• 제목/요약/키워드: mode switching level

검색결과 101건 처리시간 0.02초

3-레벨 인버터의 누설전류 제거를 위한 캐리어 기반 MVPWM의 과변조 특성 (Overmodulation Characteristics of Carrier Based MVPWM for Eliminating the Leakage Currents in Three-Level Inverter)

  • 이은철;최남섭;안강순
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.509-516
    • /
    • 2015
  • The overmodulation characteristics of a carrier-based medium vector pulse width modulation (CBMVPWM) are examined in this study. CBMVPWM can completely eliminate leakage currents in a three-phase, three-level inverter using only the switching states with the same common mode voltage even in an overmodulation operation. The analytic equations for the magnitude of the output voltage and the switching frequency are derived for overmodulation operation, and the effect of dead time on the leakage current is demonstrated. This study presents the operating principle of CBMVPWM, basic overmodulation features, and simulations and experiments for operating verification.

Tap Level 제어 전력 변환기의 권선설계 (A winding design of Tap Level Converter)

  • 전중함;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.53-55
    • /
    • 2006
  • In this paper discusses winding methode of single phase AC-DC reversible power converter The reversible power converter driven by multi Tap winding at both side switching control. It has a advantage that simple drive of main switching device. and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

바이어스 스위칭을 이용한 이중 모우드 전력 증폭기 효율 개선 (Efficiency Improvement for Dual Mode Amplifier Design Using Bias Switching)

  • 이영민;구경헌
    • 대한전자공학회논문지TC
    • /
    • 제43권8호
    • /
    • pp.97-102
    • /
    • 2006
  • 본 논문은 이중 모우드 송신기에서 효율을 증가시킬 수 있는 새로운 기법을 제시하였다. 미래의 이중 모우드 송신기는 다른 주파수 대역에서 서로 다른 출력을 갖는 증폭기로 구성되어 진다. 와이브로는 2.3GHz 대역에서 1W의 출력을 갖고 무선랜은 2.4GHz에서 100mW의 출력전력을 갖는다. 본 논문은 단순한 바이어스 스위칭 방법으로 위 두 시스템에서 각각 높은 효율을 얻을 수 있음을 제안하였다. 바이어스 스위칭을 사용하지 않은 증폭기의 경우 20dBm의 출력을 갖는 무선랜 주파수 대역에서 효율이 10%로 나타났으나 바이어스 스위칭을 사용하게 된다면 더 낮은 바이어스에서 35%의 효율을 나타내었다. 따라서 이 기술은 더욱 많은 기능이 융합되는 미래의 다중 대역 단말시스템에 매우 유용할 것이다.

Random PWM 기법을 이용한 3상 승압형 컨버터 전도노이즈 저감에 관한 연구 (A study on the Conducted Noise Reduction in Three-Phase Boost Converter using Random Pulse Width Modulation)

  • 정동효
    • 전기학회논문지P
    • /
    • 제51권3호
    • /
    • pp.120-125
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. Generally, to reduce the EMI and improve the immunity of converter system, the switching frequency of converter needs to be properly modulated during a rectified line period instead of being kept constant. Random Pulse Width Modulation (RPWM) is performed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%~30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

멀티레벨 인버터를 이용한 3상 유도전동기 구동 시스템의 EMI 필터 설계 (Design of EMI filters for an Induction Motor Drive System with Multi-level inverters)

  • 김수홍;안영오;방상석;김광섭;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.265-270
    • /
    • 2006
  • In this paper EMI problems with induction motor drive system using multi-level inverters are investigated. The high power multi-level inverter usually operates with low switching frequency and produces large noises. Generally, EMI consists of the conduction component through source lines and emission component emitted to the space. This conduction component can be classified to the common-mode between source line and ground, and the normal-mode between lines. The EMI filters for the induction motor drive system are designed and implemented to reduce EMI noise. Finally the designed system is verified by the experiment. The experimental results show that both the normal mode and common mode noises are greatly reduced compared to the system without filters.

