• Title/Summary/Keyword: minimum energy control

Search Result 275, Processing Time 0.025 seconds

Hybrid Reference Function for Stable Stepwise Inertial Control of a Doubly-Fed Induction Generator

  • Yang, Dejian;Lee, Jinsik;Hur, Kyeon;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.86-92
    • /
    • 2016
  • Upon detecting a frequency event in a power system, the stepwise inertial control (SIC) of a wind turbine generator (WTG) instantly increases the power output for a preset period so as to arrest the frequency drop. Afterwards, SIC rapidly reduces the WTG output to avert over-deceleration (OD). However, such a rapid output reduction may act as a power deficit in the power system, and thereby cause a second frequency dip. In this paper, a hybrid reference function for the stable SIC of a doubly-fed induction generator is proposed to prevent OD while improving the frequency nadir (FN). To achieve this objective, a reference function is separately defined prior to and after the FN. In order to improve the FN when an event is detected, the reference is instantly increased by a constant and then maintained until the FN. This constant is determined by considering the power margin and available kinetic energy. To prevent OD, the reference decays with the rotor speed after the FN. The performance of the proposed scheme was validated under various wind speed conditions and wind power penetration levels using an EMTP-RV simulator. The results clearly demonstrate that the scheme successfully prevents OD while improving the FN at different wind conditions and wind power penetration levels. Furthermore, the scheme is adaptive to the size of a frequency event.

A Dynamic Server Power Mode Control for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 동적 서버 전원 모드 제어)

  • Kim, Ho-Yeon;Ham, Chi-Hwan;Kwak, Hu-Keun;Kwon, Hui-Ung;Kim, Young-Jong;Chung, Kyu-Sik
    • The KIPS Transactions:PartC
    • /
    • v.19C no.2
    • /
    • pp.135-144
    • /
    • 2012
  • All the servers in a traditional server cluster environment are kept On. If the request load reaches to the maximum, we exploit its maximum possible performance, otherwise, we exploit only some portion of maximum possible performance so that the efficiency of server power consumption becomes low. We can improve the efficiency of power consumption by controlling power mode of servers according to load situation, that is, by making On only minimum number of servers needed to handle current load while making Off the remaining servers. In the existing power mode control method, they used a static policy to decide server power mode at a fixed time interval so that it cannot adapt well to the dynamically changing load situation. In order to improve the existing method, we propose a dynamic server power control algorithm. In the proposed method, we keep the history of server power consumption and, based on it, predict whether power consumption increases in the near future. Based on this prediction, we dynamically change the time interval to decide server power mode. We performed experiments with a cluster of 30 PCs. Experimental results show that our proposed method keeps the same performance while reducing 29% of power consumption compared to the existing method. In addition, our proposed method allows to increase the average CPU utilization by 66%.

A study on lighting Diffusion system of Daylight Duct System (광덕트방식 자연채광 시스템의 산광부에 대한 연구)

  • Song, Kyu-Ryol;Park, Gyeong-Woo;Ryu, Han-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

Improved Single-Stage AC-DC LED-Drive Flyback Converter using the Transformer-Coupled Lossless Snubber

  • Jeong, Gang-Youl;Kwon, Su-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.644-652
    • /
    • 2016
  • This paper presents an improved single-stage ac-dc LED-drive flyback converter using the transformer-coupled lossless (TCL) snubber. The proposed converter is derived from the integration of a full-bridge diode rectifier and a conventional flyback converter with a simple TCL snubber. The TCL snubber circuit is composed of only two diodes, a capacitor, and a transformer-coupled auxiliary winding. The TCL snubber limits the surge voltage of the switch and regenerates the energy stored in the leakage inductance of the transformer. Also, the switch of the proposed converter is turned on at a minimum voltage using a formed resonant circuit. Thus, the proposed converter achieves high efficiency. The proposed converter utilizes only one general power factor correction (PFC) control IC as its controller and performs both PFC and output power regulation, simultaneously. Therefore, the proposed converter provides a simple structure and an economic implementation and achieves a high power factor without the need for any separate PFC circuit. In this paper, the operational principle of the proposed converter is explained in detail and the design guideline of the proposed converter is briefly shown. Experimental results for a 40-W prototype are shown to validate the performance of the proposed converter.

Prediction of the Blast Wave Propagation Over a Kick Motor Test Facility (Kick Motor 시험장 충격파 전파 예측)

  • Ok, Ho-Nam;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.220-223
    • /
    • 2008
  • A test facility to measure the performance of a KM(Kick Motor) is constructed, and prediction of blast wave propagation over the facility is performed to check if the safety of test personnel in MCC(Main Control Center) can be guaranteed even for the most severe explosion. Assuming that the initial explosion energy is contained in a sphere under the pressure of 500, 1000, 1500 psi, respectively, the radius of the sphere is determined for each pressure to set the mass of contained explosion gas to 35 kg. The material properties of explosion gas are set to be the ones of KM propellant combustion gas under normal condition. To reduce the effort and time required for a complex three-dimensional modeling, the flowfield is approximated to axismmetry. Calculations are performed for all three initial pressure conditions, and the analysis of the result is given for 1500 psi which is expected to be the worst case. The maximum pressure is 3.5 psig while the minimum pressure is -1.2 psig on the outer wall of MCC, and the maximum pressure difference between the inner and outer walls of protection wall amounts to 3.0 psi.

