• 제목/요약/키워드: model B3

Search Result 3,811, Processing Time 0.031 seconds

Effect of Ethanol on the Protolytic Properties of the Vitamins B Group

  • Ghasemi, J.;Shiri, F.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • A multiwavelength spectrophotometric titration method was applied to study protolytic constants of four water-soluble vitamins, folic acid(vitamin B9 or B0), thiamine(vitamin B1), riboflavin(vitamin B2) and pyridoxal (vitamin B6) in binary ethanol-water mixtures at 25oC and an ionic strength of 0.1M NaNO3. The protolytic equilibrium constants, spectral profiles, concentration diagrams and also the number of components has been calculated from the curve fitting of the pH-absorbance data with appropriate mass balance equations by an established factor analysis model. DATAN program was used for determination of acidity constant and SPECFIT program was used for calculation of standard deviations and partial correlation coefficients. A glass electrode calibration procedure based on the four parameter equation pH=α+SpcH+JH+[H+]+ JOH-Kw/[H+] based on the Gran,s plots was used to obtain pH-readings in the concentration scale (pcH). The effect of the solvent on the protolytic constants was discussed.

A redistribution model for spatially dependent Parrondo games (공간의존 파론도 게임의 재분배 모형)

  • Lee, Jiyeon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.1
    • /
    • pp.121-130
    • /
    • 2016
  • An ansemble of N players arranged in a circle play a spatially dependent Parrondo game B. One player is randomly selected to play game B, which is based on the toss of a biased coin, with the amount of the bias depending on states of the selected player's two nearest neighbors. The player wins one unit with heads and loses one unit with tails. In game A' the randomly chosen player transfers one unit of capital to another player who is randomly chosen among N - 1 players. Game A' is fair with respect to the ensemble's total profit. The games are said to exhibit the Parrondo effect if game B is losing and the random mixture game C is winning and the reverse-Parrondo effect if game B is winning and the random mixture game C is losing. We compute the exact mean profits for games B and C by applying a state space reduction method with lumped Markov chains and we sketch the Parrondo and reverse-Parrondo regions for $3{\leq}N{\leq}6$.

Population Phenology and an Early Season Adult Emergence model of Pumpkin Fruit Fly, Bactrocera depressa (Diptera: Tephritidae) (호박과실파리 발생생태 및 계절초기 성충우화시기 예찰 모형)

  • Kang, Taek-Jun;Jeon, Heung-Yong;Kim, Hyeong-Hwan;Yang, Chang-Yeol;Kim, Dong-Soon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.4
    • /
    • pp.158-166
    • /
    • 2008
  • The pumpkin fruit fly, Bactrocera depressa (Tephritidae: Diptera), is one of the most important pests in Cucurbitaceae plants. This study was conducted to investigate the basic ecology of B. depressa, and to develop a forecasting model for predicting the time of adult emergence in early season. In green pumpkin producing farms, the oviposition punctures caused by the oviposition of B. depressa occurred first between mid- and late July, peaked in late August, and then decreased in mid-September followed by disappearance of the symptoms in late September, during which oviposition activity of B. depressa is considered active. In full-ripened pumpkin producing farms, damaged fruits abruptly increased from early Auguest, because the decay of pumpkins caused by larval development began from that time. B. depressa produced a mean oviposition puncture of 2.2 per fruit and total 28.8-29.8 eggs per fruit. Adult emergence from overwintering pupae, which was monitored using a ground emergence trap, was first observed between mid- and late May, and peaked during late May to early June. The development times from overwintering pupae to adult emergence decreased with increasing temperature: 59.0 days at $15^{\circ}C$, 39.3 days at $20^{\circ}C$, 25.8 days at$25^{\circ}C$ and 21.4 days at $30^{\circ}C$. The pupae did not develop to adult at $35^{\circ}C$. The lower developmental threshold temperature was calculated as $6.8^{\circ}C$ by linear regression. The thermal constant was 482.3 degree-days. The non-linear model of Gaussian equation well explained the relationship between the development rate and temperature. The Weibull function provided a good fit for the distribution of development times of overwintering pupae. The predicted date of 50% adult emergence by a degree-day model showed one day deviation from the observed actual date. Also, the output estimated by rate summation model, which was consisted of the developmental model and the Weibull function, well pursued the actual pattern of cumulative frequency curve of B. depressa adult emergence. Consequently, it is expected that the present results could be used to establish the management strategy of B. depressa.

