• Title/Summary/Keyword: mode determination

Search Result 515, Processing Time 0.025 seconds

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

Simultaneous Determination of Benzoic Acid, Caffeic Acid and Chlorogenic Acid in Seeds of Eriobotrya japonica and their Antibacterial Effect

  • Jeong, Jun-Mo;Lee, Kyoung-In;Kim, Sun-Min
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.1
    • /
    • pp.89-93
    • /
    • 2014
  • We aim to develop a simple method for simultaneous and quantitative determination of benzoic acid, caffeic acid and chlorogenic acid in seeds of Eriobotrya japonica. In addition, antibacterial effect of these three phenolic acids was examined. A basic method is performed on the high performance liquid chromatography system coupled to an UV-detector (230 nm) and reverse phase C-18 column ($4.6{\times}150mm$, $5{\mu}m$). Each phenolic acid was confirmed via liquid chromatography-mass spectrometry (MS)/MS system under the multiple-reaction monitoring with negative-ion electrospray ionization (ESI(-)) mode. It is demonstrated that the method was could be applied to samples for an analytical study of the phenolic acids. On the other hand, three phenolic acids in seeds of E. japonica exhibited antibacterial effect against several pathogenic bacteria. Of these, benzoic acid was found to have stronger antibacterial effect.

Determination of $k_1$in Elliptic Crack under General Ioading Conditions (타원균열에 작용하는 일반적인 하중에서의 응력확대계수 계산)

  • An, Deuk-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.232-244
    • /
    • 1997
  • In this paper weight function theory is extended to the determination of the stress intensity factors for the mode I in elliptic crack. For the calculation of the fundamental fields Poisson's theorem and Ferrers's method were employed. Fundamental fields are constructed by single layer potentials with surface density of crack harmonic fundamental polynimials. Crack harmonic fundamental polynimials up to order four were given explicitly. As an example of the application of the weight function theory the stress intensity factors along crack tips in nearly penny-shaped elliptic crack are calculated.

Part-Per-Trillion level determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water

  • Kim, Hyub
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.149-149
    • /
    • 2003
  • A new technique is proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert.-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the GC/MS-SIM mode. The recoveries were 86.6∼105.2 % (isoBOC derivatization) and 97.6∼484.5 % (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol A for SIM were 0.001∼0.050 $\mu\textrm{g}$/l (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/l (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). The derivative methods and their application to tap water samples will be disscussed.

  • PDF

Determination of cable force based on the corrected numerical solution of cable vibration frequency equations

  • Dan, Danhui;Chen, Yanyang;Yan, Xingfei
    • Structural Engineering and Mechanics
    • /
    • v.50 no.1
    • /
    • pp.37-52
    • /
    • 2014
  • The accurate determination of cable tension is important to the monitoring of the condition of a cable-stayed bridge. When applying a vibration-based formula to identify the tension of a real cable under sag, stiffness and boundary conditions, the resulting error must not be overlooked. In this work, by resolving the implicit frequency function of a real cable under the above conditions numerically, indirect methods of determining the cable force and a method to calculate the corresponding cable mode frequency are investigated. The error in the tension is studied by numerical simulation, and an empirical error correction formula is presented by fitting the relationship between the cable force error and cable parameters ${\lambda}^2$ and ${\xi}$. A case study on two real cables of the Shanghai Changjiang Bridge shows that employing the method proposed in this paper can increase the accuracy of the determined cable force and reduce the computing time relative to the time required for the finite element model.

Determination of Member Force Ratios for Self-equilibrium State of Multi-Layered Cable Dome Type Structures (다층 케이블 돔형 구조물의 자기평형을 위한 부재력 비율 결정)

  • Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.2
    • /
    • pp.75-82
    • /
    • 2013
  • For each cable component in a cable dome structure, pre-tension is needed for stability of whole the structure. The summation of these pre-tension at each joint should be zero to achieve the self equilibrium structure. The first step in cable dome structure analysis is to find the ratio of pre-tension in each member which can produce a stable and structure on self-equilibrium. In this paper, a new method based on the basic principle of closed force polygon for equilibrium system is proposed for the determination of self-equilibrium mode of cable dome structure. A single layer cable dome and two multi layer type domes have been analyzed. The ratios of cable members are determined by the presented method, and check the validation of the results by numerical calculation.

