• 제목/요약/키워드: motion artifact reduction

검색결과 24건 처리시간 0.027초

완전 데이터 적응형 MLS 근사 알고리즘을 이용한 Interleaved MRI의 움직임 보정 알고리즘 (Motion Artifact Reduction Algorithm for Interleaved MRI using Fully Data Adaptive Moving Least Squares Approximation Algorithm)

  • 남혜원
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.28-34
    • /
    • 2020
  • In this paper, we introduce motion artifact reduction algorithm for interleaved MRI using an advanced 3D approximation algorithm. The motion artifact framework of this paper is data corrected by post-processing with a new 3-D approximation algorithm which uses data structure for each voxel. In this study, we simulate and evaluate our algorithm using Shepp-Logan phantom and T1-MRI template for both scattered dataset and uniform dataset. We generated motion artifact using random generated motion parameters for the interleaved MRI. In simulation, we use image coregistration by SPM12 (https://www.fil.ion.ucl.ac.uk/spm/) to estimate the motion parameters. The motion artifact correction is done with using full dataset with estimated motion parameters, as well as use only one half of the full data which is the case when the half volume is corrupted by severe movement. We evaluate using numerical metrics and visualize error images.

독립 요소 분석을 통한 Photoplethysmography에서의 동잡음 제거 (The Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis)

  • 김경하;유선국;김병수;김남현
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권10호
    • /
    • pp.598-605
    • /
    • 2003
  • In this paper, we propose the method that separates PPG signal and motion artifact signal from two input signals using new independent component analysis algorithm in time domain. In order to eliminate the large level artifact efficiently, block interleaving. lowpass time filtering and innovation processing technique were applied in ICA preprocessing, and FastICA algorithm were applicable. Experiments are made with the numerical simulation and the real PPG signal including four kinds of motion artifact pattern. Our results show that ICA can effectively detect, separate and remove motion artifact in input signals. Then from the separated signals we restore the original PPG signal and propose a new method which computes SpO$_2$ using ICA mixing matrix.

Intra-Motion Compensation Using CSRS method in MRI

  • Ro, Y.M.;Yi, J.H.;Cho, Z.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.377-382
    • /
    • 1994
  • In the conventional Fourier imaging method in MRI (Magnetic Resonance Imaging), intramotion such as pulsatile flow makes zipper-like artifact along the phase encoding direction. On the other hand, line-integral projection reconstruction (LPR) method has advantages such as imaging of short T2, object and reduction of the flow artifact by elimination of the flow-induced phase fluctuation. The LPR, however, necessarily requires time consuming filtering and back-projection processes, so that the reconstruction takes long time. To overcome the long reconstruction time of the LPR and to obtain the flow artifact reduction effect, we adopted phase corrected concentric square raster sampling (CSRS) method and improved its imaging performance. The CSRS is a fast reconstruction method which has the same properties with the LPR. In this paper, we proposed a new method of flow artifact reduction using the CSRS method. Through computer simulations and experiments, we verified that the proposed method can eliminate phase fluctuations, thereby reducing the flow artifact and re- markably shorten the reconstruction time which required long time in the LPR.

  • PDF

가속도계를 이용한 광전용적맥파의 동잡음 제거 (A Study on Accelerometer Based Motion Artifact Reduction in Photoplethysmography Signal)

  • 강정훈;조백환;이종실;지영준;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.369-376
    • /
    • 2007
  • With the convergence of ubiquitous networking and medical technologies, ubiquitous healthcare(U-Healthcare) service has come in our life, which enables a patient to receive medical services at anytime and anywhere. In the u-Healthcare environment, intelligent real-time biosignal aquisition/analysis techniques are inevitable. In this study, we propose a motion artifact cancelation method in portable photoplethysmography(PPG) signal aquisition using an accelerometer and an adaptive filter. A preliminary experiment represented that the component of the pedestrian motion artifact can be found under 5Hz in the spectral analysis. Therefore, we collected PPG signals under both simulated conditions with a motor that generates circular motion with uniform velocity (from 1 to 5Hz) and a real walking condition. We then reduced the motion artifact using a recursive least square adaptive filter which takes the accelerometer output as a noise reference. The results showed that the adaptive filter can remove the motion artifact effectively and recover peak points in PPG signals, which represents our method can be useful to detect heart rate in real walking condition.

A Bilateral Filtering Based Ringing Elimination Approach for Motion-blurred Restoration Image

  • Wang, Weiqing;Wang, Weihua;Yin, Jiao
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.200-209
    • /
    • 2020
  • We describe an approach that uses a bilateral filter to reduce the ringing artifact in motion-blurred restoration image. It takes into account the specific physical structure of the ringing artifact combined with the properties of the human visual system. To properly reduce the ringing artifact, each of the adjacent pixels is limited in a straight line which has a given direction. To protect the edges and the texture regions of an image, our algorithm divides the image into texture regions and flat regions, and the artifact reduction algorithm is only applied to the flat region. Finally, we use 8 typical images and 5 objective quality evaluation indices to evaluate our algorithm. Experimental results show that our algorithm can obtain better results in subjective visual effect and in objective image quality evaluation.