3-Level T-type Inverter Operation Method Using Level Change

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.263-269
    • /
    • 2018
  • In this study, a selective inverter operation between a 2-level voltage source converter (VSC) and a 3-level T-type VSC (3LT VSC) is proposed to improve the efficiency of a 3LT VSC. The 3LT VSC topology, except for its neutral-point switches, has similar operations as that of the 2-level VSC. If an operation mode is changed according to efficiency, the efficiency can be improved because efficiencies of each methods are depending on current and MI (Modulation Index). The proposed method calculates the power losses of the two topologies and operates as the having lower losses. To calculate the losses, the switching and conduction losses based on the operation mode of each topology were analyzed. The controller determined the operation mode of the 2- or 3-level VSC based on the power loss calculated during every cycle. The validity of the proposed control scheme was investigated through simulation and experiments. The waveform and average efficiency of each method were compared.

UPFC의 스위칭레벨 상세 모의 및 동적 특성 고찰 (Study of Dynamic Characteristics of an UPFC Switching-Level Model)

  • 원동준;김선호;한학근;이송근;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1287-1289
    • /
    • 1999
  • The UPFC(Unified Power Flow Controller) controls the magnitude and phase of the series injected voltage to exchange the real and reactive power with transmission line. The UPFC consists of two inverters connected together through the DC link capacitor. This paper describes the detailed UPFC switching-level model. PWM (Pulse Width Modulation) method is chosen to operate the inverters. Automatic voltage control mode and automatic power flow control mode is selected to control the UPFC. EMTP simulation is offered to obtain the basic operation characteristics of the UPFC and the dynamic characteristics of the UPFC is studied in detail.

  • PDF

RVEGA SMC를 이용한 이중 탱크의 수위 제어 (Control of Coupled Tank Level using RVEGA SMC)

  • 김태우;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.104-111
    • /
    • 2000
  • It is very difficult to maintain the desired tank level without any overflow or any shortage in a dangerous shemical plant and in a cooling one. Futhermore, because its dynamics are very complicate and nonlinear, it is impossible to realize the precise control using the accurate mathematical model which can be applied to the various peration modes. Nonetheless, the sliding mode controller(SMC) is known as having the robust variable structures for the nonlinear control system with the parametric perturbations and with the rapid disturbances. But the adaptive tuning algorithms for their parameters are not satisfactory. Therefore, in this paper, a Real Variable Elitist Genetic Algorithm based Sliding Mode Controller (RVEGA SMC) for the precise control of the coupled tank level was tried. The SMC's switching parameters were optimized easily and rapidly by RVEGA. The simulation results showed that the tank level could be satisfactorily controlled without and overshoot and any steady-state error by the proposed RVEGA SMC.

  • PDF

GA-SMC를 이용한 이중 탱크의 정밀한 수위 제어 (Control of Coupled Tank Level using GA-SMC)

  • 박현철;지석준;정종원;최우진;이준탁
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.239-244
    • /
    • 2002
  • Even though, tanks are used at the many industry plants, it is very difficult to control the tank level without any overflow and shortage; moreover, cause of its complication of dynamics and nonlinearity, it's impossible to realize the accurate control using the mathematical model which can be applied to the various operation modes. However, the sliding mode controller(SMC) is known as having the robust variable structures for the nonlinear control systems with the parametric perturbations and with the sudden disturbances, but the auto-tuning of parameters was a problem. Therefore, in this paper, a Genetic Algorithm based Sliding Mode Controller (GA-SMC) for the precise control of the coupled tank level was tried. GA optimized the SMCs switching parameters easily and rapidly. The simulation results are shown that the tank level could be satisfactorily controlled with less overshoot and steady-stale error by the proposed GA-SMC.

  • PDF

Random PWM 기법을 이용한 전도노이즈 저감 (A study on the Conducted Noise Reduction in Random PWM)

  • 정동효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.154-158
    • /
    • 2006
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. Random Pulse Width Modulation (RPWM) is peformed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300v/1kW with $5%{\sim}30%$ white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF