• Title/Summary/Keyword: microbalance

Search Result 187, Processing Time 0.024 seconds

Response Characteristics of Organic Gas for Polymer Coating Materials (고분자 감응성막의 유기가스 반응 특성)

  • 김정명;유승엽;장정수;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.273-276
    • /
    • 1995
  • In this paper, the response characteristics of organic gases were investigated by using quartz crystal microbalance(Q.C.M) with different coating materials. The method for pattern was discussed in order to develope gas sensing system using neural network and pattern recognition. we analyzed the response characteristics by the area of frequency shift, which mean affinities of gases for coating material. The results shows that the Parameter made by the area of frequency shift has possibility to be used for pattern recognition and neural network. we found that each gas had different decrease pattern for coating material.

  • PDF

액체/초임계 이산화탄소의 QCM을 이용한 초음파 세척 효과 연구

  • 박광헌;고문성;윤청현;김홍두;김학원
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.2-2
    • /
    • 2002
  • Quartz Crystal Microbalance(QCM)은 표면에 묻은 물질의 미량의 무게변화도 간단히 측정 할 수 있어 반웅기 내에서 일어나는 현상올 in-situ로 즉시 알 수 있는 장점을 가진 장치이 다. 이 장치를 이용하면 초엄계 이산화탄소 내에서 용해도를 알 수 있고, 대상물질이 녹아냐 가는 속도를 측정하면 확산계수를 구할 수 있다. 그리고, 초음파 혼을 반응용기 내에 설치하 고, 초음파 효과를 알아보았다. 먼저 static system에서 초음파 효과를 알아보았다. Cu(acac)2를 대상으로, 밀폐된 용기에서 수행한 실험에서, 액체와 초임계 이산화탄소 내에서 용해속도를 QCM으로 구할 수 있었다. 용해속도로부터 Cu(acac)2의 확산계수를 측정할 수 있었다. 액체 내에선 $10^{-4}{\;}cm2/sec$, 초임계상태에서 $10^{-2}{\;}cm2/sec$의 값을 갖는 것으로 나타 났다. 그리고, 초음파를 사용할 경우 이 확산계수값이 4-5배정도 증가하는 것으로 냐타났다. 이어서 dynamic system에서 반응을 알아보았다. Cyanex를 함유한 C02를 반응용기에 흘리 면서 QCM표면에 묻은 Co이온의 용해속도를 측정하였다. 초음파는 용해도에 아무 역활을 안하는 것으로 나타났다. 주어진 조건에서 13 microgram/gram-cyanex의 용해도를 갖는 것 으로 나타났다.

  • PDF

Hydrogen Absorption and Electronic Property Change of Yttrium Thin Films

  • Cho, Young-Sin
    • Journal of Hydrogen and New Energy
    • /
    • v.7 no.1
    • /
    • pp.71-79
    • /
    • 1996
  • Yttrium thin film, 580nm thick, was prepared by electron beam evaporation. Film was hydrogenated room temperature upto 40 bar hydrogen pressure, without any activation process. Hydrogen concentration was determined by a quartz-crystal microbalance(QCM) method. YH2.9 sample was made without any pulverization. Electrical resistance was measured by four-point DC method in the temperature range between room temperature and 30K for various hydrogen concentration, x=0 to 2.9 of YHx sample. Temperature dependent resistance of YH2.9 shows low temperature minimum at 105K, the metal-semiconductor transition at 260K, and a hystersis above 210K.

  • PDF

대장균 검출을 위한 항체고정화 Quartz Crystal Microbalance 시스템의 특성

  • Park, In-Seon;Kim, Nam-Su
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.701-702
    • /
    • 2000
  • The thiolated anti-Escherichia coli antibody prepared by thiolation with a thiolcleavable heterobifunctional cross-linker, sulfosuccinimidyl 6[3- (2-pyridyldithio) propionamido]hexanoate (sulfo-LC-SPDP) was chemisorped onto one gold electrode of the piezoelectric quartz crystal surface. In the QCM system employing a batch-type well holder, a steady-state frequency decrease was attained within 20 min when $100{\sim}200\;{\mu}L$ suspensions of Escherichia coli having viable cell counts of $10^5{\sim}10^6\;CFU/mL$ were added. The stability of sensor response was improved compared to the system with a batch-type dip holder.

  • PDF

The Relationships between the Porosity of Activated Carbon and Hydrogen Adsorption Capacity (활성탄의 기공도와 수소홀착능 사이의 관계)

  • JIN, Hangkyo
    • Journal of Hydrogen and New Energy
    • /
    • v.14 no.4
    • /
    • pp.305-312
    • /
    • 2003
  • A study is presented of the adsorption capacity of a number of different activated carbons for hydrogen at 100 bar aad 298 K. The hydrogen adsorption isotherm was measured by isothermal gravimetric analysis, using a microbalance. The effect of activated carbon's porosity on hydrogen adsorption capacity is surveyed. It is concluded that hydrogen adsorption capacity of activated carbon is lineally increased according to the increase of specific surface area and total pore volume, It seems that microporosity is more contributive than mesoporosity. Most of the adsorbed quantity is due to physical adsorption and chemisorption is negligible, In this work, 0.79 wt.% of hydrogen adsorption capacity is reached.

