• Title/Summary/Keyword: multi-use facility

검색결과 127건 처리시간 0.153초

거주자가 지각한 정신건강 관련 주거의 질 분석에 기초한 주거 개선요소 (Housing Improvement Elements Depended on the Analysis of Urban Residents' Perceived Korean Housing Quality Related to Mental Health)

  • 최병숙;박정아
    • 한국주거학회논문집
    • /
    • 제24권6호
    • /
    • pp.189-197
    • /
    • 2013
  • The purpose of the study was to analyze the improvement elements depended on housing quality measurement tool related to mental health. The data for the analysis was collected through questionnaire survey method from November 1, 2012 to January 17, 2013, and the sample consisted of 720 respondents living in single detached houses, multi-families detached houses, apartments, and town houses in 4 cities, Seoul, Busan, Daejeon, and Kwangju. The data were analyzed using descriptive statistics. The results of improvement elements are as follows: 1) Pedestrian-threaten street from cars in physical safety 2) A secluded or dark spot and fear of walking at night in social security, 3) Indoor noise, outdoor noise, and evidence of abandoned trash heap/bottle in neighborhood in health & sanitation, 4) Illegal parking and heating control system in facility convenience, 5) Extra kitchen, number of bathrooms, and community spaces in space convenience, 6) Openness and spaciousness of indoor room, and satisfaction of house and neighborhood in comfort, 7) Management common/sharing space in maintenance, 8) Energy saving facility and environment friendly materials use in sustainability, 9) Burden on housing cost, asset value on house, and school district in economic value, 10) Reflection of residents style, surrounding building's number of layers, and neighborhood appearance of preference in housing environment image.

ANALYSIS OF THE ISP-50 DIRECT VESSEL INJECTION SBLOCA IN THE ATLAS FACILITY WITH THE RELAP5/MOD3.3 CODE

  • Sharabi, Medhat;Freixa, Jordi
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.709-718
    • /
    • 2012
  • The pressurized water reactor APR1400 adopts DVI (Direct Vessel Injection) for the emergency cooling water in the upper downcomer annulus. The International Standard Problem number 50 (ISP-50) was launched with the aim to investigate thermal hydraulic phenomena during a 50% DVI line break scenario with best estimate codes making use of the experimental data available from the ATLAS facility located at KAERI. The present work describes the calculation results obtained for the ISP-50 using the RELAP5/MOD3.3 system code. The work aims at validation and assessment of the code to reproduce the observed phenomena and investigate about its limitations to predict complicated mixing phenomena between the subcooled emergency cooling water and the two-phase flow in the downcomer. The obtained results show that the overall trends of the main test variables are well reproduced by the calculations. In particular, the pressure in the primary system show excellent agreement with the experiment. The loop seal clearance phenomenon was observed in the calculation and it was found to have an important influence on the transient progression. Moreover, the collapsed water levels in the core are accurately reproduced in the simulations. However, the drop in the downcomer level before the activation of the DVI from safety injection tanks was underestimated due to multi-dimensional phenomena in the downcomer that are not properly captured by one-dimensional simulations.

어초어장으로 시설된 사각형어초의 수량 산정 및 유효공용적 평가 (Estimation of Countermeasures and Efficient Use of Volume of Artificial Reefs Deployed in Fishing Grounds)

  • 김호상;이정우;김종렬;윤한삼
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제12권3호
    • /
    • pp.181-187
    • /
    • 2009
  • 본 연구에서는 인위적인 어장 조성을 위해 해저에 시설된 사각형어초의 현존 상태 및 수량을 평가하고자 Multi-Beam Echo Sounder(MBES)와 Side Scan Sonar(SSS) 등의 조사에서 생산된 자료를 사용하여 단위어초의 부피, 산적 어초의 체적 및 공극률을 계산하고 이를 잠수조사 결과와 비교함으로써 단위어초(사각형 어초)의 현존 시설량 산정공식의 효율성을 검토하였다. 부산연안에 시설되어 있던 총 9곳의 사각형어초로 조성된 단위어초의 평균 유효공용적율 k값은 0.753이었으며 k값과 시설경과년수(year,Yr)와의 상관식은 k=0.0023Yr+0.725로 추정되었으나 그 상관성은 매우 낮은 것으로 나타났다. 따라서 인공어초 설치후 시간이 경과할 수 록 산적되어진 어초의 침하 또는 간극의 축소로 인해 다짐의 정도가 커지는 효과가 발생함에도 불구하고 어초의 시설 경과 연도와 k값과의 상관성은 낮았으며 이에 반해 해역의 저질 조건 및 초기 시설 당시의 설치조건에 따라서 k값이 달라 질수 있음을 알 수 있었다.

  • PDF

Preliminary Investigation for Feasibility of Wave Energy Converters and the Surrounding Sea as Test-site for Marine Equipment

  • Park, Jin-Yeong;Baek, Hyuk;Shim, Hyungwon;Choi, Jong-Su
    • 한국해양공학회지
    • /
    • 제34권5호
    • /
    • pp.351-360
    • /
    • 2020
  • Of late, demand for test sites for marine equipment such as ASV, AUV, ROV, and various underwater sensors is increasing. The authors have focused on an oscillating water column (OWC), which is being constructed near Chagwido Island Jeju, as one of the test-sites. The main objective of the OWC is to produce wave energy and develop technologies. It has been built in the sea approximately 1 km off the coast. It has berth accommodation and some rooms that can be used as laboratories. To investigate the feasibility of its usage as a test site for marine equipment, we acquired bathymetric data around the OWC by using a multi-beam echo sounder and a single-beam scanning sonar. The accessibility of the OWC from nearby ports and the use of support vessels or ships were also investigated. 3D point cloud data from the multi-beam echo sounder and 2D acoustic images from the scanning sonar are expected to be used as references for identifying changes over time. In addition, through these experiments, we derived a procedure to use this facility as a test site by using the IDEF0 functional modelling method. Based on this preliminary investigation and previously reported examples, we determined the general conditions and preferences for evaluating the performance of various marine equipment heuristically. Finally, we developed five applications that were derived from this investigation.

민간경비원의 응급처치 교육에 대한 실태조사 (The Private Security Officer ' Actual Condition of First-Aid Education)

  • 김현호;강현
    • 시큐리티연구
    • /
    • 제51호
    • /
    • pp.275-290
    • /
    • 2017
  • 1976년 용역경비업법이 제정된 이후 우리나라의 민간경비산업 또한 괄목할 만한 성장을 하였고, 더불어 민간경비원의 다양한 역할이 요구되어지고 있다. 민간경비원은 다중이용시설에 이용자들의 최초접촉자(first contactor)로서 어떠한 사건 사고가 발생하였을 때 가장 먼저 사고 현장상황을 파악하고 대처해야 하며, 응급의료진이 오기 전까지는 가능한 범위 안에서 응급처치를 시행하여야 한다. 그러나 시설이용자들의 안전을 책임지고 있는 민간경비원의 응급처치 교육은 현저히 부족한 실정이라고 사료된다. 따라서 본 연구에서는 첫째, 민간경비원들의 직무 및 응급처치 교육 횟수를 알아보고, 교육 횟수가 응급처치 능력에 어떠한 영향을 미치는지 알아본다. 둘째, 민간경비원들의 응급처치 교육 만족도가 응급처치 능력에 미치는 영향을 살펴볼 필요가 있다고 사료된다. 이와 같은 목적을 위하여 수도권에서 근무하고 있는 민간경비원을 대상으로 응급처치능력에 대한 설문조사를 실시하였다. 자료 분석을 위해서 Stata se/ 14.0ver 을 사용하였으며, 타당도 및 신뢰도분석을 위해 탐색적 요인분석과 Cronbach's a 값을 도출하였다. 응급처치교육의 실태를 살펴보기 위해서 빈도분석, 집단 간 차이분석과 다중회귀분석을 실시하였다. 자료 분석 결과 민간경비원에 대한 직무교육 및 응급처치교육 횟수가 부족 현저히 부족하다는 것을 확인하였으며, 직무 및 응급처치교육의 횟수에 따라서 응급처치교육 만족도 및 응급처치능력에 차이가 있다는 것을 알 수 있었다. 또한, 응급처치 교육만족도가 응급처치능력에 부분적으로 영향을 미치는 것으로 나타났다.

