• Title/Summary/Keyword: miniature society

Search Result 571, Processing Time 0.025 seconds

A Study of Augmented Reality based Visualization using Shape Information of Building Information Modeling (BIM 형상정보를 이용한 증강현실기반 가시화 사례)

  • Heo, Kyung-Jin;Lee, Seok-Jun;Jung, Soon-Ki
    • Spatial Information Research
    • /
    • v.20 no.2
    • /
    • pp.1-11
    • /
    • 2012
  • In the current construction planning and designing process, an architectural miniature model was designed to verify the interior or exterior spatial sense of a building structure, but building of the miniature model is demand much more effort and time; in addition to this it has limitation to identify interior information of the building. For a complement of it, CAD would be used in the existing planning and designing process to visualize the building information, but its visualization is not satisfactory for the 3D volume which could be easily verified with the miniature model. CAD is the specific software for designing building structures and the 3D results are usually rendered on 2D monitor screen. Therefore, there is a shortage of cognitive immersion for the 3D space. In this paper, we introduce the conversion process of BIM shape data into the Augmented Reality contents by using a series of softwares. As a result of modification on construction plan or design we reduced the cost and time to reconstruct the final visualization. We have shown that the interior or exterior information of the building structures are easily visualized with BIM shape data on augmented reality environment. Several proposed interaction methods, such as rem oval of building components, and slice-cut operation, provide the user for the effective manipulation of models on the augmented reality environment.

Primary Dilated Cardiomyopathy in a Miniature Pinscher Dog (미니어쳐 핀셔견에서 발생한 확장성 심근질환)

  • Kim, Jung-Hyun;Park, Chul;Ko, Ki-Jin;Kang, Byeong-Teck;Jung, Dong-In;Kim, Ju-Won;Kim, Ha-Jung;Lim, Chae-Young;Lee, So-Young;Cho, Sue-Kyung;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.349-354
    • /
    • 2006
  • A 9-month-old, female Miniature Pinscher(MP) dog weighing 1.97kg was presented because of periodic syncopal episode for 5 months. This case was diagnosed as primary dilated cardiomyopathy based on respiratory distress history, weak femoral pulse, generalized cardiomegaly, pulmonary edema, marked dilation of left atrium(LA) and left ventricle(LV), decreased wall thickness of LV and interventricular septum(IVS), increased EPSS in echocardiography, and young age of onset in the absence of other cardiovascular disorders. The patient was stabilized by application of diuretics(Furosemide, 2 mg/kg, SC, q 1 hr) and venodilator(Nitroglycerine patch, 0.5 mg/kg, q 12 hrs). Clinical signs were improved with medical management of positive inotropic vasodilator(Pimobendan, 0.2 mg/kg, PO, q 12 hrs) and angiotensin-converting enzyme(ACE) inhibitor(benazepril, 0.5 mg/kg, PO, q 12 hrs), potassium gluconate gel(2 mEq/dog, PO, q 12 hrs) and, L-carnitine(50 mg/kg, PO, q 12 hrs). The dog still maintains stable clinical status 10 months after the first visit. We report the rare case of DCM in small breed dog, which corresponds to the diagnosis and treatment of typical DCM in large breed dog.

Initial Diagnosis of Acute Renal Failure Induced by Ischemia in Miniature Pig (미니돼지에서 허혈성 신장 손상의 조기진단)

  • Kim, Se-Eun;Ko, A-Ra;Bae, Chun-Sik;Park, Soo-Hyun;Han, Ho-Jae;Shim, Kyung-Mi;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.52-56
    • /
    • 2011
  • Acute renal injury induced by ischemia is a major cause of high morbidity and mortality in hospitalized patients and a common complication in hospitalized patients. Thus, the work with acute renal failure and renal ischemia has been studied for many years. Although serum creatinine concentration that is widely used as an index of renal function performs fairly well for estimating kidney function in patients with stable chronic kidney disease, it performs poorly in the setting of acute disease. Thus, an ideal biomarker for acute kidney injury would help clinicians and scientists diagnose the most common form of acute kidney injury in hospitalized patients, acute tubular necrosis, early and accurately, and may aid to risk-stratify patients with acute kidney injury by predicting the need for renal replacement therapy, the duration of acute kidney injury, the length of stay and mortality. In this study, renal ischemia and reperfusion were performed by clapming and un-clamping right renal artery in miniature pigs. Plasma blood urea nitrogen (BUN) and creatinine were examined at pre- clamping, after-clamping at 0, 1 and 3 hours. And we searched initial indicators in these samples. Also, renal tissue was collected and searched the initial indicator by PCR and western blotting. As a result, hypoxia inducible factor $1{\alpha}$ ($HIF1{\alpha}$), nuclear factor kappa-B ($NF{\kappa}B$), $I{\kappa}B$, erythropoietin (EPO), erythropoietin receptor (EPOR), angiopoietin-1 and vascular endothelial growth factor (VEGF) were showed significant changes among the renal protein. $HIF1{\alpha}$, EPO, and EPOR were showed significant changes among the renal gene. Thus, these markers will be used as initial diagnosis of acute renal failure.

Isolating Vibration in Miniature Linear Cryogenic Cooler with Tuned Vibration Absorber (동조질량 진동흡수기를 이용한 미니 저온쿨러의 진동 절연)

  • Kim, Young-Keun;Kim, Hong-Bae;Kim, Eung-Hyun;Kim, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.605-609
    • /
    • 2010
  • In modern surveillance equipment, infrared (IR) sensors are essential for detection and observation. The IR sensor is connected to a miniature cryogenic cooler to maintain the temperature at very low levels, i.e., temperatures as low as 77 K. However, the quality of the image captured by the sensor is degraded by the transmission of vibration disturbances from the cooler. Therefore, to maintain high image quality, the compressor vibration and the force transmitted to the sensor have to be mitigated. For the compressor vibration isolating system, a tuned dynamic vibration absorber, combined with a passive isolator, is proposed. A cryogenic compressor bracket and springs are designed to allow the absorber mass to mitigate the vibration jitter in the axial direction. The system design is analyzed and evaluated in terms of the dynamic suppression of the harmonic force at the operating frequency of the cooler.

