• Title/Summary/Keyword: modified electrodes

Search Result 247, Processing Time 0.026 seconds

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Studies on the Anodic Oxidation Behavior of Methanol and L-Ascorbic Acid by Using Glassy Carbon Electrodes Modified with Inorganic-Metal Polymeric Films (무기 금속 고분자 막을 도포시킨 유리질 탄소전극을 이용한 메탄올과 L-ascorbic acid의 양극 산화 거동에 관한 연구)

  • Yoo, Kwang-Sik;Woo, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.347-352
    • /
    • 1998
  • A study was carried out on the elelctrochemical characteristics of chemically modified electrodes (CMEs) by cyclic voltammetry. Fabrication of CMEs was made by coating with mixed valence (mv) inorganic-metal polymeric films on the glassy carbon electrode surface by potential cycling. Anodic oxidation behavior of methanol and L-ascorbic acid was studied by using CMEs working electrode. Deposition of films such as mv ruthenium oxo/ruthenium cyanide film (mv Ru-O/CN-Ru), mv ruthenium oxo/ferrocyanide film (mv Ru-O/$Fe(CN)_6$), and mv ruthenium oxo/ruthenium cyanide/Rhodium film (mv Ru-O/CN-Ru/Rh) was obtained to coat by scan rate of 50 mV/sec within the specified potential range (-0.5V ~ +1.2V). Film thickness was controlled by the repeat of the potential cycling. Anodic oxidation behavior of methanol was as follow. Calibration graph by using mv Ru-O/CN-Ru film showed linearly from 10 mM to 80 mM MeOH with slope factor of $-7.552{\mu}A/cm^2$. Although slope factor by using mv Ru-O/$Fe(CN)_6$ film was $-5.13{\mu}A/cm^2$, yet linear range of calibration graph could be extended from 10 mM to 100 mM MeOH. Anodic oxidation behavior of L-ascorbic acid was studied by mv Ru-O/CN-Ru film on the glassy carbon electrode and the glassy carbon electrode with Rh film, Glassy carbon electrode modified with Ru polymeric film was showed better sensitivity than the Rh-glassy carbon modified electrode (mv Ru-O/CN-Ru/Rh). Calibration graph was linear from 0.1 mM to 5 mM L-ascorbic acid by using glassy carbon electrode modified with Ru polymeric film. Solpe factor and relative coefficient are $-84.78{\mu}A/mM$ and 0.998, respectively.

  • PDF

Characteristics of ${\alpha}$-Cyclodextrin Modified Carbon Paste Electrode (${\alpha}$-Cyclodextrin으로 화학수식된 Carbon Paste 전극의 특성)

  • Jeon, Young-Guk;Kim, Bong-Weon;Kim, Hee-Jung;Cho, Young-Dal;Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.235-243
    • /
    • 1996
  • A carbon paste electrode were chemically modified using ${\alpha}$-cyclodextrin. Characteristics of chemically modified carbon paste electrodes were studied on the basis of the inclusion complex formation of ${\alpha}$-cyclodextrin and p-nitrophenol in solution. Cyclic voltammetry and differential pulse voltammetry were used to monitor the efficiency of the chemical modification. When the ${\alpha}$-cyclodextrin and carbon powder ratio of 2 : 1 in weight were used, the reduction peak current of p-nitrophenol was decreased almost completely, whereas those of o-nitrophenol and hydroquinone were not changed much. This result is due to the large difference in the inclusion complex formation constants of p-nitrophenol and the other probes with ${\alpha}$-cyclodextrin. Taking advantage of this difference, we can determine the concentration of o-nitrophenol even in the presence of p-nitrophenol.

  • PDF

Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol

  • Park, Chan-Ju;Park, Eun-Heui;Chung, Keun-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.177-180
    • /
    • 2003
  • A glassy carbon electrode(GCE) modified with nafion-DTPA-glycerol was used for the highly selective and sensitive determination of a trace amount of Cu$\^$2+/. Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu$\^$2+/, were optimized. The copper(II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry, A linear range was obtained in the concentration range 1.0${\times}$10$\^$-8/M∼1.0${\times}$10$\^$-6/M Cu(II) with 7 min preconcentration. Further, when an approximate amount of lead(II) is added to the test solution, nafion-DTPA-glycerol modified glassy carbon electrode has a dynamic range of 2 orders magnitude(1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M). The detection limit(3 $\sigma$) was as low as 5.0${\times}$10$\^$-6/M(0.032ppb). The interferences from other metal ions could be reduced by adding KCN into the sample solutions. This method was applied to the determination of coppe,(II) in certified reference material(3.23${\times}$10$\^$-7/M, 21ppb), sea water(9.50${\times}$10/sup-7/M, 60ppb). The result agrees satisfactorily with the value measured by Korea Research Institute of Standard and Science.

