• Title/Summary/Keyword: monitoring results

Search Result 8,859, Processing Time 0.034 seconds

A social network monitoring procedure based on community statistics (커뮤니티 통계량에 기반한 사회 연결망 모니터링 절차)

  • Joo Weon Lee;Jaeheon Lee
    • The Korean Journal of Applied Statistics
    • /
    • v.36 no.5
    • /
    • pp.399-413
    • /
    • 2023
  • Recently, monitoring and detecting anomalies in social networks have become an interesting research topic. In this study, we investigate the detection of abnormal changes in a network modeled by the DCSBM (degree corrected stochastic block model), which reflects the propensity of both individuals and communities. To this end, we propose three methods for anomaly detection in the DCSBM networks: One method for monitoring the entire network, and two methods for dividing and monitoring the network in consideration of communities. To compare these anomaly detection methods, we design and perform simulations. The simulation results show that the method for monitoring networks divided by communities has good performance.

Anti-reflection Coating using Optical Monitoring System (광학적 모니터링 장비를 이용한 안경렌즈의 무반사 코팅)

  • Jung, Boo-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.159-165
    • /
    • 2011
  • Purpose: In this paper, the reliability and reproductivity of anti-reflection (AR) coating on ophthalmic lens using optical monitoring system (OMS) were investigated. Methods: The random error simulation and RunSheet performance in Essential Macleod software to confirm possibility of AR coating using OMS were performed. The coating process of 19 batches was carried out in order to perform reproductivity test of AR coating after simulation process. Results: As a result, the coating results of 19 batches had shown the excellent reproductivity of about 0.5% error. Conclusions: We confirmed the excellent reproductivity and reliability of AR coating on ophthalmic lens using optical monitoring system from our results.

Three-dimensional structural health monitoring based on multiscale cross-sample entropy

  • Lin, Tzu Kang;Tseng, Tzu Chi;Lainez, Ana G.
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.673-687
    • /
    • 2017
  • A three-dimensional; structural health monitoring; vertical; planar; cross-sample entropy; multiscaleA three-dimensional structural health monitoring (SHM) system based on multiscale entropy (MSE) and multiscale cross-sample entropy (MSCE) is proposed in this paper. The damage condition of a structure is rapidly screened through MSE analysis by measuring the ambient vibration signal on the roof of the structure. Subsequently, the vertical damage location is evaluated by analyzing individual signals on different floors through vertical MSCE analysis. The results are quantified using the vertical damage index (DI). Planar MSCE analysis is applied to detect the damage orientation of damaged floors by analyzing the biaxial signals in four directions on each damaged floor. The results are physically quantified using the planar DI. With progressive vertical and planar analysis methods, the damaged floors and damage locations can be accurately and efficiently diagnosed. To demonstrate the performance of the proposed system, performance evaluation was conducted on a three-dimensional seven-story steel structure. According to the results, the damage condition and elevation were reliably detected. Moreover, the damage location was efficiently quantified by the DI. Average accuracy rates of 93% (vertical) and 91% (planar) were achieved through the proposed DI method. A reference measurement of the current stage can initially launch the SHM system; therefore, structural damage can be reliably detected after major earthquakes.

Educational Program Evaluation System in a Medical School (일개 의과대학 교육프로그램 평가체제에 대한 연구)

  • Yune, So-Jung;Lee, Sang-Yeoup;Im, Sunju
    • Korean Medical Education Review
    • /
    • v.22 no.2
    • /
    • pp.131-142
    • /
    • 2020
  • A systematic educational program evaluation system for continuous quality improvement in undergraduate medical education is essential. Monitoring and evaluation (M&E) are two distinct but complementary processes referred to in an evaluation system that emphasizes formative purpose. Monitoring involves regular data collection for tracking process and results, while evaluation requires periodic judgment for improvement. We have recently completed implementing an educational evaluation using the M&E concept in a medical school. The evaluation system consists of two loops, one at the lesson/course level and the other at the phase/graduation level. We conducted evaluation activities in four stages: planning, monitoring, evaluation, and improvement. In the planning phase, we clarified the purpose of evaluation, formulated a plan to engage stakeholders, determined evaluation criteria and indicators, and developed an evaluation plan. Next, during the monitoring phase, we developed evaluation instruments and methods and then collected data. In the evaluation phase, we analyzed results and evaluated the criteria of the two loops. Finally, we reviewed the evaluation results with stakeholders to make improvements. We have recognized several problems including excessive burden, lack of expertise, insufficient consideration of stakeholders' evaluation questions, and inefficient data collection. We need to share the value of evaluation and build a system gradually.

