• Title/Summary/Keyword: monitoring and verification

Search Result 458, Processing Time 0.023 seconds

A low cost miniature PZT amplifier for wireless active structural health monitoring

  • Olmi, Claudio;Song, Gangbing;Shieh, Leang-San;Mo, Yi-Lung
    • Smart Structures and Systems
    • /
    • v.7 no.5
    • /
    • pp.365-378
    • /
    • 2011
  • Piezo-based active structural health monitoring (SHM) requires amplifiers specifically designed for capacitive loads. Moreover, with the increase in number of applications of wireless SHM systems, energy efficiency and cost reduction for this type of amplifiers is becoming a requirement. General lab grade amplifiers are big and costly, and not built for outdoor environments. Although some piezoceramic power amplifiers are available in the market, none of them are specifically targeting the wireless constraints and low power requirements. In this paper, a piezoceramic transducer amplifier for wireless active SHM systems has been designed. Power requirements are met by two digital On/Off switches that set the amplifier in a standby state when not in use. It provides a stable ${\pm}180$ Volts output with a bandwidth of 7k Hz using a single 12 V battery. Additionally, both voltage and current outputs are provided for feedback control, impedance check, or actuator damage verification. Vibration control tests of an aluminum beam were conducted in the University of Houston lab, while wireless active SHM tests of a wind turbine blade were performed in the Harbin Institute of Technology wind tunnel. The results showed that the developed amplifier provided equivalent results to commercial solutions in suppressing structural vibrations, and that it allows researchers to perform active wireless SHM on moving objects with no power wires from the grid.

Actinometric Investigation of In-Situ Optical Emission Spectroscopy Data in SiO2 Plasma Etch

  • Kim, Boom-Soo;Hong, Sang-Jeen
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.3
    • /
    • pp.139-143
    • /
    • 2012
  • Optical emission spectroscopy (OES) is often used for real-time analysis of the plasma processes. OES has been suggested as a primary plasma process monitoring tool. It has the advantage of non-invasive in-situ monitoring capability but selecting the proper wavelengths for the analysis of OES data generally relies on empirically established methods. In this paper, we propose a practical method for the selection of OES wavelength peaks for the analysis of plasma etch process and this is done by investigating reactants and by-product gas species that reside in the plasma etch chamber. Wavelength selection criteria are based on the standard deviation and correlation coefficients. Moreover, chemical actinometry is employed for the normalization of the selected wavelengths. We also present the importance of chemical actinometry of OES data for quantitative analysis of plasma. Then, the suggested OES peak selection method is employed.. This method is used to find out the reason behind abnormal etching of PR erosion during a series of $SiO_2$ etch processes using the same recipe. From the experimental verification, we convinced that OES is not only capable for real-time detection of abnormal plasma process but it is also useful for the analysis of suspicious plasma behavior.

On-line UHF partial discharge monitoring system for Gas- insulated switchgears (GIS) (가스절연개폐장치 고장예방을 위한 UHF 부분방전 상시 감시 시스템)

  • Choi, Jae-Ok;Kim, Young-Ro;Hwang, Chul-Min;Lee, Young-Sang;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2066-2068
    • /
    • 2005
  • We developed an on-line Ultra-high frequency partial discharge monitoring system to prevent a catastrophic failure of gas- insulated switchgears. The system has been tested in the laboratory for detection of various UHF PD signals. We also performed detection sensitivity verification tests and compared them with conventional IEC60270 method.