  • PDF

Electrochemical Determination of Epinephrine Using Doubly Modified Electrodes with Ni(II)-Macrocyclic Complex and Polyuretane (니켈(II)-거대고리 착물과 폴리 우레탄으로 변성한 이중 전극에서 에피네피린의 전기화학적 정량)

  • Xu, Guang-Ri;Cho, Hyung-Hwa;Kweon, Soo-Geong;Lee, Sang-Hag;Bae, Zun-Ung
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.190-195
    • /
    • 2007
  • A new electrochemical sensor to selectively determine epinephrine was developed and its analytical characteristics has been investigated. A glassy carbon electrode was modified with Ni(II)-macrocyclic complex which has electrocatalytic effect. It was further modified with physiologically suitable and negatively charged polyuretane benzyl L-glutamate(PUBLG). The present electrode showed long term stability and it could be applied to the selective determination of epinephrine in urine sample with various coexisting compounds. Under the optimum experimental conditions the linear range was $8.0\;{\times}\;10^{-7}\;-\;2.0\;{\times}\;10^{-4}\;M$ and the limit of detection was $1.0\;{\times}\;10^{-7}\;M$. The recovery of epinephrine in urine sample diluted 5 times with buffer solution was $101.5({\pm}3.2)%$ for 6 measurements.

Redox Properties of Modified Poly-N,N'-bis(2-pyrrol-1-yl-propyl)-4,4'-Bipyridine Film Electrode (수식된 N,N'-bis(2-pyrrol-1-yl-propyl)-4,4'-bipyridine 고분자 피막전극의 산화-환원 특성)

  • Cha, Seong Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.5
    • /
    • pp.429-435
    • /
    • 2001
  • The monomer N,N'-bis(2-pyrrol-1-yl-propyl)-4,4'-bipyridine(bpb) was electrochemically polymerized on the glassy carbon electrode surface, which was modified with 1:1 ratio of erichrome black T(EBT) and glutathione(GSSG) to give a type of GC/poly-bpb, EBT, GSSG electrode for depositing Zn(II). The diffusion coefficients of the incorporated ions were 2.43${\times}10^{-15}$ and 9.14${\times}10^{-15} cm^2s^{-1}$ before taking Zn(II) ions and after them respectively. The modified electrodes are stable at the electrode process. The polymerized poly-bpb of 2.83${\times}10^4gmol^{-1}$ can deposit 2.15${\times}10^4gmol^{-1}$ of Zn(II). The number of pumping ions involving in the redox procedure at 0.77 V was 81.7% of the captured 180 ions into the polymer matrix, which was 3 times larger than that of the electrode modified with EBT alone.

  • PDF

Antispastic Effects of Electroacupuncture, TENS and NMEs in Stroke Patient (중풍경직에 전침, TENS 및 신경근 자극기의 효과에 대한 연구)

  • Kim, Yong-suk
    • Journal of Acupuncture Research
    • /
    • v.17 no.2
    • /
    • pp.209-220
    • /
    • 2000
  • Spasticity, an abnormal increase in resting muscle tone, is one of the most common symptoms of stroke, and its management is becoming a major issue in rehabilitation. The aims of this study are to determine the effects of electroacupuncture(EA), TENS and neuromuscular electric stimulation(NMES) on spasticity, as well as the possibility of tissue comliance method as a spasticity scale. 45 stroke patients participated in a study of the effects on hemiplegic spasticity of EA, TENS and NMES. Spasticity was measured by modified Ashworth scale on the upper extremity and tissue compliance measurement, penetration mm/kg, on Susamni(LI10) area at just before and after stimulation, and 30 minutes, 1 hour, 2 hours and 24 hours after stimulation. The acupuncture points were applied to Kokchi(LI11), Susamni(LI10), Hapkok(LI4) and Oegwan(TE5) of the affected limb. The electrodes were placed unilaterally on LI11 to LI10 and TE5 to LI4. EA with biphasic wave, 60Hz, 0.4 msec pulse duration and low intensity was applied continuously for 20 minutes. TENS with high frequency, low intensity was applied. NMES was applied with spasticity program for 20 minutes. Each electric stimulation was done on extensor muscles group of forearm for 20 minutes. EA and NMES groups were found to produce a statistically significant decrease(p〈0.05) of spasticity and these effects lasted up to 30 minutes after stimulation. There was no definite correlation between the modified Ashworth scale and tissue compliance measurement. But tissure compliance method was found to be possible as a quantitative measurement on spasticity. There was no significant correlation between the effects of EA and NMES and the characteristics of patient, but significant correlation between the effects of EA and NMES and the modified Ashworth scale.

