• 제목/요약/키워드: monitoring device

검색결과 1,393건 처리시간 0.029초

Invention of the Guide Catheter Irrigation Monitoring Device for Neuroendovascular Therapy

  • Ozkul, Ayca;Park, Jong-Hyun;Shin, Dong-Seung;Yilmaz, Ali;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권4호
    • /
    • pp.471-474
    • /
    • 2017
  • Objective : The thromboembolic events during neuroendovascular therapy (NET) are the major complications of concern that can be occasionally fatal. The thrombotic occlusion of the guide catheter for NET is thought to be the risk of the thromboembolic events. We have developed an idea for inventing the monitoring system of the continuous irrigation through the guide catheter. We herein present a unique invention of the guide catheter irrigation monitoring device. Methods : We have developed ideas for preventing the thrombotic occlusion of the guide catheter. In order to design a convenient device working in the practical use, we have consulted and shared the ideas with the electrical engineers about putting the invention. Results : The guide catheter irrigation monitoring device (GCIMD) consisted of three parts of optical sensor, main body and electric adapter. In brief, the basic principles of working of the GCIMD are as follows. The optical sensor is attached to the dripping chamber of the line to irrigation solution. The main body had the small light and speaker to make an alarm sounds. The sensor monitors the dripping of flush solution. If the dripping stops more than three seconds, a warning alarm has been activated. So, the operating physicians can concentrate and check the guide catheter irrigation. After the use of the GCIMD, there was no major thromboembolic complication in conjunction with the thrombotic occlusion of the guide catheter in our institute. Conclusion : We have developed a brilliant invention of the GCIMD for NET.

Versatile robotic platform for structural health monitoring and surveillance

  • Esser, Brian;Huston, Dryver R.
    • Smart Structures and Systems
    • /
    • 제1권4호
    • /
    • pp.325-338
    • /
    • 2005
  • Utilizing robotic based reconfigurable nodal structural health monitoring systems has many advantages over static or human positioned sensor systems. However, creating a robot capable of traversing a variety of civil infrastructures is a difficult task, as these structures each have unique features and characteristics posing a variety of challenges to the robot design. This paper outlines the design and implementation of a novel robotic platform for deployment on ferromagnetic structures as an enabling structural health monitoring technology. The key feature of this design is the utilization of an attachment device which is an advancement of the common magnetic base found in the machine tool industry. By mechanizing this switchable magnetic circuit and redesigning it for light weight and compactness, it becomes an extremely efficient and robust means of attachment for use in various robotic and structural health monitoring applications. The ability to engage and disengage the magnet as needed, the very low power required to do so, the variety of applicable geometric configurations, and the ability to hold indefinitely once engaged make this device ideally suited for numerous robotic and distributed sensor network applications. Presented here are examples of the mechanized variable force magnets, as well as a prototype robot which has been successfully deployed on a large construction site. Also presented are other applications and future directions of this technology.

Web Information Systems for Safety and Health Monitoring in Subway Stations

  • Choi, Gi-Heung
    • International Journal of Safety
    • /
    • 제8권1호
    • /
    • pp.10-13
    • /
    • 2009
  • In this study, a framework for web-based information system in VDN environment for safety and health monitoring in subway stations is suggested. Since physical variables that describing safety and health need to be closely monitored in multiple locations in subway stations, concept of distributed monitoring network using wireless media needs to be implemented. Connecting remote wireless sensor network and device (LonWorks) networks to the IP network based on the concept of VDN can provide a powerful, integrated and distributed monitoring performance, making a web-based information system possible.

