, Ki Bum
    • The Korean Journal of Pain
    • /
    • v.31 no.2
    • /
    • pp.125-131
    • /
    • 2018
  • Background: The thoracic transforaminal epidural block (TTFEB) is usually performed to treat herpes zoster or postherpetic neuralgia (PHN). Especially, multiple segmental involvements and approximate contrast medium spread range, according to volume, help to choose the proper drug volume in the transforaminal epidural block. This study investigated the contrast medium spread patterns of 1-ml to 3-ml TTFEBs. Methods: A total of 26 patients with herpes zoster or PHN were enrolled in this study. All participants received 1 ml, 2 ml, or 3 ml of contrast medium. Results were divided into Groups A, B and C based on the volume (1, 2, or 3 ml), with n = 26 for each group. After the injection of contrast medium, the spread levels were estimated in both the lateral and anteroposterior (AP) images using fluoroscopy. Results: The cephalad spread of contrast medium in the lateral image as expressed by the median (interquartile range) was 2.00 levels (1.00-2.00) for Group A, 2.50 (2.00-3.00) for Group B, and 3.00 (2.00-4.00) for Group C. The caudal spread level of contrast medium was 1.00 (1.00-2.00) for Group A, 2.00 (2.00-3.00) for Group B, and 2.00 (2.00-3.00) for Group C. There was ventral and dorsal spread of the 3-ml contrast medium injection in 88% (23/26) of cases in the lateral image. Conclusions: Injection of 3 ml of contrast medium through the foramina spread 6 levels in a cephalocaudal direction. Spread patterns revealed a cephalad preference. TTFEB resulted in dorsal and ventral spread in a high percentage of cases. This procedure may be useful for transferring drugs to the dorsal and ventral roots.

Context-free multiple-object segmentation using attention operator based on modified generalized symmetry transform (일반화 대칭변환을 변형한 관심 연산자에 의한 사전 정보없는 다중 물체 분할)

  • 구태모;전준형;최흥문
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.4
    • /
    • pp.36-44
    • /
    • 1997
  • An efficient context-free multiple-object segmentation using attention operator based on modified generalized symmetry transform is proposed and implemented by modifying a radial basis function network. By using the difference of intensity gradient, instead of te intensity gradient itself, in generalized symmetry tranform so as to make the attention operator to preserve the edges of the objects shape, an efficient context-free multiple-object segementation is proposed in which no a priori shape informtion on the objects is requried. The attention operator is implemented by using a modified radial basis function network which can reflect symmetry, and by using te edge pyramid of the input image, both of the local and the global symmetry of the objects are reflected simultaneously to make the multiple-object with different sizes be segmented with a singel fixed-size $n\timesm$ can be done with O(n) complexity. The simulaton results show that the proposed algorithm can efficiently be used in context-free multiple-object segmentation even for the low contrast IR images as well as for the images from the camera.

  • PDF

Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering (대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

Comparing the Intelligibility of Spastic and Flaccid Types (경직형과 이완형 마비말장애의 명료도 비교)

  • Kim Soo-Jin
    • MALSORI
    • /
    • no.48
    • /
    • pp.1-17
    • /
    • 2003
  • Among the types of dysarthria, spastic and flaccid types are the most prominent manifestations. The objectives of the present research are (1) to discover the phonetic contrasts that differentiate spastic dysarthria from flaccid dysarthria, (2) to analyze the degrees of predictability of each phonetic contrast for intelligibility in spastic and flaccid dysarthrias and to compare them. The 'phonemic contrast word intelligibility pairs' for dysarthric speakers were tested and proved to be useful for clinical assessment of and research on dysarthria. In the group of spastic type, it showed that initial fricative vs. affricate and front vs. back vowel contrasts are transmitted relatively less effectively than flaccid type. In the group of flaccid type, initial glottal vs null contrast is transmitted less effectively than spastic type. The overall intelligibility of spastic dysarthria was predicted by multiple regression analysis with 88% accuracy by three phonetic contrasts(initial fricative vs. affricate; front vs. back vowels; initial consonant correlates). And the intelligibility of flaccid dysarthria was predicted by two phonetic contrasts(initial nasal vs. stop, front vs. back vowels) with 60% accuracy.

  • PDF

Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver

  • Kim, Yoon-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.1-16
    • /
    • 2019
  • Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.