  • PDF

Simulation to Evaluate CCTV Positioning in Use of Ray-Tracing Algorithm (Ray-Tracing 알고리즘을 이용한 CCTV배치 평가시뮬레이션)

  • Kim, Suk-Tae;Ahn, Sang-Ook
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.6
    • /
    • pp.40-48
    • /
    • 2013
  • Utilization of CCTV in crime prevention for public safety is accepted as the most effective measure in terms of crime prevention and control. Also, it is frequently used as a device that shows evidence of an unexpected situation or record on public social relationship. However, it is rare to find a study that qualitatively accessed the monitoring performance of a certain space depending on the choice and positioning of CCTVs. Thus, this study suggested a technology that can quantitatively compare and assess the monitoring performance of CCTVs depending on view angle and effective sight range of cameras as well as the monitoring performance depending on positioning measures. For the analysis, the concept of 3-dimensional surveillance field in the form of a frustum was suggested while deriving 3-dimensional range of sight and quantitative monitoring performance by applying Isovist theory. For the analysis technology, space of analysis subject, point of view (camera), and target point (measurement node) were installed at a 3-dimensional space and in use of ray-tracing algorithm, the line segment that was visually connected between the point of view and target point was extracted and accumulated. For such verification, analysis application was constructed and then applied to four alternative models on view angle and distance as well as four alternatives on positioning in order to verify its efficacy. Through the experiment, it was possible to compare and assess visibility depending on alternatives while quantifying the results by understanding the shadow areas beyond the monitoring range.

On-line Generation of Three-Dimensional Core Power Distribution Using Incore Detector Signals to Monitor Safety Limits

  • Jang, Jin-Wook;Lee, Ki-Bog;Na, Man-Gyun;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.528-539
    • /
    • 2004
  • It is essential in commercial reactors that the safety limits imposed on the fuel pellets and fuel clad barriers, such as the linear power density (LPD) and the departure from nucleate boiling ratio (DNBR), are not violated during reactor operations. In order to accurately monitor the safety limits of current reactor states, a detailed three-dimensional (3D) core power distribution should be estimated from the in-core detector signals. In this paper, we propose a calculation methodology for detailed 3D core power distribution, using in-core detector signals and core monitoring constants such as the 3D Coupling Coefficients (3DCC), node power fraction, and pin-to-node factors. Also, the calculation method for several core safety parameters is introduced. The core monitoring constants for the real core state are promptly provided by the core design code and on-line MASTER (Multi-purpose Analyzer for Static and Transient Effects of Reactors), coupled with the core monitoring program. through the plant computer, core state variables, which include reactor thermal power, control rod bank position, boron concentration, inlet moderator temperature, and flow rate, are supplied as input data for MASTER. MASTER performs the core calculation based on the neutron balance equation and generates several core monitoring constants corresponding to the real core state in addition to the expected core power distribution. The accuracy of the developed method is verified through a comparison with the current CECOR method. Because in all the verification calculation cases the proposed method shows a more conservative value than the best estimated value and a less conservative one than the current CECOR and COLSS methods, it is also confirmed that this method secures a greater operating margin through the simulation of the YGN-3 Cycle-1 core from the viewpoint of the power peaking factor for the LPD and the pseudo hot pin axial power distribution for the DNBR calculation.

Design and Verification using Energy Consumption Model of Low Power Sensor Network for Monitoring System for Elderly Living Alone (독거노인 모니터링 시스템을 위한 저전력 센서 네트워크 설계 및 에너지 소모 모델을 이용 검증)

  • Kim, Yong-Joong;Jung, Kyung-Kwon
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.39-46
    • /
    • 2009
  • Wireless sensor networks consist of small, autonomous devices with wireless networking capabilities. In order to further increase the applicability in real world applications, minimizing energy consumption is one of the most critical issues. Therefore, accurate energy model is required for the evaluation of wireless sensor networks. In this paper we analyze the power consumption for wireless sensor networks. To develop the power consumption model, we have measured the power characteristics of commercial Kmote node based on TelosB platforms running TinyOS. Based on our model, the estimated lifetime of a battery powered sensor node can use about 6.9 months for application of human detection using PIR sensors. This result indicates that sensor nodes can be used in a monitoring system for elderly living alone.

