• Title/Summary/Keyword: mirror imaging

Search Result 118, Processing Time 0.026 seconds

SNU Research Activities with United Kingdom Infrared Telescope

  • Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • From 2009, CEOU of Seoul National University has been utilizing the United Kingdom Infrared Telescope (UKIRT) at Mauna Kea, Hawaii, as one of its research facilities. UKIRT is a telescope with 3.8m primary mirror, and it is currently the largest telescope specialized for infrared observations. We will summarize our research activities using UKIRT, which include Infrared Medium-deep Survey (IMS) of proto-clusters and high redshift quasars, NIR imaging programs of Gamma Ray Bursts (GRBs), Gamma Ray sources, and SNUQSO quasars. Our research programs include international collaboration with the UK GRB team, the NASA/Swift team, Pomona College, and National Central University of Taiwan. We will also touch on our future plan of using UKIRT.

  • PDF

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.

Imaging System Wavefront Analysis Using Ronchi Test

  • Lee, Sunwoo;Park, Woojin;Yu, Joonkyu;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.56.2-56.2
    • /
    • 2018
  • Ronchi test is an optical test to check the quality of an imaging system. Wavefront of the optical system can be obtained from the Ronchi patterns. In this poster, we present the Ronchi test module and the optical quality evaluation results. The test module consists of a light source, a pinhole, a beam splitter, a Ronchi ruling and a flat mirror. The test module can be simply adapted to any optical systems. We compare measured surface data for both aluminum and glass parabolic mirrors by analyzing the Ronchi patterns.

  • PDF

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF

Demonstration of the Usefulness of Optical Coherence Tomography in Imaging a Mouse Tail Model of Lymphedema

  • Kim, Hui Dong;Kim, Dong Kyu;Chae, Yu-Gyeong;Park, Seok Gyo;Kim, Ghi Chan;Jeong, Ho Joong;Sim, Young-Joo;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.132-137
    • /
    • 2017
  • To investigate the usefulness of optical coherence tomography (OCT) for imaging lymphedema, we directly compared it to other histological methods in a mouse model of lymphedema. We performed detailed imaging of the lymphedema lesion on a mouse tail. We imaged the mouse tail in vivo with OCT and created histopathological samples. We constructed a spectrometer-based OCT system using a fiber-optic Michelson interferometer. The light was directed to 50:50 couplers that split the light into reference and sample arms. Backscattered light from a reference mirror and the sample produced an interference fringe. An OCT image of the lymphedema model revealed an inflammatory reaction of the skin that was accompanied by edema, leading to an increase in the light attenuation in the dermal and subcutaneous layers. Similar to OCT image findings, histological biopsy showed an inflammatory response that involved edema, increased neutrophils in epidermis and subdermis, and lymphatic microvascular dilatation. Furthermore, the lymphedema model showed an increase in thickness of the dermis in both diagnostic studies. In the mouse tail model of lymphedema, OCT imaging showed very similar results to other histological examinations. OCT provides a quick and useful diagnostic imaging technique for lymphedema and is a valuable addition or complement to other noninvasive imaging tools.

Realization of Infrared Thermograph System (적외선 체열촬영시스템의 구현)

  • 이수열;우응제;조민형
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.13-24
    • /
    • 1994
  • In the conventional thermograph systems, expensive infrared lens systems are usually used for accomodating infrared beams to high speed optical scanners. In this study, a cheap focussing mirror with a two dimensional scanner are used for the development of medical infrared thermograph system in which high speed imaging is not critically required. The infrared thermograph system can be used for two dimensional imaging of human skin temperature by measuring the amount of infrared lights radiating from it. It has been experimentally proven that the accuracy of temperature measurements using the developed system is under 0.1$^{\circ}C$ with image matrix size of 256${\times}$240, and imaging time of 4 seconds.

  • PDF

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

Two-step Holographic Imaging Method based on Single-pixel Compressive Imaging

  • Li, Jun;Li, Yaqing;Wang, Yuping;Li, Ke;Li, Rong;Li, Jiaosheng;Pan, Yangyang
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.146-150
    • /
    • 2014
  • We propose an experimental holographic imaging scheme combining compressive sensing (CS) theory with digital holography in phase-shifting conditions. We use the Mach-Zehnder interferometer for hologram formation, and apply the compressive sensing (CS) approach to the holography acquisition process. Through projecting the hologram pattern into a digital micro-mirror device (DMD), finally we will acquire the compressive sensing measurements using a photodiode. After receiving the data of two holograms via conventional communication channel, we reconstruct the original object using certain signal recovery algorithms of CS theory and hologram reconstruction techniques, which demonstrated the feasibility of the proposed method.