  • PDF

Effect of Address Discharge Characteristics by Selective Reset Method in AC Plasma Display Panel (교류형 플라즈마 디스플레이에서 선택적 초기화 방법에 의한 기입 방전 특성의 영향)

  • Cho, Byung-Gwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.1004-1008
    • /
    • 2012
  • The effect of address discharge characteristics by selective reset method is investigated to prevent the weakness of address discharge in the middle of a TV-field without increase of the black luminance. To reduce black luminance in AC PDP usually, the first subfield during one TV frame adopted the conventional rising ramp-reset waveform, whereas the other subfields adopted the subsidiary reset waveform without rising ramp type. As the wall charge for the address discharge was accumulated by only the rising ramp waveform during the first reset period, the wall charge on three electrodes was disappeared as time passed and the address discharge would be weakened in the rear subfields. To prevent a reduction of the address discharge characteristics without decrease the black luminance, the modified rising ramp reset waveform was adopted only in the sixth subfield. As a result, a modified driving method could improve the address discharge characteristics compared with selective reset driving scheme with almost the same black luminance.

Reaction between Gas-phase Hydrogen Atom and Chemisorbed Bromine Atoms on a Silicon(001)-(2X1) Surface

  • Park, Jong-Keun;Ree, Jong-Baik;Lee, Sang-Kwon;Kim, Yoo-Hang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2271-2278
    • /
    • 2007
  • Electron transfer of a redox protein at a bare gold electrode is too slow to observe the redox peaks. A novel Nafion-riboflavin functional membrane was constructed during this study and electron transfer of cytochrome c, superoxide dismutase, and hemoglobin were carried out on the functional membrane-modified gold electrode with good stability and repeatability. The immobilized protein-modified electrodes showed quasireversible electrochemical redox behaviors with formal potentials of 0.150, 0.175, and 0.202 V versus Ag/AgCl for the cytochrome c, superoxide dismutase and hemoglobin, respectively. Whole experiment was carried out in the 50 mM MOPS buffer solution with pH 6.0 at 25 oC. For the immobilized protein, the cathodic transfer coefficients were 0.67, 0.68 and 0.67 and electron transfer-rate constants were evaluated to be 2.25, 2.23 and 2.5 s?1, respectively. Hydrogen peroxide concentration was measured by the peroxidase activity of hemoglobin and our experiment revealed that the enzyme was fully functional while immobilized on the Nafion-riboflavin membrane.

Development of $YSZ/La_0.85S_r0.15MnO_3$ Composite Electrodes for Solid Oxide Fuel Cells (고체산화물 연료전지용 $YSZ/La_0.85S_r0.15MnO_3$계 복합전극의 개발)

  • 윤성필;현상훈;김승구;남석우;홍성안
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.9
    • /
    • pp.982-990
    • /
    • 1999
  • YSZ/LSM composite cathode was fabricated by dip-coating of YSZ sol on the internal pore surface of a LSM cathode followed by sintering at low temperature (800-100$0^{\circ}C$) The YSZ coating significantly increased the TPB(Triple Phase Boundary) where the gas the electrode and the electrolyte were in contact with each other. Sinter the formation of resistive materials such as La2Zr2O7 or SrZrO3 was prevented due to the low processing temperature and TPB was increased due to the YSZ film coating the electrode resistance (Rel) was reduced about 100 times compared to non-modified cathode. From the analysis of a.c impedance it was shown that microstructural change of the cathode caused by YSZ film coating affected the oxygen reduction reaction. In the case of non-modified cathode the RDS (rate determining step) was electrode reactions rather than mass transfer or the oxygen gas diffusion in the experimental conditions employed in this study ($600^{\circ}C$-100$0^{\circ}C$ and 0,01-1 atm of Po2) for the YSZ film coated cathode however the RDS involved the oxygen diffusion through micropores of YSZ film at high temperature of 950-100$0^{\circ}C$ and low oxygen partial pressure of 0.01-0.03 atm.

  • PDF