• Title/Summary/Keyword: minimum $F_0$

Search Result 279, Processing Time 0.03 seconds

Proposal of a New Design Method of the Pile-Bent Structure Considering Plastic Hinge (단일 현장타설말뚝의 소성힌지를 고려한 최적설계법 제안)

  • Ahn, Sang-Yong;Jeong, Sang-Seom;Kim, Jae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.91-101
    • /
    • 2011
  • In this study, a new design method of Pile-Bent structure considering plastic hinge was proposed on the basis of the beam-column model. To obtain the detailed informations, the optimized cross-section ratio between column and pile was analyzed to induce the plastic hinge at the joint section between the pile and column. Base on this study, the optimized diameter ratio of pile and column can be obtained below the inflection point of the bi-linear curve depending on the relations between column-pile diameter ratio ($D_c/D_p$) and normalized lateral cracking load ratio ($F/F_{Dc=Dp}$). Moreover, through comparisons with field cases to find out in-depth limit in which minimum concrete-steel ratio could be applied, in-depth limits ($L_{As=0.4%}$) normalized by the pile length ($L_p$) proportionally decrease as the pile length ($L_p/D_p$)increases up to $L_p/D_p=17.5$, and beyond that in-depth limit converges to a constant value (${\simeq}0.3$).

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

Annealing Effect on the Microwave Dielectric Properties of the BaO-SmS12TOS13T-TiOS12T Ceramics (BaO-Sm2O3-TiO2 세라믹스의 마이크로파 유전특성에 미치는 어닐링 효과)

  • Lee, Geun-Ill;Chung, Jang-Ho;Lee, Young-Hie
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.789-794
    • /
    • 1994
  • In this study, the structural and microwave dilelectric properties of 0.15BaO-0.15SmS12TOSI3T-0.7TiOS12T ceramics with sintering and annealing conditions were investigated. In the specimen sintered at 1350 [$^{\circ}C$], dielectric constant and quality factor were good values of 80.19,2006 (fS10T=4.6851[GHz]). To improve the $\tau$S1fT of specimen which was manufactured by the optimumsintering condition (1350[$^{\circ}C$],2[Hr.]), annealed from 2[hr.] to 16[hr.] at the annealing temperature of 1200 [$^{\circ}C$]. Increasing the annealing time, dielectric constant was almost constant and quality factor was increased. In the specimen of 4[hr.] annealed, the temperature coefficient of resonant frequency was minimum value, and increased with increasing the annealing time.

An Analysis of the Relationship between Climacteric Symptoms and Management of Menopause in Middle-aged Women (일 지역 중년여성의 폐경증상과 폐경관리와의 관계에 대한 연구)

  • Song, Ae-Ri
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.7 no.2
    • /
    • pp.308-322
    • /
    • 2001
  • The purpose of this study was to investigate the relationship between climacteric symptoms and management of menopause of middle -aged women. The subjects of this study were 261 women(40 to 60 years old). Data were collected from Jun. 1 to Jul. 15, 2001 by a structured questionnaire. The instruments employed were : 1) The Climacteric Symptoms Scale developed by Aeri Song and Eun soon Chung(1998). 2) The Management of Menopause Scale developed by Aeri Song(1997). The data were analyzed by the SPSS p.c. program using t-test, ANOVA and Pearson correlation coefficient. The results of the study were as follows : 1. Mean score of climacteric symptoms was $2.18{\pm}0.39$(Maximum 4, Minimum 1). The mean scores among the categories of climacteric symptoms, in descending order, were : a) physical and physiological reactions ($2.62{\pm}0.53$), b) social and family relationships ($2.23{\pm}0.50$), c) psychiatric and psychological reactions ($2.08{\pm}0.49$), d) relationship with sexual partner($1.73{\pm}0.54$), e) genitourinary reactions ($1.72{\pm}0.55$). 2. Mean score of management of menopause was $1.79{\pm}0.45$ (Maximum 4, Minimum 1). The mean scores among the categories of management of menopause, in descending order, were : a) dietary management($2.57{\pm}0.52$), b) self control ($2.24{\pm}0.57$), c) management of exercise and physical activity($2.14{\pm}0.75$), d) management of sex life($1.71{\pm}0.47$), e) management of professional health maintenance($1.61{\pm}0.59$). 3. There were statistically significant differences in the score of middle-aged women's self reported climacteric symptoms according to : a) occupation (t=-2.79, p<0.001) b) marriage state (t=-2.29, p<0.05) c) age of menarche (F=4.66, p<0.001) d) method of Sanhujori (post natal care & treatment) (F=4.22, p<0.001) e) hormone replacement therapy (t=-3.09, p<0.05). From the above statistics, several significant findings were noted : a) There were more climacteric symptoms from those who were unemployed, those who had no partner or were divorced and those who started a menarche earlier. b) There were less climacteric symptoms reported from those on hormone replacement therapy and those who followed their parents or parents-in-law advice regarding Sanhujori (postnatal care) 4. There were statistically significant differences in the score of middle-aged women's self reported management of menopause according to : The educational background (F=7.63, p<0.001), religion (F=3.74, p<0.001), income (F=3.65, p<0.001), number of parity (F=4.87, p<0.001), method of Sanhujori(postnatal care) (F=5.73, p<0.001), period of Sanhujori (postnatal care) (F=2.81, p<0.05), hormone replacement therapy (t=3.81, p<0.001). Women with higher educational background, strong religion, higher income, large number of parity, managed their post natal care well, were on HRT, managed their menopause significantly better than the others who took part in the survey. 5. It will be noted from the above that women's degree of climacteric symptoms showed a negative correlation to the management of menopause(r=-0.2146, p<0.001). The findings shown above suggest the need to develop a variable management of menopause, in order to improve climacteric symptoms of middle-aged women. It is hoped that the above findings will stimulate more detailed research into this matter, and thereby enable guidance to be given to women going through the menopause to cope with it in a less stressful way.

  • PDF

Partial molal volumes of n-alkylamine hydrochlorides in methanol-water mixtures (메탄올-물 혼합액에서의 n-Alkylamine 염산염의 분 몰랄 부피)

  • Uhm, Tae-Sup;Yoon, Sang-Ki;Lee, Ik-Choon
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.51-59
    • /
    • 1970
  • The apparent molal volumes(${\phi}_v$) of the homologous salts $RNH_3Cl$, where R varies from methyl-($CH_{3^-}$) to n-butyl-(n-$C_4H_{9^-}$) in a series of methanol-water mixtures have been determined at 30$^{\circ}C$ by means of a float method to fifth decimal places down to 0.01 m. The values of ${\phi}_r$ extrapolated to infinite dilution give partial molal volumes $\bar{V}^{\circ}$which varies considerably in accordance with the solvent composition. that is, mole fraction of methanol. The experimental results are discussed in terms of the varying size and charge effect, hydrophobic nature of the solute species, and also the additivity relationship between successive homologous and the structure of the binary solvent. The results indicate that at 0.1 mole fraction methanol the enhanced structuredness of water cause a minimum in the partial molal volumes of cations $\bar{V}^{\circ}_+$, while at 0.4 mole fraction the solvent structure is such that the free volume is a minimum but the effect of electrostriction is a maximum.

  • PDF

A Study on Conductance Behaviors of Amine Salts in the Binary Solvent Mixtures. Methylammonium Chlorides in Methanol-Water Mixtures at $25^{\circ}C$ (혼합용매계에 대한 아민염의 전기전도도에 관한 연구. 메탄올-물 혼합계에 대한 메틸암모늄염의 전도도)

  • Sang Kee Yoon;Bong Kyu Kim;Uhm Tae Seop;Jong Yul Park
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.3
    • /
    • pp.185-192
    • /
    • 1976
  • Equivalent conductances of ammonium salts such as $NH_4Cl,\;CH_3NH_3Cl,\;(CH_3)_2NH_2Cl,\;(CH_3)_3NHCl\;and\;(CH_3)_4NCl$ have been measured in methanol-water mixtures of various composition (0.0${\sim}$0.6-mole frcation: m. f.) in the concentration range from 0.01 to 0.04 M at $25^{\circ}C$, and limiting equivalent conductances (${\Lambda}_0$) are determined by the analysis of Fuoss Onsager's semiempirical equation.The experimental results are discussed in terms of varing the size of ${\Lambda}_0$ due to the salts species and solvent composition. It has been observed in quite common over all salts that ${\Lambda}_0$ decreases with the increase of m. f. methanol, and the maximum decrement in ${\Lambda}_0$ shows between water and 0.1 m. f., while the plot of ${\Lambda}_0$ vs. m. f. goes through a minimum at 0.4 m. f. and then turns slightly upward. On the other hand, the ${\Lambda}_0$ decrease with the increase of the size of ammonium cation and the larger values ${\Lambda}_0$ are showed in comparison with those of values observed for the corresponding $n-RNH_3Cl$ under the same experimental procedure. All these behaviors are considered to be closely correlated with the structures of solvents and solutes and the significant similarities are compared with the behaviors of partial molar volumes for amine salts in same solvent system.

  • PDF

Using Tabu Search for L(2,1)-coloring Problem of Graphs with Diameter 2 (Tabu Search를 이용한 지름이 2인 그래프에 대한 L(2,1)-coloring 문제 해결)

  • Kim, SoJeong;Kim, ChanSoo;Han, KeunHee
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.345-351
    • /
    • 2022
  • For simple undirected graph G=(V,E), L(2,1)-coloring of G is a nonnegative real-valued function f : V → [0,1,…,k] such that whenever vertices x and y are adjacent in G then |f(x)-f(y)|≥ 2 and whenever the distance between x and y is 2, |f(x)-f(y)|≥ 1. For a given L(2,1)-coloring c of graph G, the c-span is λ(c) = max{|c(v)-c(v)||u,v∈V}. L(2,1)-coloring number λ(G) = min{λ(c)} where the minimum is taken over all L(2,1)-coloring c of graph G. In this paper, based on Harary's Theorem, we use Tabu Search to figure out the existence of Hamiltonian Path in a complementary graph and confirmed that if λ(G) is equal to n(=|V|).

TREES WITH EQUAL STRONG ROMAN DOMINATION NUMBER AND ROMAN DOMINATION NUMBER

  • Chen, Xue-Gang;Sohn, Moo Young
    • Bulletin of the Korean Mathematical Society
    • /
    • v.56 no.1
    • /
    • pp.31-44
    • /
    • 2019
  • A graph theoretical model called Roman domination in graphs originates from the historical background that any undefended place (with no legions) of the Roman Empire must be protected by a stronger neighbor place (having two legions). It is applicable to military and commercial decision-making problems. A Roman dominating function for a graph G = (V, E) is a function $f:V{\rightarrow}\{0,1,2\}$ such that every vertex v with f(v)=0 has at least a neighbor w in G for which f(w)=2. The Roman domination number of a graph is the minimum weight ${\sum}_{v{\in}V}\;f(v)$ of a Roman dominating function. In order to deal a problem of a Roman domination-type defensive strategy under multiple simultaneous attacks, ${\acute{A}}lvarez$-Ruiz et al. [1] initiated the study of a new parameter related to Roman dominating function, which is called strong Roman domination. ${\acute{A}}lvarez$-Ruiz et al. posed the following problem: Characterize the graphs G with equal strong Roman domination number and Roman domination number. In this paper, we construct a family of trees. We prove that for a tree, its strong Roman dominance number and Roman dominance number are equal if and only if the tree belongs to this family of trees.

A Study on the Creep Fracture Life of Al 7075 Alloy(II) (Al 7075 합금의 크리이프 파단수명에 관한 연구(II))

  • 강대민
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.29-41
    • /
    • 1994
  • High temperature tensiles tests, steady state creep tests, internal stress tests and creep rupture tests using Al 7075 alloy were performed over the temperature range of 9$0^{\circ}C$~50$0^{\circ}C$ and stress range of 0.64~17.2(kgf/$\textrm{mm}^2$) in order to investigate the creep behavior and predict creep rupture life From the apparent activation energy Qc and the applied stress exponent n measured, at the temperature range of 9$0^{\circ}C$~l2$0^{\circ}C$, the creep deformation seemed to be controlled by cross slip. On the other hand at the temperature of 20$0^{\circ}C$~23$0^{\circ}C$ the creep deformation seemed to be controlled by dislocation climb but at 47$0^{\circ}C$~50$0^{\circ}C$, by diffusion creep. And the rupture life(t$_{f}$) might be represented by anthermal process attributed to the difference of the applied stress dependence of Internal stress and the ratio of the Internal stress to the applied stress, the thermal activated process attributied to the temperature dependence of the internal stress. Also the ratio between stress dependence of primary creep rate and that of minimum creep rate was measured 0.46, the minimum creep rate is expected to be appromately obtained from master creep curve including the relationship primary creep rate and minumum creep rate. Finally the relationship new rupture parameter and logarithmic stress was represented with including the ratio between the dependence of primary creep rate and that of minimum creep rate, using the new rupture parameter the rupture life predition is exactly expected.d.

  • PDF

Analysis of Cutting Properties with Reference to Amount of Coolant used in an Environment-Conscious Turning Process

  • Yang, Seung-Han;Lee, Young-Moon;Kim, Young-Suk
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2182-2189
    • /
    • 2004
  • In the recent years, environmentally conscious design and manufacturing technologies have attracted considerable attention. The coolants, lubricants, solvents, metallic chips and discarded tools from manufacturing operations will harm our environment and the earth's ecosystem. In the present work, the Tukey method of multiple comparisons is used to select the minimum level of coolant required in a turning process. The amount of coolant is varied in 270 designed experiments and the parameters cutting temperature, surface roughness, and specific cutting energy are carefully evaluated. The effects of coolant mix ratio as well as the amount of coolant on the turning process are studied in the present work. The cutting temperature and surface roughness for different quantity of coolant are investigated by analysis of variance (ANOVA) - test and a multiple comparison method. ANOVA-test results signify that the average tool temperature and surface roughness depend on the amount of coolant. Based on Tukey's Honestly Significant Difference (HSD) method, one of the multiple comparison methods, the minimum level of coolant is 1.0 L/min with 2% mix ratio in the aspect of controlling tool temperature. F-test concludes that the amount of coolant used does not have any significant effect on specific cutting energy. Finally, Tukey method ascertains that 0.5 L/min with 6% mix ratio is the minimum level of coolant required in turning process without any serious degradation of the surface finish. Considering all aspects of cutting, the minimum coolant required is 1.0 L/min with 6% mix ratio. It is merely half the coolant currently used i.e. 2.0 L/min with 10% mix ratio. Minimal use of coolant not only economically desirable for reducing manufacturing cost but also it imparts fewer hazards to human health. Also, sparing use of coolant will eventually transform the turning process into a more environment-conscious manufacturing process.