Gas Response Properties of Q.C.M. for Various Temperature (온도 변화에 대한 Q.C.M.의 가스 반응 특성)

  • Jin, Chel-Nam;Kim, Kyung-Hwan;Kang, Hyen-Wook;Yoo, Seung-Yeop;Park, Jae-Chul;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1503-1505
    • /
    • 1998
  • Stearic acid was deposited on surface of 9[MHz], AT-cut quartz crystal microbalance as gas sensing material using Langmuir-Blodgett(LB) technique. We measured gas response between deposited LB films and organic gas for various temperature($0{\sim}80^{\circ}C$). The resonant frequency changed due to absorbance of organic gas such as methanol and butanol gas at room temperature. However, the resonant frequency not responded to methanol gas at temperature above melting point of deposited LB films.

  • PDF

Suppression of silicon clusters using a grid mesh under DC bias

  • Kim, Yonwon;Kang, Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.146-149
    • /
    • 2017
  • Si clusters generated during the plasma chemical vapor deposition (CVD) process have a great influence on the quality of the fabricated films. In particular, in hydrogenated amorphous silicon thin films (a-Si:H) used for thin film solar cells, Si clusters are mainly responsible for light-induced degradation. In this study, we investigated the amount of clusters incorporated into thin films using a quartz crystal microbalance (QCM) and specially designed cluster eliminating filters, and investigated the effect of the DC grid mesh in preventing cluster incorporation. Experimental results showed that as the applied voltage of the grid mesh, which is placed between the electrode and the QCM, decreased, the number of clusters incorporated into the film decreased. This is due to the electrostatic force from the grid mesh bias, and this method is expected to contribute to the fabrication of high-quality thin films by preventing Si cluster incorporation.

A study on the $NO_2$ Gas Detection Characteristics of Octa(2-ethylhexyloxy)copper-phthalocyanine LB Films (Octa(2-ethylhexyloxy)copper-phthalocyanine LB막의 $NO_2$ 가스 탐지 특성에 관한연구)

  • Yim, Jun-Seok;Kim, Young-Kwan;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1716-1718
    • /
    • 1996
  • It is well known that the metallophthalocyanine (MPcs) are sensitive to toxic gaseous molecules such as $NO_2$ and also chemically and thermally stable. Therefore, lots of MPcs are studied for the potential chemical sensor for $NO_2$ gas using quartz crystal microbalance(QCM) or electrical conductivity. In this study, thin films of octa(2-ethylhexyloxy) copper-phthalocyanine were prepared by Langmuir-Blodgett method and characterized by using UV-VIS spectrascopy and ellipsometry. Transfer condition, film characterization, and preliminary results of current-voltage(I-V) characteristics of these films exposed to $NO_2$ gas as a function of film thickness will be discussed.

  • PDF

Study on Electrochemical Property of Self-Assembled Viologen Monolayers Using Electrochemical Quartz Crystal Microbalance (EQCM) Method (EQCM법을 이용한 자기조립된 Viologen 단분자막의 전기화학적 특성 연구)

  • Lee, Dong-Yun;Park, Sang-Hyun;Park, Jae-Chul;Kwon, Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.107-110
    • /
    • 2006
  • We fabricated the monolayers onto QCM by self-assembly using viologen, which has been widely used as electron acceptor. A gold electrode of the QCM was cleaned by piranha solution and prepared the ethanol-acetonitrile(1:1) solution with 2 m mol/l viololgen compounding of pure hi gas. We determined the time dependence to resonant frequency shift during self-assembly process and the electrochemical behavior of the self-assembled viologen monolayers by cyclic voltammetry. With increasing scan rate, the redox peak current of the viologen increased linearly. This was signified that the redox reaction was reversible. The EQCM measurements revealed the anions transfer during redox reactions, respectively. From the EQCM data, the well-defined shape peaks were nearly equal charges by cyclic voltammetry.

The Rheological Characteristics of Polymer Sensitive Materials for Organic Gas (유기가스에 대한 고분자 감응성막의 유변학적인 특성)

  • 김정명;김용성;장정수;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.31-34
    • /
    • 1996
  • In this paper, the rheological chances in sensitive materials was investigated by using QCA(Quartz Chemical Analyzer). Langmuir-Blodgett method was used to transfer sensitive material to the quartz crystals because of its facility to control that amount, and deposited sensitive material has uniformity to compare with other methods respectively. For the gas sensor using mass loading effect of quartz crystal microbalance, generally the Sauberary equation has been believed to represent the only mass loading effect. But when the organic gas is adsorpted into sensitive material, the rheological changes are occurred with different pattern as to the kinds of gases. Thus, much simpler method to identify the organic or hazard gas will be obtained by the consideration of resonant frequency changes and resonant admittance changes simultaneously.

  • PDF