스마트폰 기반에서 안전한 디바이스 모니터링을 위한 디바이스 식별 및 통신 기법 설계 (A Design of Device Identification and Communication Method for Secure Device Monitoring based Smart Phone)

  • 진병욱;안희학;전문석
    • 디지털산업정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.69-78
    • /
    • 2017
  • As the smartphone-based devices are diffused and developed rapidly, they provide the convenience to the users. The abovementioned sentence technologies are being used not only in the existing sensor and wireless network technology but also in the application services of the diverse fields application services such as smart appliance, smart car, smart health care, etc. and the new fusion paradigm from the industry is presented by undertaking the researches in diverse area by the enterprises and research institutions. However, the smart environment exposes its weaknesses in the mobile terminal area, existing wireless network and IT security area. In addition, due to new and variant ways of attack, not only the critical information are disclosed However also the financial damages occur. This paper proposed the protocol to perform the smartphone-based safe device monitoring and safe communication. The proposed protocol designed the management procedure of registration, identification, communication protocol and device update management protocol and the safety against the attack techniques such as the an-in-the-middle-attack, impersonation attack, credential threat, information leaks and privacy invasion was analyzed. It was observed that the proposed protocol showed the performance improved by approximately 52% in the communication process than the existing system.

Real-Time Detection of Residual Free Chlorine and pH in Water Using a Microchannel Device

  • Kim, Sam-Hwan;Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.368-374
    • /
    • 2011
  • A microfluidic device for real-time monitoring of residual free chlorine and pH in water based on optical absorption is proposed. The device consists of a serpentine micromixer for mixing samples with a reagent, and a photodiode and light emitting diode(LED) for the detection of light absorbance at specific wavelengths, determined for specific reagent combinations. Spectral analyses of the samples mixed with N, N'-diethyl-p-phenylenediamine(DPD) reagent for chlorine determination and bromothymol blue(BTB) for pH measurement are performed, and the wavelengths providing the most useful linear changes in absorbance with chlorine concentration and pH are determined and used to select the combination of LED and photodiode wavelengths for each analyte. In tests using standard solutions, the device is shown to give highly reproducible results, demonstrating the feasibility of the device for the inexpensive and continuous monitoring of water quality parameters with very low reagent consumption.

사출성형공정 모니터링용 엣지 디바이스 개발 및 평가 (Development and evaluation of edge devices for injection molding monitoring)

  • 김종선;이준한
    • Design & Manufacturing
    • /
    • 제14권4호
    • /
    • pp.25-39
    • /
    • 2020
  • In this study, an edge device that monitors the injection molding process by measuring the mold vibration(acceleration) signal and the mold surface temperature was developed and evaluated its performance. During injection molding, signals of the injection start, V/P switchover, and packing end sections were obtained through the measurement of the mold vibration and the injection time and packing time were calculated by using the difference between the times of the sections. Then, the mold closed and mold open signals were obtained using a magnetic hall sensor, and cycle time was calculated by using the time difference between the mold closed time each process. As a result of evaluating the performance by comparing the process data monitored by the edge device with the shot data recorded on the injection molding machine, the cycle time, injection time, and packing time showed very small error of 0.70±0.38%, 1.40±1.17%, and 0.69±0.82%, respectively, and the values close to the actual were monitored and the accuracy and reliability of the edge device were confirmed. In addition, it was confirmed that the mold surface temperature measured by the edge device was similar to the actual mold surface temperature.

전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링 (Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module)

  • 정득일;손영대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

u-Healthcare를 위한 바이오 단말기의 개발 현황 (Current Developments of Biomedical Mobile Devices for Ubiquitous Healthcare)

