• Title/Summary/Keyword: mixing ratio change

Search Result 305, Processing Time 0.027 seconds

Experimental Study on Fuel/Air Mixing using Inclined Injection in Supersonic Flow (경사 분사에 의한 초음속 유동 연료-공기 혼합에 관한 실험적 연구)

  • Lee, Dong-Ju;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.9-15
    • /
    • 2009
  • The flow of combustor in scramjet engine has supersonic speed so that the residence time and mixing ratio are very important factors for the efficient combustion. This study used open cavity(L/D=4.8) as a fuel/air mixing model. Laser schlieren visualization and pressure measurement were carried out to observe the flow characteristics around a jet orifice and a cavity at the time of fuel injection. As a result of 10ns laser schlieren, unsteady flow which was around the cavity could be observed effectively. Pressure was measured that momentum flux ratio(J) was changed. And the change of critical ignition point could be observed by the momentum flux ratio changed.

A change of local meteorological environment according to dam construction of Nakdong-River -II. Estimation using numerical model- (낙동강 수계 중의 댐 건설에 의한 주변의 국지기상환경 변화 -II. 수치모델을 이용한 추정-)

  • 전병일;이영미
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.281-288
    • /
    • 2002
  • This study was carried out for reading the change of local meteorological environment according to dam construction of Nakdong-river using numerical model. The study used PSU/NCAR Mesoscale Model version5(MM5) for inquiring effect of formation of artificial lake after dam construction. The colleague simulated temperature mixing ratio, latent heat flux and sensible heat flux in two cause of existing lake and not. Temperature and mixing ratio in southwest of Andong lake increased because of the air that was warm and moist above the lake moved to southwest due to the northeasterly wind. In the case of existing lake around Andong, latent heat flux increased much in the daytime after sunrise. However, sensible heat flux decreased but it didn't change distinctly in southwest of Andong like the other values.

The Study on Application of Aerated Concrete as a Filling Material for Special Use (특수용도 충전재로서 기포콘크리트의 활용성에 관한 연구)

  • 허재원;이종필;김효열;임남기
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.45-50
    • /
    • 2004
  • In this study, we processed two procedures of application test of filler for special-purpose utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

  • PDF

Study on the Beating Properties of CMC Pre-treated and Mixed Cotton Linter Pulp (제지용 면 펄프의 CMC 전처리 및 혼합 고해특성 연구)

  • Shin, Hyeon-Sik;Lee, Jin-Ho;Kim, Duk-Ki;Park, Jong-Moon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.4
    • /
    • pp.11-20
    • /
    • 2014
  • The objective of this study was to investigate the beating properties of two types of cotton pulps such as "cotton lint mixed pulp" and "cotton linter pulp". In order to improve refining characteristics, the effects of carboxymethyl-cellulose (CMC) pre-treatment, mixing ratio changes of cotton lint mixed pulp and cotton linter pulp, and refining load changes were analyzed. In mill application, it was possible to improve the refining characteristics and maintained the strength properties of the paper by applying increasing ratio of cotton linter pulp mixing and controlling the refining methods.

A Study on Changes in Pore Water Quality of Polluted Sediment due to Mixing Ratio of Granulated Coal Ash (석탄회 조립물 혼합비율에 따른 오염 퇴적물의 간극수 수질 변화에 관한 연구)

  • Lee, In-Cheol;Woo, Hee-Eun;Kim, Kyeongmin;Lee, Jun-Ho;Kim, Kyunghoi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.5
    • /
    • pp.201-206
    • /
    • 2018
  • This study investigated the changes in pore water quality of polluted sediment by mixing ratio of granulated coal ash. The mesocosm experiments were carried out with 0%, 10%, 30% and 50%, respectively, of the material mixture ratio relative to the sediments. According to the results of the experiments, pH increased depending on the mixing ratio. Phosphate and ammonia concentrations were significantly decreased in the mixing ratio of 30% and 50% compared to the control (p < 0.05). The concentration of hydrogen sulfide was reduced by 72% at the mixing ratio of 10%, and it was not detected at the mixing ratio of 30% and 50%. This study was confirmed that granulated coal ash can change the pore water quality of polluted sediments in proportion to the amount of material. However, the effect of the mixing ratio between 30% and 50% was not significantly different, thus it is concluded that mixing of 30% of the volume of the sediment is economically feasible.

The Strength Evaluation of Al5083-O GMA Welding Zone According to the Heat Input and Mixing Shield Gas Ratio (Al5083-O GMA 용접부의 입열량과 보호가스 혼합비율에 따른 강도 평가)

  • 이동길;양훈승;정재강
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.158-165
    • /
    • 2002
  • This study was to evaluate mechanical properties and toughness of the Al5083-O aluminum alloy welding zone according to the mixing shield gas ratio and heat input change. The GMA(Gas Metal Arc) welding of the base metal was carried out with four different mixing shield gas ratios(Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%) and three different heat inputs(low, medium, and high). To investigate the Charpy absorbed energy of the weld zone, the specimens were divided base metal, weld metal, fusion line, and HAZ notched specimen according to the worked notch position. The different gas ratio and heat input had little effect upon the tensile strength. But Ar33%+He67% mixture had the greatest mechanical properties considering that the more He gas ratio concentrations, the higher yield strength and elongation. The maximum load and displacement of the weld metal notche specimen was so much low more than that of the base metal, but fusion line and HAZ notched specimens showed almost same regardless of the mixing shield gas ratio and heat input. The Charpy absorbed energy was lowest in weld metal notched specimen, and increased in the fusion line, and HAZ notche specimen in order. Ar33%+He67% mixture had the greatest toughness considering that the more He gas ratio, the higher absorption energy.

