• Title/Summary/Keyword: microfluidic

Search Result 427, Processing Time 0.028 seconds

Soft lithographic patterning of proteins and cells inside a microfluidic channel (소프트 리소그라피를 이용한 마이크로유체 채널 내의 단백질 및 세포 패터닝)

  • Suh, Kahp-Yang
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • The control of surface properties and spatial presentation of functional molecules within a microfluidic channel is important for the development of diagnostic assays, microreactors, and for performing fundamental studies of cell biology and fluid mechanics. Here, we present soft lithographic methods to create robust microchannels with patterned microstructures inside the channel. The patterned regions were protected from oxygen plasma by controlling the dimensions of the poly(dimethylsiloxane)(PDMS) mold as well as the sequence of fabrication steps. The approach was used to pattern a non-biofouling polyethylene glycol(PEG)-based copolymer or the polysaccharide hyaluronic acid(HA) within microfluidic channels. These non-biofouling patterns were then used to fabricate arrays of fibronectin(FN) and bovine serum albumin(BSA) as well as mammalian cells.

Application of CFD-VOF Model to Autonomous Microfluidic Capillary System (마이크로 모세관 유동 해석을 위한 CFD-VOF 모텔 응용)

  • Jeong J.H.;Im Y.H.;Han S.P.;Suk J.W.;Kim Y.D.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.224-229
    • /
    • 2004
  • The objective of this work is not only to perform feasibility studies on the CFD (computational fluid dynamics) analysis for the capillary system design but also to provide an enhanced understanding of the autonomous capillary flow. The capillary flow is evaluated by means of the commercial CFD software of FLUENT, which includes the VOF (volume-of-fluid) model for multiphase flow analysis. The effect of wall adhesion at fluid interfaces in contact with rigid boundaries is considered in terms of static contact angle. Feasibility studies are first performed, including mesh-resolution influence on pressure profile, which has a sudden increase at the liquid/gas interface. Then we perform both 2D and 3D simulations and examine the transient nature of the capillary flow. Analytical solutions are also derived for simple cases and compared with numerical results. Through this work, essential information on the capillary system design is brought out. Our efforts and initial success in numerical description of the microfluidic capillary flows enhance the fundamental understanding of the autonomous capillary flow and will eventually pave the road for full-scale, computer-aided design of microfluidic networks.

  • PDF

Optical Detection of Red Blood Cell Aggregation in a Disposable Microfluidic Channel

  • Shin Sehyun;Jang Ju-Hee;Park Myung-Soo;Ku Yunhee;Suh Jang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.887-893
    • /
    • 2005
  • The aggregability of red blood cells (RBCs) was determined by laser backscattering light analysis in a microfluidic channel. Available techniques for RBC aggregation often adopt a rotational Couette-flow using a bob-and-cup system for disaggregating RBCs, which causes the system to be complex and expensive. A disposable microfluidic channel and vibration generating mechanism were used in the proposed new detection system for RBC aggregation. Prior to measurement, RBC aggregates in a blood sample were completely disaggregated by the application of vibration-induced shear. With the present apparatus, the aggregation indexes of RBCs can be measured easily with small quantities of a blood sample. The measurements with the present aggregometer were compared with those of LORCA and the results showed a strong correlation between them. The aggregability of the defibrinogenated blood RBCs is markedly lower than that of the normal RBCs. The noble feature of this design is the vibration-induced disaggregation mechanism, which can incorporate the disposable element that holds the blood sample.

Microfluidic LOC System (Microfluidic LOC 시스템)

  • Kim, Hyun-Ki;Gu, Hong-Mo;Lee, Yang-Du;Lee, Sang-Yeol;Yoon, Young-Soo;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.906-911
    • /
    • 2004
  • In this paper, we used only PR as etching mask, while it used usually Cr/AU as etching mask, and in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. we designed microchannel size width max 10um, min 5um depth max 10um, reservoir size max 100um, min 2mm. Fabrication of microfluidic devices in glass substrate by glass wet etching methods and glass to glass fusion bonding. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive($4k{\Omega}{\cdot}cm$) wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571\Omega$ to $393\Omega$.

  • PDF

Optical Manipulation of Droplets in a Microfluidic Platform (미세 유체 플랫폼에서의 광력을 이용한 액적의 연속적인 제어 기술의 개발)

  • Jung, Jin Ho;Cho, Hyunjun;Ha, Byung Hang;Destgeer, Ghulam;Sung, Hyung Jin
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.13-17
    • /
    • 2014
  • In the present study, the optofluidic droplet manipulation in a microfluidic platform was demonstrated via theoretical and experimental approaches. Optical scattering force and gradient force were used to separate and trap droplets. Two types of droplets were generated by a T-junction method in the microfluidic channel. While they approach a test region where the optical beam illuminates the droplets, they were pushed by the optical scattering beam. The displacement by the laser beam is dependent on the refractive index of the droplets. By using the optical gradient force, the droplets can be trapped and coalesced. In order to bring the droplets in a direct contact, the optical gradient force was used to trap the droplets. A theoretical modeling of the coalescence was derived by combining the optical force and drag force on the droplet.