Initial Excess Pore Pressure Induced by Cone Penetration in Normally Consolidated Clays (정규압밀점토에서의 피에조 콘 관입에 의한 과잉간극수압에 대한 연구)

  • 임형덕;이우진;김대규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.151-161
    • /
    • 2003
  • In this study, an interpretation method is proposed to evaluate the stress conditions, including individual excess pore pressure components ($\Delta{u}_{oct}$/ and $\Delta{u}_{shear}$), of normally consolidated clay elements adjacent to the cone face. It is assumed that the stress path of triaxial compression is representative f3r that of the soil element and the soil is elastic-perfectly plastic material. The proposed method is applied to the results of miniature piezocone tests conducted at Louisiana State University calibration chamber system. Based on the results of interpretation, it was found that the ratio of $\Delta{u}_{oct}$/ $\Delta{u}$and $\Delta{u}_{shear}$/$\Delta{u}$ estimated by the proposed method is affected only by the pore pressure parameter. The proposed method gives consistent and reliable values of $\Delta{u}_{oct}$/ $\Delta{u}$and $\Delta{u}_{shear}$/$\Delta{u}$ compared with early works, whereas those obtained by other solutions are significantly dependent on the accuracy in estimating soil properties such as undrained shear strength and rigidity index.

A Study on Redesign and Utilization of a Convective Circulation Box for Observations of Land and Sea Breezes (해륙풍 원리 이해를 위한 대류상자 재설계와 활용에 관한 연구)

  • Yang, Mi-Seon;Yun, Sung-Hyo
    • Journal of the Korean earth science society
    • /
    • v.31 no.3
    • /
    • pp.246-258
    • /
    • 2010
  • A convective circulation box was redesigned after analyzing reasons why adolescent elementary school students could not derive a convective circulation concept from the convection circulation box experiments. Even though students were in the formal operational period of Piaget, the adolescents felt difficult to understand a concept of the natural phenomena they have never seen before. Thus, we designed a method to help students increase their scientific understandings about the concept through developing a miniature convective circulation box. Findings indicated that an application of redesigned convective circulation box in the classroom experiment significantly increased the students' understanding about the convective circulations of land and sea breezes, and as well as their participation in the activities. In addition, the redesigned convective circulation box motivated students to develop their scientific thinking skills by allowing them to decide where to put visible incenses inside the box and to directly observe the smoke currents circulation formed accordingly. Redesigning and using a convective circulationbox as a miniature of natural phenomenon helps students avoid having misconceptions. The biggest merits of the box are that it is observable in all directions, it provides much clearer convective circulations comparing to the extant box, and it requires low production costs.

Application of Miniature Heat Pipe for Notebook PC Cooling (노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구)

  • Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.

Modeling of Two-axis Miniature Fine Sun Sensor for Accuracy Improvement (정밀도 향상을 위한 2축 소형 정밀 태양센서의 모델링)

  • 윤미연;최정원;장영근;이병훈
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.7
    • /
    • pp.71-78
    • /
    • 2006
  • Sun sensors are frequently implemented by satellites for attitude sensing, due to its simple manufacturability and light weight. A modeling of sun sensors has an important effect on the accuracy of satellite attitude determination. This paper addresses a new modeling of a 2-axis miniature fine sun sensor with improved accuracy. Unlike other previous algebraic modeling methods, the newly suggested physical modeling method takes into account the shadowing effect of the slit thickness. It was shown that a newly proposed sun sensor modeling provides a substantial accuracy improvement of 29% compared to the generic algebraic modeling. The proposed sensor modeling was validated using 2-axis fine sun sensors with FOV(Field of View) of ${\pm}60^{\circ}$ mounted on HAUSAT-2 small satellite, currently under development by SSRL(Space System Research Lab.) at Hankuk Aviation University, Korea.

Comparison of the Growth of Hydrophytes, Aquatic Biota and Absorption of Nutrient depending on the Planting Mat Type of Artificial Vegetation Island (인공수초재배섬 식생기반재 종류에 따른 물질 흡착량 및 생물상, 식재식물 성장 비교)

  • Choi, Myung-Jae;Park, Hae-Kyung;Byeon, Myeong-Seop;Jeon, Nam-Hui;Yun, Seok-Hwan
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.52-60
    • /
    • 2010
  • We investigated temporal changes of growth of hydrophytes, aquatic biota and absorption of nutrient depending on planting mat type (synthetic fiber, coconut fiber) of artificial vegetation island (AVI) through pilot test using AVI miniatures in Kyungan Stream area of Lake Paldang. There were not significant differences of the water quality parameters (DO, pH, conductivity, turbidity, temperature), phytoplankton and zooplankton abundance among AVI miniatures and control station. The benthic macroinvertebrates showed most individual numbers in the miniature which was made by synthetic fiber and planted with Phragmites australis. The average and maximum height of hydrophytes in AVI miniatures was similar except one miniature where Phragmites australis was planted in synthetic fiber mat and grew more slowly. The adsorbed amount of nutrients and microbes in coconut fiber mat were larger than those in synthetic fiber mat regardless of trophic state of installed waterbody. The continuous increase of adsorbed amount of nutrients and microbes of coconut fiber mat for 8 months in an oligotrophic lake indicates that coconut fiber mat is suitable for the planting mat of AVI in an oligotrophic lake where nutrients are limited for growth of hydrophytes.