산소포화도(SpO2) 측정시에 발생되는 motion artifact를 reduction하는 algorithm (Algorithm for reduction of motion artifact generated in SpO2 measurement)

  • 한승헌;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.860-863
    • /
    • 2003
  • 산소포화도 측정은 Beer-Lambert's law를 기초로하여 측정 부위(손가락, 귀 등)에 LED를 발광한 후 투과된 적생광과 적외선광 신호가 통과하고 photodetector에서 감지한 후 나타난 두 광의 비율로 계산한다. Pulse oximetry는 이러한 산소포화도를 측정하는 기기인데, 근데 아주 민감하기 때문에 압력이 적절한 조직 혈류로 공급하기 어려울 정도로 아주 낮을 때 펄스를 검출한다. 다시말해서, SpO2는 혈관 수축이나 저혈압에서의 흐르지 않는 동맥혈의 펄싱의 손가락에 의한 O2소모 때문에 감소할 수도 있다. 이러한 점에서 측정 결과시의 한계가 있다. 따라서 본 논문은 SpO2를 측정할 때 어떠한 움직에 의해 나타나는 motion artifact를 최소화하는 알고리즘을 고찰하였다.

  • PDF

Effectiveness of a Turbo Direction Change for Reduction of Motion Artifact in Magnetic Resonance Enterography

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.421-424
    • /
    • 2016
  • The purpose of this study is to evaluate an effectiveness of switching turbo direction to improve motion artifacts of small bowels and aorta. From June to October 2015, 60 patients suspected of having Crohn's disease were enrolled. The MR Enterography scans were performed using same protocol other than the turbo direction: with the Z phase encoding (group A) and with Y phase encoding (group B). Qualitative analysis of each group was performed to evaluate the effectiveness of switching turbo direction from Z to Y. As a result, the 5-point Likert scale for paired observers were $2.33{\pm}0.88$ for group A and $3.80{\pm}0.85$ for group B on dynamic contrast enhanced coronal images. In conclusion, group B is proved to be superior to group A and can lessen the motion artifacts derived from phase shifts.

지수가중 이동평균 기반의 PPG 신호 동잡음 제거 (The Motion Artifact Reduction from the PPG based on EWMA)

  • 이준연
    • 디지털융복합연구
    • /
    • 제11권8호
    • /
    • pp.183-190
    • /
    • 2013
  • PPG 신호는 심장의 박동에 동기된 유사 주기 신호이다. 본 논문에서는 PPG 신호의 유사주기성을 이용한 지수가중 이동평균필터 방법을 제안한다. 이 필터링 방법은 PPG 신호를 주기적으로 분리하여 각 주기 신호의 같은 순번에 있는 샘플들끼리 평균을 취하는 방법이다. 연속된 PPG 신호의 주기중에 동잡음이 혼입되었다면 주기를 기준으로 PPG 신호를 분리한 후, 각 주기의 샘플수를 조정하여 같은 샘플수를 가지게 만든다. 이 주기들을 2차원으로 배열한 후 현재 주기부터 이전 각 주기의 샘플끼리 평균을 취함으로써 훼손없이 동잡음을 제거할 수 있었다.

주기적 이동평균필터를 이용한 동잡음 제거 (The Motion Artifact Reduction using Periodic Moving Average Filter)

  • 이준연
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권4호
    • /
    • pp.75-82
    • /
    • 2012
  • PPG 신호는 심장의 박동에 동기된 유사 주기 신호이다. 본 논문에서는 PPG 신호의 유사주기성을 이용한 주기적 이동평균필터 방법을 제안한다. 이 필터링 방법은 PPG 신호를 주기적으로 분리하여 각 주기 신호의 같은 순번에 있는 샘플들끼리 평균을 취하는 방법이다. 연속된 PPG 신호의 주기 중에 동잡음이 혼입되었다면 주기를 기준으로 PPG 신호를 분리한 후, 각 주기의 샘플수를 조정하여 같은 샘플수를 가지게 만든다. 이 주기들을 2차원으로 배열한 후 현재 주기부터 이전 각 주기의 샘플끼리 평균을 취함으로써 훼손 없이 동잡음을 제거할 수 있었다.

동잡음 저감을 위한 심전도 전극 특성에 대한 연구 (Study on Characteristics of ECG Electrodes for Motion Artifact Reduction)

  • 강영환;박재순;조범기;최상동;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.