New Materials Based Lab-on-a-Chip Microreactors: New Device for Chemical Process

  • Kim, Dong-Pyo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.51-51
    • /
    • 2012
  • There is a growing interest in innovative chemical synthesis in microreactors owing to high efficiency, selectivity, and yield. In microfluidic systems, the low-volume spatial and temporal control of reactants and products offers a novel method for chemical manipulation and product generation. Glass, silicon, poly(dimethylsiloxane) (PDMS), and plastics have been used for the fabrication of miniaturized devices. However, these materials are not the best due to either of low chemical durability or expensive fabrication costs. In our group, we have recently addressed the demand for economical resistant materials that can be used for easy fabrication of microfluidic systems with reliable durability. We have suggested the use of various specialty polymers such as silicon-based inorganic polymers and fluoropolymer, flexible polyimide (PI) films that have not been used for microfluidic devices, although they have been used for other areas. And inexpensive lithography techniques were used to fabricate Lab-on-a-Chip type of microreactors with differently devised microchannel design. These microreactors were demonstrated for various synthetic reactions: liquid, liquid-gas organic chemical reactions in heterogeneous catalytic processes, syntheses of polymer and non-trivial inorganic materials. The microreactors were inert, and withstand even harsh conditions, including hydrothermal reaction. In addition, various built-in microstructures inside the microchannels, for example Pd decorated peptide nanowires, definitely enhance the uniqueness and performance of microreactors. These user-friendly Lab-on-a-Chip devices are useful alternatives for chemist and chemical engineer to conventional chemical tools such as glass.

  • PDF

Continuous Production of Immunoliposomes using a Microvalve-controlled Microfluidic Device (μFD)

  • Jin, Yan;Kim, So Hyun;Kim, Myunghee;Park, Sungsu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2921-2924
    • /
    • 2013
  • Immunoliposomes (antibody-conjugated liposomes) are highly useful as both a drug carrier in drug delivery and as a reporting probe in immunodiagnostics. However, antibody conjugation is lengthy and cumbersome, because this includes several steps such as derivatization of the antibody, conjugation of the derivatized antibody to liposomes, and separation of the unbound antibodies from immunoliposomes. Recently, liposome preparation steps have simplified by using microfluidic devices (${\mu}FDs$) where liposomes are formed when a stream of lipids in solvent is hydrodynamically focused between two oblique buffer streams in a microchannel. Herein, we report a simple method for the production of immunoliposomes (rabbit IgG-conjugated liposomes) using microvalve-controlled ${\mu}FD$. The presence of antibody on the liposome was verified by observing the binding of immunoliposomes to rabbit IgG on the surface. The results suggest that immunoliposomes can be easily prepared through sequential mixing of antibody, conjugation reagents, preformed liposomes using microvalve-controlled ${\mu}FD$.

On-Chip Fabrication of PDA Sensor Fiber Using Laser Polymerization and 3-D Hydrodynamic Focusing (3-D 유체집속효과와 레이저 중합반응을 이용한 PDA 센서 미세섬유 제작)

  • Yoo, Im-Sung;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2692-2695
    • /
    • 2008
  • Polydiacetylene (PDA) is chemosensor materials that exhibit non-fluorescent-to-fluorescent transition as well as blue-to-red visible color change upon chemical or thermal stress. They have been studied in forms of film or microarray chip, so far. In this paper, we provide a novel technique to fabricate continuous micro-fiber PDA sensor using in-situ laser-polymerization technique and 3-D hydrodynamic focusing on a microfluidic chip. The flow of a monomer solution with diacetylene (DA) monomer is focused by a sheath flow on a 3-D microfluidic chip. The focused flow is exposed to 365 nm UV laser beam for in-situ polymerization which generates a continuous fiber containing DA monomers. Then, the fiber is exposed to 254 nm UV light to polymerize DA monomers to PDA. Preliminary results indicate that the fiber size can be controlled by the flow rates of the monomer solution and sheath flows and that a PDA sensor fiber successively responds to chemical and thermal stress.

  • PDF

Electrokinetic flow and electroviscous effect in a charged slit-like microfluidic channel with nonlinear Poisson-Boltzmann field

  • Chun, Myung-Suk;Kwak, Hyun-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.2
    • /
    • pp.83-90
    • /
    • 2003
  • In cases of the microfluidic channel, the electrokinetic influence on the transport behavior can be found. The externally applied body force originated from the electrostatic interaction between the nonlinear Poisson-Boltzmann field and the flow-induced electrical field is applied in the equation of motion. The electrostatic potential profile is computed a priori by applying the finite difference scheme, and an analytical solution to the Navier-Stokes equation of motion for slit-like microchannel is obtained via the Green's function. An explicit analytical expression for the induced electrokinetic potential is derived as functions of relevant physicochemical parameters. The effects of the electric double layer, the zeta potential of the solid surface, and the charge condition of the channel wall on the velocity profile as well as the electroviscous behavior are examined. With increases in either electric double layer or zeta potential, the average fluid velocity in the channel of same charge is entirely reduced, whereas the electroviscous effect becomes stronger. We observed an opposite behavior in the channel of opposite charge, where the attractive electrostatic interactions are presented.

Brief Review on the Processes for RNA-Platform Vaccine Production (RNA 플랫폼 백신 제조공정 고찰 연구)

  • Roh, Hyungmin;Oh, Kyeongseok
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.179-186
    • /
    • 2021
  • Among the Covid-19 vaccine platforms, mRNA-platform vaccines are summarized qualitatively in this paper. Manufacturing mRNA vaccines consist of serial processes; the preparation process of DNA template, the transcription of mRNA, nanoemulsion process, and the fill and finish unit combined with formulation stages. It is noticeable that major players are collaborated for producing mRNA vaccines. In particular, the nanoemulsion process is recognized to the key process requiring formulated lipid materials to protect modified mRNA until they arrive in intracellular cytosol. It is known that the nanoemulsion process adapts well-designed microfluidic devices. We expect that the nanoemulsion process will stimulate pharmaceutical industries to develop diverse applications.