Determination of Ultratraces of Rhodium by Adsorptive Stripping Voltammetry of Formaldehyde Complex

  • Hong Tae-Kee;Czae Myung-Zoon;Lee Chul;Kwon Young-Soon;Hong Mi-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1035-1037
    • /
    • 1994
  • An ultrasensitive and selective stripping voltammetric scheme for the determination of rhodium is described. By the use of combined accumulation and catalytic effects in formaldehyde-hydrochloric acid medium, substantial improvement in the limit of detection can be obtained. Optimal experimental conditions were found to be 0.42 M hydrochloric acid solution containing 0.008${\%}$ formaldehyde, an accumulation potential of -0.70 V (vs. Ag/AgCl) and an accumulation time of 20 s. The stripping mode was differential pulse voltammetry. In these conditions the limit of detection lies at 2 ${\times}$ l0$^{-12}$ M (0.21 ppt). The relative standard deviation at 5 ${\times}$ l0$^{-11}$ M was 4.9${\%}$ (n=5). There were no serious interferences from other platinum group metal ions being the tolerable amounts more than 500 times that of rhodium.

Simultaneous determination of corticosteroids in a herbal medicinal preparation by GC-MS

  • Jeong, Jae-Chul;Kim, Jin;Kim, Mee-Jung;Choi, Don-Woong;Chang, Seung-Yeup;Im, Moon-Kyo;Paeng, Ki-Jung
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.395.2-395.2
    • /
    • 2002
  • The determination method for 11 corticosteroids (betamethasone, cortisol. cortisone, cortisone acetate. dexamethasone. cortisol acetate, isoflupredone acetate, methylprednisolone. prednisone, prednisolone, and triamcinolone acetonide) in a herbal medicinal preparation (Sibjeondaibotang) by a gas chromatography-mass spectrometric (GC-MS) method with selected ion monitoring (SIM) mode is described. Samples (4 mL) were extracted by liquid-liquid extraction with diethyl ether. (omitted)

  • PDF

Determination of a Novel Antiangiogenic Agent KR-31831 in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry

  • Kim, Sook-Jin;Lee, Seung-Seok;Ji, Hye-Young;Lee, Hong-Il;Lee, Seon-Kyoung;Yi, Kyu-Yang;Yoo, Seong-Eun;Hwang, Jeong-Sook;Lee, Hye-Suk
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.217.2-217.2
    • /
    • 2003
  • A liquid chromatography-tandem mass spectrometric (LC/MS/MS) method was developed for the determination of a new anti-angiogenic drug KR-31831 in rat plasma. KR-31831 and internal standard, KR-31543 were extracted from rat plasma with dichloromethane at basic pH. A reverse-phase LC separation was performed on Luna C8 column with the mixture of acetonitrile-ammonium formate (10 mM, pH 4.5) (67:33, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. (omitted)

  • PDF

Determination of Grayanotoxin I and Grayanotoxin III in mad honey from Nepal using liquid chromatography-tandem mass spectrometry

  • Ahn, Su Youn;Kim, Suncheun;Cho, Hwangeui
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.82-91
    • /
    • 2022
  • Grayanotoxin-contaminated honey exhibits toxicity. In this study, a reliable and sensitive liquid-chromatography-tandem-mass-spectrometric method (LC-MS/MS) was developed and validated for the quantitation of grayanotoxin I and grayanotoxin III in honey. The grayanotoxins were extracted from honey via solid phase extraction and separated on a biphenyl column with a mobile phase consisting of 0.5 % acetic acid in water and methanol. Mass spectrometric detection was performed in the multiple-reaction monitoring mode with positive electrospray ionization. The calibration curve covered the range 0.25 to 100 ㎍/g. The intra- and inter-day deviations were less than 10.6 %, and the accuracy was between 94.3 and 114.0 %. The validated method was successfully applied to the determination of grayanotoxins in mad honey from Nepal. The concentrations of grayanotoxin I and grayanotoxin III in 33 out of 60 mad honey samples were 0.75 - 64.86 ㎍/g and 0.25 - 63.99 ㎍/g, respectively. The method established herein would help in preventing and confirming grayanotoxin poisoning.