  • PDF

Development of Ground Monitoring and Control System for Korea Augmentation Satellite System

  • Daehee Won;Chulhee Choi;Eunsung Lee;Hantae Cho;Dongik Jang;Eunok Jang;Heetaek Lim;Ho Sung Lee;Jungja Kim;Joohap Choi
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 2023
  • The Korea Augmentation Satellite System (KASS) is the first satellite navigation enhancement system in Korea developed in compliance with international standards. Technologies accumulated during the development process should be spread to industries such as academia and serve as the basis for developing the domestic satellite navigation field. This paper introduces the development process from design to implementation, testing, and verification of KASS control systems (KCS). First, development standards, milestones, requirements, and interface standards are presented as KCS development methods, and major functional design, physical design, and hardware/software implementation are described based on the allocated requirements. Subsequently, the verification environment, procedures, and results of the development product are covered and the developed operational and maintenance procedures are described. In addition, based on the experience gained through the development, suggestions were made for beneficial technology development and organization when promoting satellite navigation projects in the future. Since this work has important historical value for the development of domestic satellite navigation, it is expected that the development results will be shared with academia and industry in the future and be used as basic data for similar development.

Remote Communication of sensor data in Ballast Water Treatment System (선박 평형수 처리 시스템에서 센서 데이터의 원격 통신)

  • Kim, Chin-Hoon;Kim, Joo-Man;Kim, Byoung-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.139-147
    • /
    • 2014
  • The ballast water may be discharged into another sea area with marine organisms, it caused problems to disturb the marine ecosystem. So, in order to remove these environmental risk factors, the IMO has mandated the installation of BWTS to the all ships. Our monitoring system diagnose and predict a failure of BWTS by analyzing the sensor information of BWTS collected from which the ships scattered in the ocean of several. This paper presents the design and implementation of communication modules for BWTS remote monitoring considering the satellite communication charge fee. In the our study, we implemented the safety and cost-saving communication modules by LabVIEW program. The collected sensor informations is encrypted and compressed by LabVIEW modules running on RIO. Then they will be transfer to the land server and will be decrypt to enable monitoring in the land server. For the verification, we build the test modules which can verify from collecting the sensor data to consuming them in the monitoring server. We carried out 20 times for the data pattern in all of case. So, we verified the excellent functionality and reliability through the experimental result.

Active Lamb Wave Propagation-based Structural Health Monitoring for Steel Plate (능동 램파 전파에 기초한 강판의 구조건전성 모니터링)

  • Jeong, Woon;Seo, Ju-Won;Kim, Hyeung-Yun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.421-431
    • /
    • 2009
  • This paper is the study on the verification of structural health monitoring (SHM) algorithm based on the ultrasonic guided wave. An active inspection system using Lamb wave (LW) for SHM was considered. The basic study about the application of this algorithm was performed for detecting the circular notch defect in steel plate. LW testing technique, pitch-catch method, was used for interpretation of circular notch defect with depth of 50% of plate thickness and 7 mm width. Damage characterization takes place by comparing $S_0$ mode sensor signals collected before and after the damage event. By subtracting the signals of both conditions from each other, a scatter signal is produced which can be used for damage localization. The continuous Gabor wavelet transform is used to attain the time between the arrivals of the scatter and sensor signals. A new practical damage monitoring algorithm, based on damage monitoring polygon and pitch-catch method, has been proposed and verified with good accuracy. The possible damage location can be estimated by the average on calculated location points and the damage extent by the standard deviation.

A Study on the Application Method of Mechanochromic Sensor for Crack Monitoring in Buildings (건축물 균열 모니터링을 위한 역학변색센서 활용 기법에 관한 연구)

  • Choe, Gyeong-Chol;Kim, Hong-Seop;Jeon, Jun-Seo;Lee, Mun-Hwan;Pyeon, Su-Jeong;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.69-79
    • /
    • 2023
  • In this study, an experimental study was conducted on the development of crack monitoring technology in buildings using a mechanochromic sensor. After attaching a mechanochromic sensor to the cracks induced in the concrete specimen, the color variation image of the sensor according to the progress of the cracks was taken. In addition, a method of analyzing a sensor color variation image was proposed, and an equation for deriving a crack's width from the relationship between the analysis result and the crack width was also proposed. In addition, the possibility of using an mechanochromic sensor for monitoring cracks in buildings was confirmed through the verification of crack width monitoring technology.