Experimental Reinforcement Agent for Damaged Walls of Payathonzu Temple Murals in Bagan, Myanmar

  • Lee, Na Ra;Lee, Hwa Soo;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.36 no.4
    • /
    • pp.284-295
    • /
    • 2020
  • This study focuses on reinforcement agents for wall damage, such as cracks, breakage, or delamination, for mural paintings from the Payathonzu temple. Experiments were conducted with filling and grouting agents based on the reinforcing method. In the filling reinforcement experiment, different mixing ratios of lime to sand, and additives (jaggery, seaweed glue, and Primal SF-016) were used. In the grouting reinforcement experiment, the mixing ratio of lime and pozzolan was the same, and the additive types were identical to the filling reinforcement experiment. The filling reinforcement experiment showed that there were fewer physical changes such as contraction, with a greater mixing ratio of lime to sand, however, the compressive strength decreased as the mixing ratio increased. With additives, the change in volume of agent decreased and the compressive strength increased, which was especially prominent for jaggery and Primal SF-016. The grouting reinforcement experiment showed that there was a remarkable contraction with an increased amount of moisture that originates from the characteristic of grouting agents that requires flowability. With additives, the water content of the agent decreased, whereas the compressive strength and adhesion increased. Among the additives, Primal SF-016 exhibited the highest compressive strength, and seaweed glue exhibited the most considerable viscosity and adhesion. The study results showed that the characteristics of reinforcement agents vary according to the mixing ratio and additives of the filling and grouting agents. Therefore, it is necessary to selectively apply the mixing ratio and additives for different reinforcement agents considering the wall damage for conservation treatments.

Study on Characteristics of Biogas Production and Liquid Fertilizer with Anaerobic Co digestion of Livestock Manure and Food Waste (혐기성소화에서 가축분뇨와 음식물쓰레기의 혼용에 따른 바이오가스 생산 및 소화액의 액비 특성 연구)

  • Park, Woo-Kyun;Park, Noh-Back;Shin, Joung-Du;Hong, Seung-Gil;Kwon, Soon-Ik;Kang, Kee-Kyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.895-902
    • /
    • 2011
  • Objective of this research was to investigate the characteristics of biogas production in anaerobic digestion reactor with different mixing ratio of food waste and swine manure. It was observed that the highest removal efficiency of organic material was 80% at 60 : 40 of mixing ratio (livestock manure : food waste). And also biogas yield was varied due to different mixing ratio of them. The cumulative biogas yield was highest at 60 : 40 of mixing rate (livestock manure : food waste). For use of the liquefied fertilizer as effluent from anaerobic digester, it was the limited ratio for 30% of co-digested food waste based on its salt content.

Influence of Cement and Mixing time Factor on the Bleeding of Concrete (콘크리트의 블리딩에 미치는 시멘트 및 믹싱시간의 영향)

  • Lee, Won-Am;Um, Tai-Sun;Lee, Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.593-596
    • /
    • 2008
  • The bleeding of concrete is defined as a kind of separation of materials. The durability of concrete, as well as the quality caused by the bleeding. Therefore, This study is intended to find influence of cement and mixing time factor on the bleeding of concrete. We want to know two factors that determine the change, to provide it to our customers. According to the results, The bleeding ratio increase by the increase of mixing time factor. At the 90 second of mixing time, the amount of bleeding differ greatly from cement properties. This paper presents an experimental study on bleeding ratio, slump and compressive strength properties with three days. In addition, the mixing time is inversely related slump loss ratio, the initial value of the compressive strength is only affected by the mixing time. As a result, the bleeding of concrete was obtained that their characteristics depends on the cement and mixing time factor, also in the future, to derive optimum mixing time for a variety of review is necessary.

  • PDF

Analysis of Mechanical Properties of Colored EPDM Based on Additive Mixing Ratio Using Mixture Design of Experimental Method (혼합물 실험계획법을 이용한 유색 EPDM의 첨가제 배합비에 따른 기계적 특성 분석)

  • Park, Yoon-A;Jeon, Euy-Sik;Kim, Young-Shin;Lee, Hyun-Seung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.8
    • /
    • pp.79-86
    • /
    • 2022
  • With the recent increase in the demand for electric vehicles, it is necessary to identify the high current safety of automobile parts. Among the automobile parts, the EPDM parts required colored parts from the existing black; therefore, it was necessary to change the basic filler from carbon black to silica. The rubber used in automobile parts is flexible and exhibits basic characteristics of high strength and elongation. However, as the filler is changed to silica, its physical properties, such as tensile strength and elongation, are lower than those of the existing carbon black base. Therefore, it is necessary to evaluate the mechanical properties with the addition of the EPDM compound using silica as a base without degrading the physical properties of EPDM. In this study, an experiment based on the additive content was performed using the mixture experimental planning method to analyze the mechanical properties according to the additive type and mixing ratio of silica-based EPDM. The mixing ratio of the four additives was set using a simplex lattice design, and the tensile strength, elongation, modulus 300%, and permanent compression reduction rate were analyzed for mechanical characteristics, and rheometer experiments were performed for vulcanization characteristics. Through statistical analysis of the measured data, the main effects and interactions of the EPDM-blended rubber additives were analyzed. These results can be used to derive a mixing ratio of additives that satisfies the required characteristics of the EPDM compound.