  • 이태수;홍주현
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권3호
    • /
    • pp.185-190
    • /
    • 2009
  • Biomedical mobile devices for ubiquitous healthcare consist of biomedical sensors and communication terminal. They have two types of configuration. One is the sensor-network type device using wired or wireless communication with intelligent sensors to acquire biomedical data. The other is the sensor embedded type device, where the data can be acquired directly by itself. There are many examples of sensor network type, such as, fall detection sensor, blood glucose sensor, and ECG sensors networked with commercial PDA phone and commercial phone terminal for ubiquitous healthcare. On the other hand, sensor embedded type mounts blood glucose sensor, accelerometer, and etc. on commercial phone. However, to enable true ubiquitous healthcare, motion sensing is essential, because users go around anywhere and their signals should be measured and monitored, when they are affected by the motion. Therefore, in this paper, two biomedical mobile devices with motion monitoring function were addressed. One is sensor-network type with motion monitoring function, which uses Zigbee communication to measure the ECG, PPG and acceleration. The other is sensor-embedded type with motion monitoring function, which also can measure the data and uses the built-in cellular phone network modem for remote connection. These devices are expected to be useful for ubiquitous healthcare in coming aged society in Korea.

A Preliminary Research on Optical In-Situ Monitoring of RF Plasma Induced Ion Current Using Optical Plasma Monitoring System (OPMS)

  • Kim, Hye-Jeong;Lee, Jun-Yong;Chun, Sang-Hyun;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.523-523
    • /
    • 2012
  • As the wafer geometric requirements continuously complicated and minutes in tens of nanometers, the expectation of real-time add-on sensors for in-situ plasma process monitoring is rapidly increasing. Various industry applications, utilizing plasma impedance monitor (PIM) and optical emission spectroscopy (OES), on etch end point detection, etch chemistry investigation, health monitoring, fault detection and classification, and advanced process control are good examples. However, process monitoring in semiconductor manufacturing industry requires non-invasiveness. The hypothesis behind the optical monitoring of plasma induced ion current is for the monitoring of plasma induced charging damage in non-invasive optical way. In plasma dielectric via etching, the bombardment of reactive ions on exposed conductor patterns may induce electrical current. Induced electrical charge can further flow down to device level, and accumulated charges in the consecutive plasma processes during back-end metallization can create plasma induced charging damage to shift the threshold voltage of device. As a preliminary research for the hypothesis, we performed two phases experiment to measure the plasma induced current in etch environmental condition. We fabricated electrical test circuits to convert induced current to flickering frequency of LED output, and the flickering frequency was measured by high speed optical plasma monitoring system (OPMS) in 10 kHz. Current-frequency calibration was done in offline by applying stepwise current increase while LED flickering was measured. Once the performance of the test circuits was evaluated, a metal pad for collecting ion bombardment during plasma etch condition was placed inside etch chamber, and the LED output frequency was measured in real-time. It was successful to acquire high speed optical emission data acquisition in 10 kHz. Offline measurement with the test circuitry was satisfactory, and we are continuously investigating the potential of real-time in-situ plasma induce current measurement via OPMS.

  • PDF

광섬유 센서를 사용한 항공기용 하중 모니터링 시스템 개발과 지상시험 적용 (Aircraft Load Monitoring System Development & Application to Ground Tests Using Optical Fiber Sensors)

  • 박찬익;하재석;김상용
    • 한국항공우주학회지
    • /
    • 제45권8호
    • /
    • pp.639-646
    • /
    • 2017
  • 본 논문에서는 군용 항공기를 위한 새로운 하중 모니터링 시스템에 대하여 소개하였다. 이 시스템은 항공기에 장착되는 센서와 탑재장비 및 지상에서 운용되는 지상분석장비로 구성된다. 이 시스템을 이용하여 항공기에 작용하는 구조정적하중을 비행파라미터로 추정할 수 있을 뿐 아니라, 정적하중, 동적하중 및 예상치 못한 이벤트에 의한 구조물의 응답을 센서로 측정할 수 있다. 특히 다점 측정이 가능한 광섬유 센서를 사용하였다. 탑재장비는 관련 군사규격서의 요구도를 만족하도록 설계되었으며, 일련의 환경시험으로 입증하였다. 본 시스템은 비행시험에 앞서 지상구조시험에 사용되고 평가되었으며, 향후 비행시험평가를 통하여 군용 항공기의 구조하중 모니터링 시스템으로 사용될 예정이다.