A 14b 100MS/s $3.4mm^2$ 145mW 0.18um CMOS Pipeline A/D Converter (14b 100MS/s $3.4mm^2$ 145mW 0.18un CMOS 파이프라인 A/D 변환기)

  • Kim Young-Ju;Park Yong-Hyun;Yoo Si-Wook;Kim Yong-Woo;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.5 s.347
    • /
    • pp.54-63
    • /
    • 2006
  • This work proposes a 14b 100MS/s 0.18um CMOS ADC with optimized resolution, conversion speed, die area, and power dissipation to obtain the performance required in the fourth-generation mobile communication systems. The 3-stage pipeline ADC, whose optimized architecture is analyzed and verified with behavioral model simulations, employs a wide-band low-noise SHA to achieve a 14b level ENOB at the Nyquist input frequency, 3-D fully symmetric layout techniques to minimize capacitor mismatch in two MDACs, and a back-end 6b flash ADC based on open-loop offset sampling and interpolation to obtain 6b accuracy and small chip area at 100MS/s. The prototype ADC implemented in a 0.18um CMOS process shows the measured DNL and INL of maximum 1.03LSB and 5.47LSB, respectively. The ADC demonstrates a maximum SNDR and SFDR of 59dB and 72dB, respectively, and a power consumption of 145mW at 100MS/s and 1.8V. The occupied active die area is $3.4mm^2$.

Retrieval Spectral Albedo using red and NIR band of SPOT/VGT

  • Lee, Chang Suk;Seo, Min Ji;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.3
    • /
    • pp.367-373
    • /
    • 2014
  • Albedo is one of the critical parameters for understanding global climate change and energy/water balance. In this study, we used red and NIR reflectance from Satellite Pour I'Obervation de la Terre (SPOT)/Vegetation (VGT) S1 product. The product is preprocessed for users that they are atmospherically corrected using Simple Method Atmospheric Correction (SMAC) by Vision on Technology (VITO) for calculating broadband albedo. Roujean's Bi-directional Reflectance Distribution Function (BRDF) model is a semi-empirical method used for BRDF angular integration and inversion. Each kernel of Roujean's model was multi integrated by angle components (i.e., viewing zenith, solar zenith, and relative azimuth angle). Black-sky hemispherical function is integrated by observational angle; whereas, white-sky hemispherical efficient is integrated by incident angle. Estimated spectral albedo of red ($0.61{\sim}0.68{\mu}m$, B2) and near infrared ($0.79{\sim}0.89{\mu}m$, B3) have a good agreement with MODIS albedo products.

Numerical Analysis on the Frosting Performance of a Fin-tube Evaporator for a Refrigerator (냉장고용 핀-튜브 증발기의 착상 성능해석에 관한 연구)

  • Lee, Moo-Yeon;Lee, Ho-Sung;Jang, Yong-Hee;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.307-316
    • /
    • 2008
  • The objective of this study is to provide numerical and experimental data that can be used to investigate the performance characteristics of a flat plate fin-tube evaporator in household and commercial refrigerators under frosting conditions. Computer simulations with variations of operating conditions such as air inlet temperature, relative humidity, and geometries were performed to find out optimal design parameters of a fin-tube evaporator for household and commercial refrigerators. The tube-by-tube method was used in the simulation and the frost growth model was considered under frosting conditions. The developed analytical model predicted the decreasing rates of heat transfer capacity and air flow rate ratio within ${\pm}$10% compared to the experimental results for a refrigerator under real operating conditions. As a result, the frost thickness at $3^{\circ}C$ & 80% is increased 40% than that of $-3^{\circ}C$ & 80%, and the frost thickness at $3^{\circ}C$ & 90% is increased 30% than that of $3^{\circ}C$ & 60%. Accordingly, the operating time of the evaporator in the refrigerator was reduced with the increase of the decreasing rate of air flow rate ratio at each condition.

