• 제목/요약/키워드: monitoring interval

검색결과 366건 처리시간 0.024초

Interim Results of Simultaneous Time Monitoring of SiO and $H_2O$ Masers Toward Water Fountain Sources

  • Kim, Jaeheon;Cho, Se-Hyung;Yoon, Dong-Hwan;Yun, Youngjoo;Byun, Do-Young
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.77.2-77.2
    • /
    • 2013
  • We present the interim results of simultaneous time monitoring observations of $^{28}SiO$ v = 1, 2, J = 1-0, $^{29}SiO$ v = 0, J = 1-0 and $H_2O$ $6_{16}-5_{23}$ maser lines toward 10 known water fountain sources at a post-AGB stage. The observations have been carried out from 2009 June to 2013 September using the 21m single dish radio telescopes of the Korean VLBI Network. From six sources, we detected well separated red- and blue-shifted $H_2O$ maser features with large velocity ranges more than 100 km $s^{-1}$. From four sources, we detected red- and/or blue-shifted $H_2O$ maser features depended on observational epochs. However, we could not detected SiO maser emission from any sources and any epochs. For a representative water fountain source W43A, we obtained $H_2O$ maser spectra at 17 epochs which show a clear bipolar and discontinuous mass ejections. They also showed a periodic change between red-shifted and blue-shifted peaks. However, we need a more regular and short-time interval monitoring observations in order to fix the period and peak intensity variation interval.

  • PDF

Properties of variable sampling interval control charts

  • Chang, Duk-Joon;Heo, Sun-Yeong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권4호
    • /
    • pp.819-829
    • /
    • 2010
  • Properties of multivariate variable sampling interval (VSI) Shewhart and CUSUM charts for monitoring mean vector of related quality variables are investigated. To evaluate average time to signal (ATS) and average number of switches (ANSW) of the proposed charts, Markov chain approaches and simulations are applied. Performances of the proposed charts are also investigated both when the process is in-control and when it is out-of-control.

변량표본추출간격을 이용한 범위관리도와 분산관리도의 ATS비교 (A Comparison of Average Time Rate with range and variance chart when using variable sampling interval)

  • 이희춘;지선수
    • 산업경영시스템학회지
    • /
    • 제17권30호
    • /
    • pp.101-106
    • /
    • 1994
  • The basic of the VSI charts is that if the sample statistic computed after a sample is taken shows some indication of a process change than the sampling interval before the next sample should be short otherwise long. This paper was shown the VSS chart can be considerably more efficient than the FSS chart and the effectiveness of VSI R chart with S chart used for monitoring a process standard deviation.

  • PDF

A wireless monitoring system for monocrystalline PV system

  • Kelebekler, Ersoy;Ergun, Riza Emre
    • Advances in Energy Research
    • /
    • 제7권2호
    • /
    • pp.123-134
    • /
    • 2020
  • Photovoltaic systems are progressively attached importance and their installed capacity increases day by day because of their reliability, decremented installation and operating cost and simple construction structure. Generated power obtained from a photovoltaic system changes depending upon regional distinctness, and It can be estimated approximately by taking into consideration mean global radiation amount, temperature and humidity. However, there may be different regional negative or positive factors like dust, air pollution, desert powder which affect generated power. The best reliable data for a region can be obtained from the existing photovoltaic system in the region. For this purpose, a monitoring system for 1000W monocrystalline photovoltaic system constructed at Kocaeli University Uzunciftlik Nuh Cimento Vocational High Scholl is prepared. The installed monitoring system shows and records real values generated from the photovoltaic system and environmental data. In the study, Instantaneous data obtained from the monitoring system for October 2018 and 7th October 2018 is given within figures. Additionally, daily and monthly total energy productions of the photovoltaic system are given for October 2018 and date interval between July 2018 and March 2018, respectively.

ECG신호의 QRS 폭과 RR Interval의 패턴을 이용한 효율적인 VEB 비트 검출 알고리듬 (An Efficient VEB Beats Detection Algorithm Using the QRS Width and RR Interval Pattern in the ECG Signals)

  • 정용주
    • 융합신호처리학회논문지
    • /
    • 제12권2호
    • /
    • pp.96-101
    • /
    • 2011
  • 최근 들어 실시간 원격 ECG모니터링 시스템에 대한 수요가 늘어가고 있으며 가입자의 증가와 더불어 실시간 모니터링 시스템의 자동화에 대한 필요성이 대두되고 있다. 비정상적인 ECG 비트의 자동검출은 이러한 실시간 원격 ECG모니터링 시스템의 성공적인 상업화를 위해서는 반드시 필요한 요소기술이다. 본 논문에서는 이러한 점에 착안하여 QRS 폭(width)과 RR interval의 패턴을 이용한 효율적인 비정상적 ECG 비트 자동검출알고리듬을 제안하였다. 기존에는 주로 ECG 비트의 상세한 분류에 대해서 많은 연구가 이루어졌으나 이러한 방법들은 분류 오류가 많고 주변 환경이 변화함에 따라서 분류성능의 변동성이 심하다는 단점이 있었다. 또한 정확한 ECG 비트 분류를 위해서는 충분한 양의 훈련데이터를 필요로 하며 특히 분류시에 많은 계산량을 필요로 한다는 문제점도 있었다. 그러나 자동화된 원격 ECG모니터링 시스템을 위해서는 ECG 비트의 세세한 분류 보다는 비트의 정상여부판단이 더 중요하다. 이러한 점에 착안하여 본 논문에서는 ECG 신호의 비정상적인 비트중에서도 가장 빈번이 발생하는 VEBs(Ventricular ectopic beats) 비트의 검출을 시도하였고 제안된 알고리듬을 MIT-BIH 부정맥 데이터베이스에 적용한 결과 만족스러운 VEBs 바트 검출성능을 얻을 수 있었다.

