• Title/Summary/Keyword: modified base materials

Search Result 85, Processing Time 0.031 seconds

Pysiological Responses of Diploid and Triploid Far Eastern Catfish, Silurus asotus to Water Temperature Stress

  • Lee, Hyo Bin;Kim, Dong Soo;Gil, Hyun Woo;Park, In-Seok
    • Development and Reproduction
    • /
    • v.22 no.2
    • /
    • pp.165-174
    • /
    • 2018
  • The aim of study is to contribute to this knowledge-base by investigating the respiratory function, the metabolic rate and the difference of physiological responses un-der low water temperature ($20^{\circ}C{\rightarrow}15^{\circ}C$) stress be-tween diploid and triploid far eastern catfish, Silurus asotus. During the 48 hrs of water temperature stress exposure time, the respiratory frequencies, $CO_2$ and ${NH_4}^+$ concentrations of diploid had higher values than those of triploid (p<0.05). However, pH of triploid was higher than those of diploid (p<0.05), and oxygen consumption rate was not different between diploid and triploid (p>0.05). The level of plasma cortisol and plasma glucose of triploid was lower than those of the diploid (p<0.05). However, in case of lactic acid, there were not significant between triploid and diploid (p>0.05). These results suggest that diploid was more sensitive for low water temperature stress response than triploid in this species.

Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA)

  • Naji, Sahar Abdulrazzaq;Behroozibakhsh, Marjan;Kashi, Tahereh Sadat Jafarzadeh;Eslami, Hossein;Masaeli, Reza;Mahgoli, Hosseinali;Tahriri, Mohammadreza;Lahiji, Mehrsima Ghavvami;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.113-121
    • /
    • 2018
  • PURPOSE. The aim of this preliminary study was to investigate, for the first time, the effects of addition of titania nanotubes ($n-TiO_2$) to poly methyl methacrylate (PMMA) on mechanical properties of PMMA denture base. MATERIALS AND METHODS. $TiO_2$ nanotubes were prepared using alkaline hydrothermal process. Obtained nanotubes were assessed using FESEM-EDX, XRD, and FT-IR. For 3 experiments of this study (fracture toughness, three-point bending flexural strength, and Vickers microhardness), 135 specimens were prepared according to ISO 20795-1:2013 (n of each experiment=45). For each experiment, PMMA was mixed with 0% (control), 2.5 wt%, and 5 wt% nanotubes. From each $TiO_2$:PMMA ratio, 15 specimens were fabricated for each experiment. Effects of $n-TiO_2$ addition on 3 mechanical properties were assessed using Pearson, ANOVA, and Tukey tests. RESULTS. SEM images of $n-TiO_2$ exhibited the presence of elongated tubular structures. The XRD pattern of synthesized $n-TiO_2$ represented the anatase crystal phase of $TiO_2$. Moderate to very strong significant positive correlations were observed between the concentration of $n-TiO_2$ and each of the 3 physicomechanical properties of PMMA (Pearson's P value ${\leq}.001$, correlation coefficient ranging between 0.5 and 0.9). Flexural strength and hardness values of specimens modified with both 2.5 and 5 wt% $n-TiO_2$ were significantly higher than those of control ($P{\leq}.001$). Fracture toughness of samples reinforced with 5 wt% $n-TiO_2$ (but not those of 2.5% $n-TiO_2$) was higher than control (P=.002). CONCLUSION. Titania nanotubes were successfully introduced for the first time as a means of enhancing the hardness, flexural strength, and fracture toughness of denture base PMMA.

Monitoring and Analysis of Genetically Modified Ingredients of Imported Foods by PCR (PCR에 의한 수입식품의 유전자재조합 원료 분석 및 모니터링)

  • Kim, Hee-Yun;Park, Yong-Chjun;Ro, Hye-Lim;Jo, Jun-Il;Kim, Eun-Jung;Nam, Hae-Sun;Lee, Jin-Kyung;Lee, Jin-Ha;Kang, Yoon-Sook;Lee, Jong-Ook
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.605-608
    • /
    • 2006
  • Genetically modified (GM) ingredients found in imported raw materials and processed foods were monitored in the province Gyeongin in Korea. The analysis was performed according to "Testing methods for genetically modified foods of food standards and specifications" established in Korea. We received 120 items from the Gyeongin Regional KFDA. Only two of the 120 items analyzed in the samples, were contaminated with GM ingredients. However, we could not analyze the internal standard gene from 12 processed foods. We found that the extracted total DNA of the above 12 samples were extracted and found to be degraded. The total DNA contained a very small fragment of less than 300 base pair. Therefore, it seems that the total DNA is not large enough to serve as the template DNA for PCR analysis.

TEMPERATURE CHANGES IN THE PULP ACCORDING TO VAR10US RESTORATIVE MATERIALS AND BASES DURING POLISHING PROCEDURE (연마시 여러 가지 수복재와 이장재의 사용에 따른 치수내 온도변화)

  • Baik, Byeong-Ju;Lee, Doo-Cheol;Kim, Mi-Ra;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.410-418
    • /
    • 2000
  • An in vitro study was performed to evaluate the effect of four variables on the temperature rise produced by polishing of restorations. The four variables were : restorative material, base, thickness of remaining dentin, continuous polishing or intermittent polishing. Class V cavities were cut on extracted molar and restored with composite resin, resin-modified glass ionomer cement, compomer, amalgam on the various bases (glass ionomer cement, zinc oxide eugenol cement, zinc phosphate cement) Dentin thickness under the restoration was 0.5mm, 1.5mm. Polishing was done with an aluminum oxide-coated disc. Polishing time was continuous or intermittent for up to 1 minute. Intra-pulpal temperature increased almost linearly in all cases. Amalgam produced highest temperature rises at the pulp, while the composite resin, resin-modified glass ionomer cement and compomer were not different for each other. The rate and extent of temperature rising of amalgam restoration was reduced by presence of a cement base. Zinc oxide eugenol cement bases showed the highest temperature rise, while glass ionomer cement, zinc phosphate cement were not different to the untreated tooth Thickness of remaining dentin was only significant for the amalgam restoration. Continuous polishing produced higher temperature rise than intermittent polishing.

