• 제목/요약/키워드: micro-channel Flow

검색결과 221건 처리시간 0.025초

나노 파운틴펜의 동적해석에 관한 연구 (A Study on Dynamic Analysis of Nano Fountain Pen)

  • 이영관;김훈모;김윤제;이석한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.922-929
    • /
    • 2006
  • In this study, flow characteristics of the FPN (Fountain Pen Nano-Lithography) using active membrane pumping are investigated. This FPN has integrated chamber, micro channel, and high capacity reservoir for continuous ink feed. The most important aspect in this probe provided control of fluid injection using active membrane pumping in chamber. The flow rates in channel by capillary force are theoretically analyzed, including the control of mass flow rates by deflection of membrane. The above results are compared with numerical simulations that calculated by commercial code, FLUENT. The velocity of fluid in micro channel shows linear behaviors. And the mass flows are proportional to the second order function of pumping pressure that is imposed to membrane.

  • PDF

격자 볼츠만 방법을 이용한 미소 채널에서의 혼합효율 증가를 위한 수동형 믹서의 최적화 (Optimization of Passive Mixer for Enhanced Mixing in a Micro-channel by Using Lattice Bloltzmann Method)

  • 한규석;변성준;윤준용
    • 대한기계학회논문집A
    • /
    • 제29권5호
    • /
    • pp.707-715
    • /
    • 2005
  • In this work, Scalar Passive code in Lattice Boltzmann Method is employed to simulate two-phase flow of low Reynolds number in a micro-channel. The mixing characteristics in a micro-channel is a function of Peclet number. The mixing length increases with the Peclet number. It is found that with the inclusion of static elements at the channel, rapid mixing of two liquids can be achieved, as shown by the results of computer simulations. The enhancement in mixing performance is thought to be caused by the generation of eddies and by lateral velocity component when the mixture flows past static elements. The results indicate that the size of static element has more effect on the mixing than the number of static element.

마이크로 PTV 기법을 이용한 미세채널 내부 계면의 electrokinetic 효과 해석 (Micro-PIV Measurements of interfacial electrokinetic effects in a microchannel)

  • 김국배;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.49-50
    • /
    • 2002
  • In micro-channels, the electro-viscous effect is caused by the electrical double layer on pressure-driven liquid flow. Velocity fields of flow inside micro-channels were measured using micro-PIV system for investigating the electro-viscous effect. De-ionized water and aqueous NaCl solutions with four different concentrations were used as working fluid in a PDMS micro-channel of $100{\mu}m$ width and $66{\mu}m$ height. The pressure gradient, dP/dx, was determined from the pre-determined input flow rate Q of syringe pump. The mean velocity $u_m$ used for calculating Reynolds number was obtained from the PIV velocity field data. These are used to plot the pressure gradient as a function of Reynolds numbers. The pressure gradient far lower concentration solution $(10^{-5}\;M)$ was higher than that for the higher concentration solution. The increase of flow resistance was about $30\%\;and\;37.5\%$ at Re=0.02 and 0.06, respectively.

  • PDF

병렬 마이크로 채널 형상에 따른 CFD 유동해석 (CFD Analysis on the Channel Shapes of Parallel Micro-Channels)

  • 최용석;임태우;김유택;김도엽
    • 수산해양교육연구
    • /
    • 제25권5호
    • /
    • pp.1102-1109
    • /
    • 2013
  • An numerical analysis was performed to obtain the design parameters for parallel micro-channels. The parallel micro-channels consist of 10 square channels with a hydraulic diameter of 300 ${\mu}m$ and inlet/outlet manifolds. The channel length is 5mm, 10mm and 40mm respectively. Mass flux was set between 200~600kg/m2s as inlet boundary condition and atmospheric pressure was set as outlet boundary condition. The pressure drop in channels and manifolds were estimated by using the Shah and London correlation and the flow uniformity was represented by the velocity distributions with dimensionless velocity. The results show that the flow uniformity in channels depends on shapes of manifolds, length and mass flux.

미세 유체 칩 기반의 히알루론산 미세 실의 제작 (Micro-threads of Cross-linked Hyaluronic Acid Hydrogel using a Microfluidic Chip)

  • 이윤경;이광호
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.1-8
    • /
    • 2017
  • The successful synthesis of hyaluronic acid micro-threads is very promising approach for the broad application in tissue engineering such as dermal fillers. Because hyaluronic acid has the excellent biocompatibility and ability to maintain the moisture of up to several hundred times its own weight. In order to generate the hyaluronic acid micro-threads in microfluidic system, we employed two-phase flow microfluidic chip to make a rapid synthesis of the hyaluronic acid hydrogel. Hyaluronic acid was mixed with 0.02N NaOH solution and 1, 4-Butanediol diglycidyl ether (BDDE) solution and then injected into core channel. The ethanol was used for the 3-dimensional micro-thread formation in sheath channel. We manipulated the diameter of HA micro-threads using controlling of flow rates in microfluidic chip, and showed the feasibility of immobilization in HA micro-threads with florescent substances. Also, the generated HA micro-threads were evaluated and showed the suitable properties with tensile strength, bending property, and swelling profiles for dermal fillers. As a result, we suggested an innovative method for microfluidic chip-based HA micro-threads which could safely be applied as dermal filler in tissue engineering.