Optimal Monitoring Frequency Estimation Using Confidence Intervals for the Temporal Model of a Zooplankton Species Number Based on Operational Taxonomic Units at the Tongyoung Marine Science Station

  • Cho, Hong-Yeon;Kim, Sung;Lee, Youn-Ho;Jung, Gila;Kim, Choong-Gon;Jeong, Dageum;Lee, Yucheol;Kang, Mee-Hye;Kim, Hana;Choi, Hae-Young;Oh, Jina;Myong, Jung-Goo;Choi, Hee-Jung
    • Ocean and Polar Research
    • /
    • 제39권1호
    • /
    • pp.13-21
    • /
    • 2017
  • Temporal changes in the number of zooplankton species are important information for understanding basic characteristics and species diversity in marine ecosystems. The aim of the present study was to estimate the optimal monitoring frequency (OMF) to guarantee and predict the minimum number of species occurrences for studies concerning marine ecosystems. The OMF is estimated using the temporal number of zooplankton species through bi-weekly monitoring of zooplankton species data according to operational taxonomic units in the Tongyoung coastal sea. The optimal model comprises two terms, a constant (optimal mean) and a cosine function with a one-year period. The confidence interval (CI) range of the model with monitoring frequency was estimated using a bootstrap method. The CI range was used as a reference to estimate the optimal monitoring frequency. In general, the minimum monitoring frequency (numbers per year) directly depends on the target (acceptable) estimation error. When the acceptable error (range of the CI) increases, the monitoring frequency decreases because the large acceptable error signals a rough estimation. If the acceptable error (unit: number value) of the number of the zooplankton species is set to 3, the minimum monitoring frequency (times per year) is 24. The residual distribution of the model followed a normal distribution. This model can be applied for the estimation of the minimal monitoring frequency that satisfies the target error bounds, as this model provides an estimation of the error of the zooplankton species numbers with monitoring frequencies.

In-service Real-time and Continuous Objective Video Quality Assessment for DTV Broadcasting

  • Han, Chan-Ho
    • 한국멀티미디어학회논문지
    • /
    • 제16권1호
    • /
    • pp.50-55
    • /
    • 2013
  • This article presents a simple and reasonable in-service, real-time, and continuous single-ended objective video quality assessment model for DTV broadcasting using a multiburst signal at the bottom of the transient effect area, similar to Vertical Interval Test Signals. The issue of in-service video-quality monitoring in DTV broadcasting is addressed, and an effective method of quality monitoring is presented. The proposed method is also implemented and tested in a range of situations using a simulated HDTV broadcasting network.

Parametric density concept for long-range pipeline health monitoring

  • Na, Won-Bae;Yoon, Han-Sam
    • Smart Structures and Systems
    • /
    • 제3권3호
    • /
    • pp.357-372
    • /
    • 2007
  • Parametric density concept is proposed for a long-range pipeline health monitoring. This concept is designed to obtain the attenuation of ultrasonic guided waves propagating in underwater pipelines without complicated calculation of attenuation dispersion curves. For the study, three different pipe materials such as aluminum, cast iron, and steel are considered, ten different transporting fluids are assumed, and four different geometric pipe dimensions are adopted. It is shown that the attenuation values based on the parametric density concept reasonably match with the attenuation values obtained from dispersion curves; hence, its efficiency is proved. With this concept, field engineers or inspectors associated with long-range pipeline health monitoring would take the advantage of easier capturing wave attenuation value, which is a critical variable to decide sensor location or sensors interval.

Comparison of two sampling intervals and three sampling intervals VSI charts for monitoring both means and variances

  • Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권4호
    • /
    • pp.997-1006
    • /
    • 2015
  • In industrial quality control, when engineers use VSI control procedure they should consider both required time to signal and switching behaviors together in the case of production process changed. Up to the present, many researchers have studied fixed sampling interval (FSI) chart and variable sampling interval (VSI) chart in the points of average number of samples to signal (ANSS) and average time to signal (ATS). However, ANSS and ATS do not provide any switching information between different sampling intervals of VSI schemes. In this study, performances of two sampling intervals VSI chart and three sampling intervals VSI chart are evaluated and compared. The numerical results show that ANSS and ATS values of two sampling intervals VSI chart and three sampling interval VSI chart are similar regardless the amount of shifts. However, the values of switching behaviors including ANSW are less efficient in three sampling intervals VSI charts than in two sampling intervals VSI chart.

Evaluating Properties of Variable Sampling Interval EWMA Control Charts for Mean Vector

  • Kwon, Yong-Man;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제16권3호
    • /
    • pp.639-650
    • /
    • 2005
  • Theoretical and numerical comparison have shown that variable sampling interval (VSI) charts are substantially more efficient than fixed sampling interval(FSI) charts in term of ATS(average time to signal). But the frequency of switching between different sampling intervals is a complicating factor in VSI procedures. VSI EWMA charts for monitoring mean vector of related qualify characteristics are investigated. To compare the efficiencies of the proposed charts, the performances are evaluated for matched FSI and VSI charts in terms of average time to signal(ATS) and average number of samples to signal(ANSS). For the switching behavior of the proposed VSI charts, average number of switches(ANSW) are also investigated.

  • PDF