  • PDF

Fabrication and Characteristics of Epoxy Resin-Type Based Neutron Shielding Materials (에폭시수지계 중성자 차폐재 제조 및 특성)

  • Cho, Soo-Haeng;Kim, Ik-Soo;Do, Jae-Bum;Ro, Seung-Gy;Park, Hyun-Soo
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.457-463
    • /
    • 1998
  • New neutron shielding materials, KNS-201, KNS-301 and KNS-601 have been fabricated to be used for radioactive material shipping and storage cask. The base materials are a modified and a hydrogenated bisphenol- A type and novolac type epoxy resin, and aluminium hydroxide and boron carbide are added. These shielding materials offer good fluidity at processing, which makes it possible to form this resin shield into complicated geometric shapes such as radioactive material shipping and storage cask. Several measurements were made for the shielding materials to evaluate the thermal and mechanical properties and radiation resistance. The properties of the shielding materials are as follows: onset temperatures 2S7~28$0^{\circ}C$, thermal conductivities 0.9S~1.14W/m. K, thermal expansion coefficients 0.77~1.26x$10_{-6}{\circ}C_{-1}$, combustion characteristics < 80$0^{\circ}C$, ATB(average time of burning) < 5sec, AEB(average extent of burning) < 5mm, tensile strengths 2.5~3.2kg/$\textrm{mm}^2$, compressive strengths 13.2~1S.2kg/$\textrm{mm}^2$, flexural strengths 5.2 -6.4kg/$\textrm{mm}^2$. In general, the concerned properties of KNS-201, KNS-301 and KNS-601 were revealed to be better than those of NS-4- FR. foreign neutron shielding material. It is also observed that the radiation resistance of KNS- 601 was better than those of KNS-201 and KNS-301.

  • PDF

A COMPARATIVE EXPERIMENTAL STUDY ON THE SURFACE CHARACTERISTICS AND THE FITTNESS OF THE RESILIENT DENTURE LINES (탄성 의치상 이장재의 표면 특성 및 적합도에 관한 비교 실험 연구)

  • Lee, Soo-Back;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.137-154
    • /
    • 1987
  • The purpose of this investigation was to determine the surface characteristics and the fittness of the resilienct denture lines. Firstly, 50 samples ($2.0{\times}4.0{\times}0.3cm$) of 4 resilient lining materials (Molloplast B, Coe Super Soft, Mollosil, Coe Soft) and one conventional acrylic resin (K-33) were processed according to manufacture's direction and examined the surface characteristics by use of surface profilometer and scanning electron microscopy. Secondly, 50 identical maxillary casts were made and 50 denture bases were pro cessed of 4 resilient liners and one conventional acrylic resin and they were stored in the room temperature water bath of 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks and 6 weeks after processing. The original casts were cut away 1 cm from the posterior border, the dentures were seated, and the existing space was measured at seven regions according to the storage time by use of the modified thickness guage. The results were as follows. 1. Surface roughness (Rz) were $4.00{\pm}1.60{\mu}m$ in Mollosil, $4.47{\pm}2.21{\mu}m$ in Molloplast B, $7.46{\pm}1.70{\mu}m$ in Coe Super Soft, $12.70{\pm}2.39{\mu}m$ in Coe Soft and $13.03{\pm}2.74{\mu}m$ in K-33. 2. The generation of porosity was far more active in cold-cured resilient liners (Coe Soft and Mollosil) than in heat cured resilient liners (Molloplast B, and Coe Super Soft) and conventional heat cured resin (K-33). 3. Denture bases showed the greatest discrepancy at the central portion of the posterior palatal border and the intimate contact in the buccal flange regardless of denture base materials. 4. When the denture bases were stored in the water for 1 day and 6 weeks after processing, the sum of average discrepancies in the seven regions of the denture base was the greatest in K-33 followed by Molloplast B, Mollosil, Coe Soft and Coe Super Soft but followed by Coe Soft, Molloplast B, Mollosil, Coe Super Soft in that order respectively. 5. There was not a significant difference (p>0.05) in Coe Super Soft, K-33 but there was a significant difference (P<0.01) in Molloplast B, Mollosil, Coe Soft at the amount of dimensional changes according to the storage time.

  • PDF

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.

COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS (강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구)

  • Park, Hye-Yang;Oh, Nam-Sik;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR (구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향)

  • Lee, Kang;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

A Study on the Field Application of Superior Recycled Pavement of the Waste Asphalt (고품질 재활용 아스팔트 혼합물의 현장적용성에 대한 연구)

  • Kim, Jiwon;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.67-73
    • /
    • 2012
  • Asphalt pavement waste can be recycled by crushing and heating methods with additional virgin materials and additives. In this study, a new additive using Sasol wax and Polyolefin elastomer was used for improving the quality of the Superior recycled asphalt pavement(SRP). Additive was added into the recycled mixture by 1.5% and 3% of binder content in order to have PG 70-22 and PG 76-22. Both mixtures were tested by Marshall apparatus, indirect strength testing methods, toughness testing methods, moisture susceptibility testing methods and wheel tracking testing methods. Test results met the standards of KS F 2349 and GR F 4005. Through research, it was found that these special recycled mixtures could be applied for the surface and base course of heavy traffic roads or equivalents. About 13,000 tons of the recycled mixture has been applied on Seoul Olympic road to provide new road to Hangang park for Seoul citizens.