Performance Enhancement Directional CSMA/CA Algorithm in mmWave Bands (밀리미터파 대역에서 지향성 CSMA/CA의 성능 향상을 위한 알고리즘)

  • Kim, Mee-Joung;Lee, Woo-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1B
    • /
    • pp.15-20
    • /
    • 2012
  • In this paper, an algorithm that enhances the conventional directional CSMA/CA protocol in IEEE 802.15.3c is proposed under saturation environments. For the algorithm, a Markov chain model is presented and analyzed in no-ACK mode. The effects of directional antennas and the features of IEEE 802.15.3c MAC are considered in the model. The optimal sizes of contention window are derived from the numerical results. The numerical results show that the proposed directional CSMA/CA algorithm outperforms conventional one. The overall analysis is verified by simulation. The obtained results provide the criterion for selecting the optimal parameters and developing a MAC protocol that enhances the performance of mmWave WPANs.

Modeling of Smog Characteristics in Seoul during the Fall,1993 (서울시의 1993년 가을 스모그 특성모사)

  • 백남준;이성준;김용표;문길주;조영일
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.137-145
    • /
    • 1994
  • A visibility analysis model based on the Mie theory is applied to the measurements during the fall, 1993 in Seoul. Model estimations of the total extinction coefficient $b_{ext}$, and the particle scattering coefficient, $b_{sp}$ are in good agreement with the measured values by a transmissometer and a nephelometer, respectively. These values show strong dependency on the mass loading of fine particles( $D_{p}$ <3.0${\mu}{\textrm}{m}$) but show no apparent relation with that of coarse particles(3.0${\mu}{\textrm}{m}$$D^{p}$ <10${\mu}{\textrm}{m}$). Relative humidity plays an important role in determining the size of particles which in turn, affects the optical efficiency of aerosol. Based on the composition analysis with cut size nitrate concentration is higher than the sulfate concentration in PM3-10 but they are comparable to each other in PM3. Considering in 1985, it demonstrates a drastic increase of nitrate concentration between 1985 and 1993. It is found that measured and estimated light extinction budget were in good agreement within 10% and that scattering by particles is responsible for about 50-55% and 70-80 % of total extinction during clear and smoggy periods respectively.y.

  • PDF

3-D Analysis of Temperature Distribution in Transformers (변압기의 3차원 온도분포 해석)

  • 오연호;송기동;선종호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.9
    • /
    • pp.434-441
    • /
    • 2003
  • This paper deals with the temperature characteristics according to the cooling medium and the duct size in model transformers. For the analysis and the temperature-rise tests, two 400kVA model transformers have been manufactured. One has been filled with the alpha oil as the cooling medium and constructed the duct sizes of $3\textrm{mm}$ and $5\textrm{mm}$ in the low-voltage and high-voltage windings respectively. The other has been filled the beta oil and the duct sizes were $4\textrm{mm}$ and $6\textrm{mm}$. The temperature-rise tests have been performed by the back-to-back method and the load factor has been controlled the range of 90%∼130%. The temperature values have been measured by the thermocouple and from the sixteen points in each transformer. A commercial CFD program "FLUENT" has been used for the analysis of temperature distribution. The geometry of transformer has been modeled to 3-dimensional by using the hybrid calculation mesh including the radiator. And also, the natural convection velocity has been measured at the oil top position, and compared with the calculated results.

Discharge Coefficient of Side Weir for Various Curvatures Simulated by FLOW-3D (FLOW-3D를 이용한 다양한 곡률에 대한 횡월류 위어의 유량계수 산정)

  • Jeong, Chang Sam
    • Journal of Korean Society of Disaster and Security
    • /
    • v.8 no.1
    • /
    • pp.5-13
    • /
    • 2015
  • In this study, the lateral overflow discharge coefficients for the curvatures of side weir on meandering channel were analyzed. The side weir installed in accordance with the variation of the radius of curvature of the central angle bends with $180^{\circ}$. FLOW-3D model is applied to calculate the discharge coefficients of the side-weir on meandering and straight channels and the characteristics of the discharge coefficients are analysed. In order to verify the numerical model, the results from the hydraulic experiment conducted by the former research are compared with the results simulated by FLOW-3D in the same conditions. The discharge coefficients are calculated for the ratio between curvature ($R_c$) and channel width (b), and the ratio between over flow discharge of the straight channel ($Q_{wc}$) and the meandering channel ($Q_{wc}$) are compared. As the result, the discharge coefficients depend on the weir depth on upstream, and the radius of curvature, so that the discharge coefficients of side weir on the meandering channel can be estimated by them on the straight channel.