• Title/Summary/Keyword: micro-morphology

Search Result 363, Processing Time 0.027 seconds

New Retention System Using Branched Polymer

  • Son, Dong-Jin;Kim, Bong-Yong
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.251-256
    • /
    • 2006
  • The purpose of this study was to confirm multiple retention system of C-PAM, A-PAM and Inorganic micro particles vs. traditional micro particle system and dual polymer system by measuring retention, drainage and formation using RDA HSF and Techpap 2D -F Sensor The benefits of dual polymer system were easy to use, low chemical consumption and good retention property but defect was worse drainage property than inorganic microparticle systems. On the other hand, Inorganic microparticle system had benefit of good drainage effect but defects were difficult to use, high chemical consumption. Therefore, we tried to find optimal morphology of polyacrylamide and applied to multiple retention system of C-PAM, A-PAM and inorganic microparticles to compensate defects of both of retention systems. As a result, we found the performance of branched C-PAM, branched A-PAM and inorganic micro particle triple system was more appropriate than traditional inorganic mircoparticle systems or dual polymer systems by comparing retention, drainage and formation.

  • PDF

3D Surface Model Generation of Micro Structure by Self Calibration of The SEM Image (SEM 영상의 자체검정에 의한 미세구조물의 3차원 표면모델 생성)

  • 이효성;박형동
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.151-159
    • /
    • 2003
  • This study presents method for self-calibration of the SEM(Scanning Electron Microscope) stereo image using the standard microprobe with same grid pattern and using parallel and central perspective projection equation. Result showed that parallel projection method is more suitable for standard microprobe. The maximum error of 3D coordinates acquired by this method did not exceed 5 $\mu\textrm{m}$, and DSM(Digital Surface Model) for three dimensional measurement of the rock sample was generated by the digital photogrammetry. This result can be used for quantification of micro scale change of shape and analysis of the micro morphology of rock due to weathering.

  • PDF

An Study on the Change of the critical J-value and the Fracture Morphology of the Vibration - Proof Natural Rubber due to Carbon Black (방진부품용 천연고무의 카본블랙에 의한 임계J값과 파단 모폴로지 변화에 관한 연구)

  • 김재훈;정현용;구병춘
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.72-79
    • /
    • 2002
  • The effects of carbon black on the critical J-value and the surface fracture morpology of the carbon-black filled natural rubbers were investigated. Different kinds of carbon blacks resulted in different critical J-values, surface, and roughness. It was noticed that the critical J-value was almost the same regardless of the length of a pre-crack. In addition, different kinds of carbon blacks resulted in different fracture morphologies, and micro-scale and macro-scale roughnesses. The critical J-value could be linearly expressed by the micro-scale roughness and the macro-scale roughness and it seemed related to the size distribution of carbon black particles. And we also found that the macro-scale ms roughness was more sensitive than the micro-scale ms roughness to the critical J-value by the result of correlation coefficient, r$^2$.

  • PDF

Surface Morphological Properties of Micro-arc Oxidation Coating on Al6061 Alloys using Unipolar Pulse (Unipolar pulse를 이용하여 형성된 Al6061 합금 표면의 MAO 코팅의 표면 구조에 대한 연구)

  • Kim, Nam-youl;Park, Seung-Ho;Park, Ki-Youg;Choi, Jin-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.421-426
    • /
    • 2017
  • Herein, we investigated surface morphological characteristics of anodic films on Al6061 alloy prepared by unipolar pulsed Micro-arc oxidation (MAO) in a mixed solution of $Na_2SiO_3$ + KOH. The number and size of pores as well as craters on anodic alumina surface were studied as a function of different voltages, duty cycles and applied anodic current densities. The morphological characteristics of all samples were investigated by scanning electron microscopy, conforming that the most uniform surface morphology of MAO films on Al1050 alloy was obtained at high applied current density with low duty cycle.

In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review

  • Chang, Seok-Woo;Lee, Jong-Ki;Lee, Yoon;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.2-10
    • /
    • 2013
  • A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB) canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.

A Study on the Friction and Wear Characteristics of Nitrogen Ions Coated SCM415 Steel (질소이온 코팅 SCM415강의 마찰.마모특성에 관한 연구)

  • Lyu, Sung-Ki;He, Hei-bo;Son, Yu-Sun
    • Tribology and Lubricants
    • /
    • v.23 no.1
    • /
    • pp.14-18
    • /
    • 2007
  • SCM415 alloy was implanted with nitrogen ions using plasma source ion implantation (PSII), at a dose range of $1{\times}10^{17}\;to\;6{\times}10^{17}N^{+}cm^{-2}$. Auger electron spectrometry (AES) was used to investigate the depth profile of the implanted layer. Friction and wear tests were carried out on a block-on-ring wear tester. Scanning electron microscopy (SEM) was used to observe the micro-morphology of the worn surface. The results revealed that after being implanted with nitrogen ions, the frictional coefficient of the surface layer decreased, and the wear resistance increased with the nitrogen dose. The tribological mechanism was mainly adhesive, and the adhesive wear tended to become weaker oxidative wear with the increase in the nitrogen dose. The effects were mainly attributed to the formation of a hard nitride precipitate and a supersaturated solid solution of nitrogen in the surface layer.