  • PDF

다중밀집시설 대형화재 외부대피 체계에 관한 연구 (A Study on the External Evacuation System for Large-scale Fire of Multi-use Facilities)

  • 김정곤;정민수;정재욱
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.129-145
    • /
    • 2022
  • 연구목적: 본 연구는 다중밀집시설에 대형화재가 발생하는 경우 건물 외부에서 발생 가능한 여러 상황을 상정 및 이에 대한 대응절차 및 행동요령을 제시함으로써 효율적인 화재대응을 위한 외부 대피체계를 마련하고자 하였다. 연구방법: 화재 시 외부에서 발생 가능한 여러 상황 및 화재 매뉴얼 구성인자 등을 고려하여 필요한 사항들을 정리하였다. 이를 위해 화재 발생 위험경보 기준, 건물 재실자 역할 구분 등의 주요 인자의 제시 및 필요사항을 정리하였다. 또한, 화재 관련 외부대피소의 정의 및 외부 대피경로에 대해 제시하였으며, 다중밀집시설 중에서 중구의 노후아파트를 대상으로 외부대피소 및 외부대피경로 등에 대한 적용성을 검토하였다. 연구결과: 조사 및 분석 결과를 종합하여 4단계(관심, 주의, 경계, 심각) 화재위험경보 기준을 설정하고, 재실자, 시설 소유자, 거주자, 관리자, 소방책임자에 대한 행동요령을 정리하여 제시하였다. 또한, 외부대피소의 개념과 역할에 대하여 1차~3차 대피소로 구분하여 각 대피소의 정의 및 대피경로 설정에 관한 사항을 제시하고 이에 대하여 고찰하였다. 결론: 본 연구를 통해 화재 시에 무질서하고 통제가 어려운 건물 외부 공간에 대하여, 대피자 안전확보를 위한 체계화 방안을 제시한 것으로서 의미를 가지며, 화재시 건물 내부 및 외부의 통합적인 매뉴얼 작성에 활용성을 가질 것으로 판단하였다.

Economic Evaluation of Coupling APR1400 with a Desalination Plant in Saudi Arabia

  • Abdoelatef, M. Gomaa;Field, Robert M.;Lee, YongKwan
    • 시스템엔지니어링학술지
    • /
    • 제12권1호
    • /
    • pp.73-87
    • /
    • 2016
  • Combining power generation and water production by desalination is economically advantageous. Most desalination projects use fossil fuels as an energy source, and thus contribute to increased levels of greenhouse gases. Environmental concerns have spurred researchers to find new sources of energy for desalination plants. The coupling of nuclear power production with desalination is one of the best options to achieve growth with lower environmental impact. In this paper, we will per-form a sensitivity study of coupling nuclear power to various combinations of desalination technology: {1} thermal (MSF [Multi-Stage Flashing], MED [Multi-Effect Distillation], and MED-TVC [Multi-Effect Distillation with Thermal Vapour Compression]); {2} membrane RO [Reverse Osmosis]; and {3} hybrid (MSF-RO [Multi-Stage Flashing & Reverse Osmosis] and MED-RO [Multi-Effect Distillation & Reverse Osmosis]). The Korean designed reactor plant, the APR1400 will be modeled as the energy production facility. The economical evaluation will then be executed using the computer program DEEP (Desalination Economic Evaluation Program) as developed by the IAEA. The program has capabilities to model several types of nuclear and fossil power plants, nuclear and fossil heat sources, and thermal distillation and membrane desalination technologies. The output of DEEP includes levelized water and power costs, breakdowns of cost components, energy consumption, and net saleable power for any selected option. In this study, we will examine the APR1400 coupled with a desalination power plant in the Kingdom of Saudi Arabia (KSA) as a prototypical example. The KSA currently has approximately 20% of the installed worldwide capacity for seawater desalination. Utilities such as power and water are constructed and run by the government. Per state practice, economic evaluation for these utilities do not consider or apply interest or carrying cost. Therefore, in this paper the evaluation results will be based on two scenarios. The first one assumes the water utility is under direct government control and in this case the interest and discount rate will be set to zero. The second scenario will assume that the water utility is controlled by a private enterprise and in this case we will consider different values of interest and discount rates (4%, 8%, & 12%).