  • PDF

Design of Structure Corners restraining Tribological Failures: Part II - Analysis of Design Parameters and Examples (트라이볼로지 손상을 억제하기 위한 구조물 모서리부 설계: 제2부 - 설계인자 분석 및 예)

  • Kim, Hyung-Kyu
    • Tribology and Lubricants
    • /
    • v.31 no.4
    • /
    • pp.170-176
    • /
    • 2015
  • As a continuation of Part I, which developed a design formula of the minimum corner radius (Rmin) for restraining tribological failures, Part II investigates design parameters such as material properties and contact force. As design examples, Al 7075-T651, SST 304 and HT-9 are chosen for the materials and 1, 10 and 100 kN are used for the forces. The results show that the difference in Rmin decreases as either the elastic modulus increases or the contact force decreases. Given the same material and force, the permissible Rmin decreases as the flat region increases and vice versa. Because the Rmin values obtained from the examples are very small, the dimensions of the corner radius normally designed in engineering structures are regarded acceptable. The von Mises stress evaluated for a typical example, which is far below the yield strength, confirms this interpretation. Nevertheless, the present work can provide a design criterion as well as a guideline for quality control in the manufacturing of, in particular, contact corners, which has not been attempted before to the best of the author’s knowledge. In addition, this paper considers the problem of a step that may be formed in the contact contour by using a similar approach. The result shows that no size of the step is permissible.

Pulsed-laser-diode Intermittently Pumped 2-㎛ Acousto-optic Q-switched Tm:LuAG Laser

  • Wen, Ya;Jiang, Yan;Zheng, Hao;Zhang, Hongliang;Wang, Chao;Wu, Chunting;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.238-246
    • /
    • 2020
  • The heat distribution in crystals in a 2-㎛ acousto-optic Q-switched Tm:LuAG laser pumped by pulsed-laser-diode (pulsed-LD) intermittent-pumping technology was analyzed using COMSOL software. The thermal lensing effect of the Tm:LuAG crystal can be mitigated by pulsed-LD intermittent-pumping techniques. An experimental setup using this kind of approach achieved maximum output energy of 8.31 mJ, minimum pulse width of 101.9 ns, and highest peak power of 81.55 kW, reached at a Q-switched repetition rate of 200 Hz. It offers significant improvement of performance of the output laser beam, compared to pulsed-LD double-ended pumping technology at the same repetition rate.

Application of rate-controlled sintering into the study of sintering behavior of boron carbide (탄화붕소 소결 거동 연구를 위한 율속제어소결의 적용)

  • Lee, Hyukjae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.1
    • /
    • pp.6-12
    • /
    • 2015
  • Under rate-controlled sintering, furnace power is controlled to maintain a specific specimen contraction rate. This thermal processing method guarantees continuous process with a minimum thermal energy applied over time and makes it possible to control the density of the sintered body precisely. In this study, the rate-controlled sintering is applied to the sintering of $B_4C$ in order to investigate how rate-controlled sintering variables can affect the sintering behavior and/or grain growth behavior of $B_4C$ and how the results can be interpreted using sintering theories to draw an optimal sintering condition of the rate-controlled sintering. Further, the applicability of the rate-controlled sintering into the study for sintering of unknown materials is also considered.

A Study on Acceleration Characteristics for Automated Rail Mounted Crane (자동화크레인의 가속도 특성에 관한 연구)

  • Kim, Hwan-Seong;Kim, Myeong-Kyu;Tran Ngoc, Hoang Son
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.10a
    • /
    • pp.215-216
    • /
    • 2009
  • By growing the capacity of container in the world, main container terminal in countries introduces the automated container equipments and try to improve the productivity for handling the container. ARMC(Automated Rail Mounted Crane) is installed in automated container terminal and expected the high efficiency of productivity by using minimum-time control method. However recently by the GREEN Port policy, high energy efficiency method for container equipments is importance issue in ports. In this paper, the 3-dimensional modelling of AMRC is discussed and the acceleration characteristics for ARMC is analyzed By using the results of this paper, the advanced controller for the crane will be developed in future.

  • PDF

An Optimal Placement of passive Constrained Layer Damping Treatment for Vibration Suppression of Automotive Roof (차량루프의 진동저감을 위한 수동구속감쇠처리의 위치 최적화)

  • Lee, Ki-Hwa;Kim, Chan-Mook;Kang, Young-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.349-353
    • /
    • 2004
  • A study on optimal placement of constrained layer damping treatment for vibration control of automotive panels is presented. The effectiveness of damping treatment depends upon design parameters such as choice of damping materials, locations and size of the treatment. This paper proposes a CAE (Computer Aided Engineering) methodology based on finite element analysis to optimize damping treatment. From the equivalent modeling technique, it is found that the best damping performance occurs as the viscoelstic patch is placed by means of the modal strain energy method of bare structural panels to identify flexible regions, which in turn facilitates optimizations of damping treatment with respect to location and size. Different configurations of partially applied damping layer treatment have been analyzed for their effectiveness in realizing maximum system damping with minimum mass of the applied damping material. Moreover, simulated frequency response function of the automotive roof with and without damping treatments are compared, which show the benefits of applying damping treatment. Finally, the optimized damping treatment configuration is validated by comparing the locations and the size of the treatment with that of an experimental modal test conducted on roof compartment.

  • PDF