• Title/Summary/Keyword: modal analysis method

Search Result 1,169, Processing Time 0.024 seconds

A Study on the Vibrational Characteristics of the Continuous Circular Cylindrical Shell with the Multiple Supports Using the Experimental Modal Analysis (실험모드해석에 의한 다점지지된 연속원통셸의 진동특성에 관한 연구)

  • 한창환;이영신
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.4
    • /
    • pp.43-51
    • /
    • 2001
  • An experimental modal analysis is the process to identify structure's dynamic characteristics such as resonant frequencies, damping values and mode shapes. An experimental model was made of stainless steel in the shape of a circular cylindrical shell and installed on the test bed with jigs. For investigating vibrational characteristics of the continuous circular cylindrical shell with intermediate supports, modal testing is performed by using impact hammer, accelerometer and 8-channel FFT analyzer. The frequency response function(FRF) measurements are also made on the experimental model within the frequency range from 0 to 4kHz. Modal parameters are identified from resonant peaks in the FRF's and animated deformation patterns associated with each of the resonances are shown on a computer screen. The experimental results are compared with analytical and FEA results.

  • PDF

Modal Parameter Estimation of a Steel Frame Structure by Using Free Vibration Displacement Data (자유진동 변위데이터를 이용한 철골구조물의 모드인자 파악)

  • Ham, Hee-Jung
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.19-25
    • /
    • 2009
  • The proper orthogonal decomposition (POD) analysis of vibration of a steel frame structure is performed to extract modal parameters. The theoretical background of the POD method is introduced briefly, and this technique is further applied to free vibration displacements of one bay-two story steel frame structure to extract the modal parameters. From the POD analysis of the steel frame structure, it is found that important modal parameters such as true mode shapes, modal kinematic energy, natural frequencies, and damping ratios can be obtained for the building efficiently and in detail. Therefore, it is concluded that the POD method could be one of the useful techniques in analysis of vibration of structures.

  • PDF

Modal analysis of eccentric shells with fluid-filled annulus

  • Jhung, Myung Jo;Jeong, Kyeong Hoon;Hwang, Won Gul
    • Structural Engineering and Mechanics
    • /
    • v.14 no.1
    • /
    • pp.1-20
    • /
    • 2002
  • Investigated in this study are the modal characteristics of the eccentric cylindrical shells with fluid-filled annulus. Theoretical method is developed to find the natural frequencies of the shell using the finite Fourier expansion, and their results are compared with those of finite element method to verify the validation of the method developed. The effect of eccentricity on the modal characteristics of the shells is investigated using a finite element modeling.

Output only structural modal identification using matrix pencil method

  • Nagarajaiah, Satish;Chen, Bilei
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.395-406
    • /
    • 2016
  • Modal parameter identification has received much attention recently for their usefulness in earthquake engineering, damage detection and structural health monitoring. The identification method based on Matrix Pencil technique is adopted in this paper to identify structural modal parameters, such as natural frequencies, damping ratios and modal shapes using impulse vibration responses. This method can also be applied to dynamic responses induced by stationary and white-noise inputs since the auto- and cross-correlation function of the two outputs has the same form as the impulse response dynamic functions. Matrix Pencil method is very robust to noise contained in the measurement data. It has a lower variance of estimates of the parameters of interest than the Polynomial Method, and is also computationally more efficient. The numerical simulation results show that this technique can identify modal parameters accurately even if the noise level is high.

Uncertainty in Operational Modal Analysis of Hydraulic Turbine Components

  • Gagnon, Martin;Tahan, S.-Antoine;Coutu, Andre
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.278-285
    • /
    • 2009
  • Operational modal analysis (OMA) allows modal parameters, such as natural frequencies and damping, to be estimated solely from data collected during operation. However, a main shortcoming of these methods resides in the evaluation of the accuracy of the results. This paper will explore the uncertainty and possible variations in the estimates of modal parameters for different operating conditions. Two algorithms based on the Least Square Complex Exponential (LSCE) method will be used to estimate the modal parameters. The uncertainties will be calculated using a Monte-Carlo approach with the hypothesis of constant modal parameters at a given operating condition. In collaboration with Andritz-Hydro Ltd, data collected on two different stay vanes from an Andritz-Hydro Ltd Francis turbine will be used. This paper will present an overview of the procedure and the results obtained.