전국 다중이용시설의 실내공기 부유 곰팡이의 현황 및 특성 분석 (An Analysis of the Current Status and Characteristics of Airborne Fungi in Indoor Air in Multi-Use Facilities Nationwide)

  • 박용성;권순현;박송이;기선호;윤원석
    • 한국환경보건학회지
    • /
    • 제48권5호
    • /
    • pp.282-289
    • /
    • 2022
  • Background: Airborne fungi are ubiquitous in the air and exposure to an airborne fungus can be a significant risk factor. The composition of fungi has been potentially important for human health, especially for respiratory diseases like asthma and atopic dermatitis. Therefore, we attempted to ascertain what kind of airborne fungi affect human health at a nationwide level. Objectives: This study was carried out to provide information on indoor fungi distribution at multi-use facilities throughout South Korea. Methods: We classified our data by region and public facility after collection, cultivation, and identification via the sequencing of the ITS (internal transcribed spacer) region. We investigated whether or not the proliferation of HaCaT cells was affected by the identified airborne fungi. Results: In our data, the most isolated airborne fungi by region were Penicillium spp (Seoul, Daegu), Periconia sp (Gyeonggi-do), Iprex sp (Gangwon-do), Phanerochaete sp (Busan), Bjerkandera sp (Gwangju), and Aspergillus sp (Jeju-do). In the public facilities, the most detected fungi were Cladosporium sp (public transport), Penicillium sp (apartment house, retail market, financial institution, karaoke room), Bjerokandera sp (underground parking lot, public toilet, medical institution), Periconia sp (retail store), and Fusarium sp (general restaurant). Next, we selected twenty airborne fungi to examine their cytotoxicity and proliferation of human skin cells. In this experiment, the proliferation of the cells was influenced by most of the identified fungi. In case of the cytotoxicity test, most genera except for Rhodotorula sp and Moesziomyces sp showed cytotoxicity in HaCaT cells. Conclusions: The distribution of mold in the indoor air in multi-use facilities in South Korea differs from region to region, and this is an indicator that should be considered in future health impact studies. In addition, as a result of culturing about 20 types of bacteria dominant in indoor air, it was found that most (90%) inhibit the growth of skin cells, which can be harmful to health. An in-depth study of the health effects of floating fungi is needed.

이기종 태양광 설비 지원을 위한 범용 RMC 게이트웨이 개발 (Development of General-Purpose Remote Maintenance Controller Gateway for Multi-Modal Photovoltaic Equipment)

  • 임수창;홍석훈;박철영;송법성;김종찬
    • 한국멀티미디어학회논문지
    • /
    • 제23권10호
    • /
    • pp.1307-1317
    • /
    • 2020
  • In recent years, the PV plant is gradually increasing in korea and has begun to focus on PV system O&M(Operation and Management). The legacy PV system can hardly be gathering realtime information. That is why it is difficult for the facility to respond immediately to situations in which problems arise. This leads to economic losses due to reduced power generation. In this study, we implemented an RMC(Remote Maintenance Control) gateway that supports multi-area equipment(inverters, junction boxes, switchboards, environmental sensors) that are not limited to specific manufacturers. It provides a function to visualize the collected data. Users can easily check the power generation and operation status of PV system equipment. In the future, we will develop an algorithm capable of analyzing beta factors that cause equipment performance degradation, parts aging, and deterioration using data collected from facilities. We intend to use this algorithm as a fundamental technology for O&M by transplanting it to the RMC gateway.

수요기반 환기량 조절법 (DCV)의 다중이용시설 적용방안 (The Use of Demand Controlled Ventilation in Multi-Purposed Facility)

  • 정재원;노상태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.111-116
    • /
    • 2008
  • The objective of this paper was to show the possibility of demand-controlled ventilation (DCV) using the current Korean ventilation standard for multi-purposed facilites. Two attractive DCV approaches; $CO_2$-DCV and RFID-DCV were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with enthalpy recovery device. A numerical model for predicting realtime occupant number, ventilation rate, and $CO_2$ concentration under given conditions was developed using a commercial equation solver program. It was found that the current ventilation standard causes unstable ventilation system control in DCV applications, especially under $CO_2$-DCV. It is because the ventilation rate (per person) used in Korea is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupant and building itself, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order for solving this problem, current Korean ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to DCV significantly.

  • PDF