마이크로 혼합기 내의 유동 계측 및 혼합 특성 해석 (Analysis of Mining Performance and Flow Measurement Inside a Micro Mixer)

  • 성재용;이인원;김병균;윤의식;이인섭
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2002
  • To investigate the flow related to the mixing, micro PIV measurements were performed in the middle plane of the channel. A passive micro mixer analyzed in this work has been designed in the shape of a three-dimensional microchannel and fabricated with PDMS molding process by KAIST. The mixing performance was evaluated for different flow rates using phenolphthalein and sodium hydroxide solutions. Results show that mixing is enhanced by the increase of flow rate, which yields stronger secondary flows with helical streamlines.

  • PDF

평행류 열교환기의 열.유동 특성에 대한 설계인자의 최적화 (Optimization of Design Factors for Thermal and Flow Characteristics of a Parallel Flow Heat Exchanger)

  • 정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.640-651
    • /
    • 2000
  • For the heat and fluid flow analyses of a parallel flow heat exchanger, an improved model considering the effect of flat tube with micro-channels is proposed. The effect of flow distribution on the thermal performance of a heat exchanger is numerically investigated. The flow distribution is examined by varying geometrical parameters, i.e., the position of the separators and the inlet/outlet, and the aspect ratio of micro-channels of the heat exchanger. The flow nonuniformities along the paths of the heat exchanger are proposed and observed to evaluate the thermal performance of the heat exchanger. The optimization using ALM method has been accomplished by minimizing the flow nonuniformity. It is found that the heat transfer rate of the optimized model is increased by 6.0% of that of the reference heat exchanger model, and the pressure drop by 0.4%

수치해석을 통한 PEMFC 채널의 설계와 SU-8을 이용한 채널 제작 및 성능 평가 (Numerical Analysis-Based Design of PEMFC Channel, Fabrication of Channels, and Performance Test Using SU-8)

  • 최인재;왕학민;최갑승;김형만
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.349-354
    • /
    • 2010
  • 연료전지는 환경문제와 천연자원 고갈을 해결할 수 있기 때문에 가장 주목받고 있는 새로운 동력원이다. 본 논문에서는 마이크로 연료전지의 효율을 높이기 위해 다양한 형상에 대해 마이크로 채널에서 수소가스 유동을 수치해석 하였다. 이미 개발된 채널과 새롭게 고안된 채널, 모두 여섯 개의 다른 형상을 가진 채널이 같은 유동 특성과 경계조건으로 수치해석을 수행하였다. 수치해석 결과를 통해 유속, 유동분포, 유동균일성 등이 채널형상에 따라 영향을 많이 받는 것을 알았다. 이에 수소 가스 유동을 고려한 채널형상 최적화를 통해 연료전지의 성능을 향상시키고자 하였다. 수치해석을 통한 최적화된 채널형상을 사용한 PEMFC 실험결과 평균보다 높은 전류밀도를 나타내었다. 그러나 내구성이 낮았다.

초소수성 마이크로 채널 내 슬립 유동의 실험적 측정 (Experimental Study on Slip Flows in Superhydrophobic Microchannel)

  • 김지훈;변도영;고한서
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.84-87
    • /
    • 2007
  • Recently, many studies concern on the slip flow and slip length, which allow liquid flow to reduce drag force in microchannel. However, until now not enough investigation is performed experimentally to understand the slip flow in the superhydrophobic microchannel exhibiting riblet structures on vertical wall. Here we investigated and compared the slip flows according to the surface characteristics; hydrophilic, hydrophobic, and superhydrophobic wettabilities. Using the micro-PIV, velocity profiles can be obtained in the glass (hydrophilic), PDMS (hydrophobic), and micro-structured PDMS (superhydrophobic) microchannels. For both PDMS and superhydrophobic PDMS microchannels, we observed the slip effects showing the microscale slip lengths. Due to the micro-riblet, there are two distinctive flow characteristics on the riblet surface and the liquid meniscus in the valleys.

  • PDF

마이크로 PIV 기법을 이용한 미세채널 내부 electro-osmotic 유동 해석 (Analysis of Electro-osmotic Flow in a Micro Channel Using a Micro PIV)

  • 김양민;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.51-52
    • /
    • 2002
  • Electro-osmotic flow in a PDMS microchannel of $66{\mu}m\;\times\;200{\mu}m\;\times\;3cm$ has been investigated using a micro PIV system. The field of view was $1056{\mu}m\;\times\;200{\mu}m$ and instantaneous velocity fields were obtained using two-frame cross-correlation method with $64\;\times\;64\;pixels^2$ interrogation window. In this study, we focused on the effect of applied electric field on the variation of internal flow with varying the electric field and seeding particles. The electro-osmotic flow shows a flat velocity profile and the mean velocity is proportional to the applied electric field.

  • PDF