Definition and calculation method of modal effective mass of asymmetric fluid-structure interaction system for seismic analysis

  • Yong-Hwa Heo;Jong-Oh Sun;Gyeong Ho Kim;Yeonseok Choo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4307-4316
    • /
    • 2023
  • In this paper, modal effective mass for asymmetric fluid-structure interaction system is defined and equations for its calculation is derived. To establish consistency, modal effective mass in symmetric structure only system is briefly reviewed, followed by a definition of the modal effective mass in asymmetric system. The equations for calculating modal effective mass in asymmetric system are derived by utilizing the properties of left and right eigenvectors. To simplify the equations, the assumption is made that the mass matrix is only affected by the fluid. The simplified equation is then compared to the equation already used in ANSYS. Finally, the validity of the modal effective mass definition and derivation in this paper is demonstrated through a simple example.

Experimental Modal Analysis using Proportional Viscous.Hysteretic Damping System on the Rolling Stock (비례점성.히스테리시스 감쇠계에 의한 철도차량의 실험모드해석)

  • 최문길;김창남;김의간
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.86-91
    • /
    • 1996
  • In this study, the modal analysis is adopted for the investigation of vibratory characteristics of a rolling stock. A governing equation for this system is deverived on a condition that the rolling stock is in proportional viscous damping and proportional hysteretic damping. By applying this method a computational modal analysis software is developed. The validity and reliability of this method is verified by comparing the results for the above case and with those of a system having proportional viscous damping and a system having general viscous damping. A system that has non-linearity, an error from the calculation may occur in the analysis. In this case, we applied the piecewise linear method to estimate the modal parameters.

  • PDF

A Vibration Mode Analysis of Resilient Mounting System and Foundation Structure of Acoustic Enclosure using Finite Element Method (유한요소법을 이용한 음향차폐장치용 탄성마운트 시스템 및 받침대의 진동모드 해석)

  • 정우진;배수룡;함일배
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.493-501
    • /
    • 1999
  • The vibration modes of resilient mounting system and foundation structure which support diesel engine/generator set and acoustic enclosure walls play an important role in the vibration transmission process. So, it is necessary to perform vibration mode analysis of resilient mounting system and foundation structure. For some reasons, if the vibration modal analysis of resilient mounting system and foundation structure of acoustic enclosure could be simultaneously done by finite element method, it would be very efficient approach. In this paper, vibration modal analysis method using finite element method for multi stage mounting system having n d.o.f model was proposed. Vibration analysis of single and double stage resilient mounting system was performed to verify the validity of the proposed method. Also frequency response results were compared in case of rigid foundation model and finite element foundation model which was compared with experimental modal analysis results.

  • PDF

Noncontact Modal Testing Method Using Magnetostriction Effects (마그네토스트릭션 효과를 이용한 비접촉 모달 테스팅 기법)

  • Cho, Seung-Hyun;Lee, Ho-Chul;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.701-707
    • /
    • 2000
  • In this work, we propose to employ magnetostrictive sensors to develop a new non-contacting modal testing method. Specific applications are made in the modal testing of a beam in bending. The role of bias magnetic fields in measuring bending waves is addressed and an approximate analysis to explain the principle to measure bending signals is carried out. The measured modal data by the present method agree well with those by conventional methods using accelerometers.

  • PDF

Model Updating Method Based on Mode Decoupling Controller with Incomplete Modal Data (불완전 모달 정보를 이용한 모드 분리 제어기 기반의 모델 개선법)

  • Ha, Jae-Hoon;Park, Youn-Sik;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.963-966
    • /
    • 2005
  • Model updating method is known to the area to correct finite element models by the results of the experimental modal analysis. Most common methods in model updating depend on a parametric model of the structure. In this case, the number of parameters is normally smaller than that of modal data obtained from an experiment. In order to overcome this limitation, many researchers are trying to get modal data as many as possible to date. 1 want to name this method multiple modified-system generation method. These Methods consist of direct system modification method and feedback controller method. The direct system modification Is to add a mass or stiffness on the original structure or perturb the boundary conditions. The feedback controller method is to make the closed food system with sensor and actuator so as to get the closed loop modal data. In this paper, we need to focus on the feedback controller method because of its simplicity. Several methods related the feedback controller methods are virtual passive controller (VPC) sensitivity enhancement controller (SEC) and mode decoupling controller (MDC). Among them, we will apply MDC to the model updating problem. MDC has various advantages compared with other controllers, such as VPC and SEC. To begin with, only the target mode can be changed without changing modal property of non-target modes. In addition, it is possible to fix any modes if the number of sensors is equal to that of the system modes. Finally, the required control power to achieve desired change of target mode is always lower than those of other methods such as VPC. However, MDC can make the closed loop system unstable when using incomplete modal data. So we need to take action to avoid undesirable instability from incomplete modal data. In this paper, we address the method to design the unique and robust MDD obtained from incomplete modal data. The associated simulation will be Incorporated to demonstrate the usefulness of this method.

  • PDF