Application of Internet of Things Based Monitoring System for indoor Ganoderma Lucidum Cultivation

  • Quoc Cuong Nguyen;Hoang Tan Huynh;Tuong So Dao;HyukDong Kwon
    • International journal of advanced smart convergence
    • /
    • v.12 no.2
    • /
    • pp.153-158
    • /
    • 2023
  • Most agriculture plantings are based on traditional farming and demand a lot of human work processes. In order to improve the efficiency as well as the productivity of their farms, modern agricultural technology was proven to be better than traditional practices. Internet of Things (IoT) is usually related in modern agriculture which provides the farmer with a real-time monitoring condition of their farm from anywhere and anytime. Therefore, the application of IoT with a sensor to measure and monitors the humidity and the temperature in the mushroom farm that can overcome this problem. This paper proposes an IoT based monitoring system forindoor Ganoderma lucidum cultivation at a minimal cost in terms of hardware resources and practicality. The results show that the data of temperature and humidity are changing depending on the weather and the preliminary experimental results demonstrated that all parameters of the system were optimized and successful to achieve the objective. In addition, the analysis results show that the quality of Ganoderma lucidum produced on the research method conforms to regulations in Vietnam.

Development of Engine/Rotor Vibration Analysis and Monitoring System(EVAMOS) for Marine Vessels (선박용 엔진/회전체 진동 분석 및 모니터링 시스템(EVAMOS) 개발에 관하여)

  • Lee, D.C.;Joo, G.S.;Nam, T.K.;Kim, E.S.;Kim, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.331-336
    • /
    • 2008
  • Engine builders have separately developed and applied torsional, axial and structural vibration monitoring system on most marine engines. These systems displayed their results for engine or ship operation engineers and were not regularly stored at the hardware of computer. So, tile history and trend of various engine and hull vibrations was not supported for preventive maintenance and to protect the failure of these activity or function. The integrated vibration or stress monitoring system(EVAMOS : Engine/Rotor Analysis and monitoring System) in marine diesel engine, its machineries and hull have been developed by the dynamics laboratory of Mokpo Maritime University during last 3 years. This paper introduces tile design conception and ability of commercial software EVAMOS with field data on several actual tests.

  • PDF

Asymptotic properties of monitoring procedure for parameter change in heteroscedastic time series models (이분산 시계열 모형에서 모수의 변화에 대한 모니터링 절차의 점근 성질)

  • Kim, Soo Taek;Oh, Hae June
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.4
    • /
    • pp.467-482
    • /
    • 2020
  • We investigate a monitoring procedure for the early detection of parameter changes in location-scale time series models. We introduce a detector for monitoring procedure based on modified residual cumulative sum (CUSUM). The asymptotic properties of the monitoring procedure are established under the null and alternative hypotheses. Simulation results and data analysis are also provided for illustration.

Moderating Effects of Parental Attachment and Parental Monitoring in the Relationship between Adolescent Stress and Problem Behavior (청소년의 스트레스와 문제행동의 관계에 대한 부모애착 및 부모감독의 중재효과)

  • Ahn, Hye-Won;Lee, Jae-Yeon
    • Korean Journal of Child Studies
    • /
    • v.30 no.1
    • /
    • pp.77-88
    • /
    • 2009
  • This study explored moderating effects of parental attachment andparental monitoring in the relationship between stress and problem behavior among Korean adolescents. The Korean Youth Panel Study (KYPS) was used as sample data with a total of 2,503 11th grade students involved in this study. Results of hierarchical regression analyses showed that parental attachment (for both male and female adolescents) and parental monitoring (for male adolescents) played the role of moderators in the relationship between stress and problem behavior. That is, good parental attachment and monitoring reduced stress inducing problem behavior for male adolescents but only parental attachment reduced stress inducing problem behavior for female adolescents. Conclusions highlighted the importance of parents' role in the prevention of adolescent problem behavior.

  • PDF

A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems (동기 발전기 시스템의 실시간 모니터링 기술 개발)

  • Cho, Hyun Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

A Study on the Development of Optical-Fiber Water Leakage Sensing System (광파이버 누수센싱 시스템 개발에 관한 연구)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.