A study on the uniformity of the electrodeposits in Pb-Sn-Cu ternary alloy plating (Pb-Sn-Cu삼원 합금 전착층의 균일성 연구)

  • NamGoong, E.;Gwon, Sik-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.18 no.3
    • /
    • pp.105-115
    • /
    • 1985
  • Lead-tin-copper ternary alloy electrodeposition is conducted onto the inner bore surface of plain bearings as an overlay in order to investigate the effect of slot width, current density and fluoboric acid concentration on the uniformity of overlay. The thickness of overlay is analyzed by means of current distribution resulting from the overvoltage of plating bath and the apparent distance between cathode and anode. The result demonstrate that the uniformity of overlay is remarkably dependent of the slot size and current density, but has little bearing on the fluoboric acid concentration over 100g/L. This present study indicates that uniform overlay is obtainable within the tolerable thickness of ${\pm}2{\mu}m$ by using the slot width of 22mm. The surface morphology examination also shows the important role of concentration polarization of the micro-uniformity of overlay. The micro-uniformity has improved at the low concentration polarization which resulted from operating at the low current density and high fluoboric acid concentration. The surface morphology of deposits exhibits the vivid pyramid crystalline in the plating condition of low concentration polarizatio and all deposits have columnar structure parallel to the applied electric field regardless of the electroplating condition used.

  • PDF

Detecting and Tracking Changes of Mechanical Characteristics in the Trabecular and Cortical Bone of the Lumbar Vertebrae for an Ovariectomised Rat using In-Vivo Micro-CT and Micro Finite Element Analysis (IN-VIVO MICRO-CT 와 미세 유한요소법를 이용한 쥐의 골다공증 해면골과 피질골의 구조적 특성 추적관찰 및 기계적 특성 분석)

  • Ko C.Y.;Woo D.G.;Kim H.S.;Lee B.L.;Tack G.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.892-895
    • /
    • 2005
  • This study investigated changes of mechanical characteristics in the trabecular and cortical bone of the lumbar vertebrae of the ovariectomised(OVX) rat. In previous researches, there were many studies for morphology of osteoporotic bones based on Micro-CT (Micro - Computed Tomography). However, there were few studies for detecting and tracking changes of mechanical characteristics in the trabecular bone and cortical bone of the lumbar vertebrae for the OVX rat. For this study, one female Sprague-Dawley rat was used: an OVX rat. The 4th lumbar of the OVX rat was utilized as a specimen. Detecting and tracking changes of mechanical characteristics could be investigated in the trabecular and cortical bone of the lumbar vertebrae for an OVX rat using In-vivo Micro-CT. An OVX rat was scanned at week 0 (just before surgery), at week 4, and week 8 after surgery. Micro finite element(${\mu}\;FE$) analysis was used to investigate mechanical characteristics in the trabecular and cortical bone of the lumbar vertebrae for an OVX rat.

  • PDF

Finite Element Simulation and Experimental Study on the Electrochemical Etching Process for Fabrication of Micro Metal Mold (미세금형 가공을 위한 전기화학식각 공정의 유한요소 해석 및 실험결과 비교)

  • Ryu, Heon-Yul;Im, Hyeon-Seung;Cho, Si-Hyeong;Hwang, Byeong-Jun;Lee, Sung-Ho;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.22 no.9
    • /
    • pp.482-488
    • /
    • 2012
  • To fabricate a precise micro metal mold, the electrochemical etching process has been researched. We investigated the electrochemical etching process numerically and experimentally to determine the etching tendency of the process, focusing on the current density, which is a major parameter of the process. The finite element method, a kind of numerical analysis, was used to determine the current density distribution on the workpiece. Stainless steel(SS304) substrate with various sized square and circular array patterns as an anode and copper(Cu) plate as a cathode were used for the electrochemical experiments. A mixture of $H_2SO_4$, $H_3PO_4$, and DIW was used as an electrolyte. In this paper, comparison of the results from the experiment and the numerical simulation is presented, including the current density distribution and line profile from the simulation, and the etching profile and surface morphology from the experiment. Etching profile and surface morphology were characterized using a 3D-profiler and FE-SEM measurement. From a comparison of the data, it was confirmed that the current density distribution and the line profile of the simulation were similar to the surface morphology and the etching profile of the experiment, respectively. The current density is more concentrated at the vertex of the square pattern and circumference of the circular pattern. And, the depth of the etched area is proportional to the current density.

Detecting and Tracking Changes of Mechanical Characteristics of the Trabecular and Cortical Bone in the Lumbar Vertebrae of an OVX Rat - Use of In-Vivo Micro-CT and Micro-FE Analysis - (난소 절제술을 시행한 흰쥐 등뼈의 해면골과 피질골의 구조적 특성 추적관찰 및 기계적 특성 분석 - 생체 내 미세단층촬영 시스템과 미세 유한요소법 적용 -)

  • Ko, Chang-Yong;Woo, Dae-Gon;Lee, Tae-Woo;Lee, Beob-Yi;Tack, Gye-Rae;Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.110-117
    • /
    • 2007
  • This study investigated changes of mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae of the ovariectomised (OVX) rat. In previous researches, there were many studies for morphology of osteoporotic bones based on Micro-Computed Tomography (Micro-CT). However, there were few studies for detecting and tracking changes of mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae of the OVX rat. For this study, the 4th lumbar of the OVX rat (female Sprague-Dawley) was utilized as a specimen. An OVX rat was scanned at week 0 (just before surgery), at week 4, and week 8 after surgery. Micro-finite element (${\mu}-FE$) analysis was used to investigate mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae for an OVX rat. When the OVX rat (at week 8) was compared with the OVX rat (at week 0), the structural modulus of cortical and trabecualr bone was decreased by 52% and 99%, respectively. This study showed the change of mechanical characteristics of cortical bone as well as trabecular bone of an OVX rat. Detecting and tracking changes of mechanical characteristics could greatly contribute to an experiment test for the trabecular and cortical bone in the lumbar vertebrae of an OVX rat by using In-vivo Micro-CT.