• Title/Summary/Keyword: micro system

Search Result 4,283, Processing Time 0.032 seconds

IN VITRO MICRO-SHEAR BOND STRENGTH OF FIVE COMPOSITE RESINS TO DENTIN WITH FIVE DIFFERENT DENTIN ADHESIVES (미세-전단 결합 강도 시험을 이용한 상아질 접착제와 수복용 복합 레진의 호환성에 관한 연구)

  • Chung, Jin-Ho;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.353-364
    • /
    • 2004
  • The purpose of this study was to compare and to evaluate the combination use of 5 kinds of dentin adhesive systems and 5 kinds of composite resins using micro-shear bond test. Five adhesive systems (Prime & Bond NT (PBN). Onecoat bond (OC), Excite (EX), Syntac (SY), Clearfil SE bond (CS)) and five composite resins (Spectrum (SP), Synergy Compact (SC), Tetric Ceram (TC), Clearfil AP-X (CA), Z100 (Z1)) were used for this study ($5{\;}{\times}{\;}5{\;}={\;}25group$, n =14/group). The slices of horizontally sectioned human tooth were bonded with each bonding system and each composite resin, and tested by a micro-shear bond strength test. These results were analyzed statistically. The mean micro-shear bond strength of dentin adhesive systems were in order of CS (22.642 MPa), SY (18.368 MPa), EX (14.599 MPa). OC (13.702 MPa). PBN (12.762 MPa). The mean bond strength of self-etching primer system group (CS, SY) in dentin was higher than that of self-priming adhesive system groups (PBN, EX, OC) significantly (P<0.05). The mean bond strength of composite resins was in order of SP (19.008 MPa), CA (17.532 MPa). SC (15.787 MPa), TC (15.068 MPa). Z1 (14.678 MPa). Micro-shear bond strength of SP was stronger than those of other composite resins significantly (P < 0.05). And those of TC and Z1 were weaker than other composite resins significantly (P < 0.05). No difference was found in micro-shear bond strength of composite resin in self-etching primer adhesive system groups (CS, SY) statistically. However, there was significant difference of micro-shear bond strength of composite resin groups in self-priming adhesive systems group (PBN, EX, OC). The combination of composite resin and dentin adhesive system recommended by manufacturer did not represent positive correlation. It didn't seem to be a significant factor.

Micro-electrode machining characteristics using the Micro-EDM (마이크로 방전가공기를 이용한 미세전극 가공특성)

  • 안현민;김영태;박성준;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1003-1007
    • /
    • 2002
  • Micro-EDM is generally used far machining micro 3-D structure. For micro-EDM, first of all, micro-electrode fabrication is needed and WEDG system is proposed for tool electrode fabrication method. When tool electrode is fabricated using WEDG system, its characteristics are under the control of many EDM parameters. Also relations between the parameters affect electrode fabrication. In this study, experiments are carried out to analyze effects of EDM parameters on micro-electrode fabrication. Experimental method and analysis are used to experimental design method. Factors used in experiments are composed of applied voltage, capacitance, wire feed rate, spindle rotating speed, machining time. As a result of experiments, wire feed rate, machining time and capacitance is proportional to gap distance(material removal), the other parameters(applied voltage, spindle rotating speed) and relations between the parameters have little influence on machining.

  • PDF

Development of micro-mold for New Injecton Molder to fabricate Micro-Nano system (Micro-Nano 시스템 제조를 위한 소형 차세대 사출기 개발과 이를 위한 Micro meld의 개발)

  • 황교일;류경주;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.910-913
    • /
    • 2002
  • Recently, the sensor and actuator are developed with EAP(Electro Active Polymer). Common used of they is close at hand, the bio chip and Lab on a chip are researched. For developed bio and micro system, a researcher applies semiconductor fabrication or make it by his hand. But, this method takes long time and a tolerance is large So they are problem of common used. So In this paper we propose the new inject ion molder and micro mold. The micro mold is different from exist ing mold. In this paper, the fabration of micro mold is introduced to inject.

  • PDF

Manipulation of Single Cell for Separation and Investigation

  • Arai, Fumihito;Ichikawa, Akihiko;Maruyama, Hisataka;Motoo, Kouhei;Fukuda, Toshio
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.135-143
    • /
    • 2004
  • Recently, high throughput screening for microorganisms with desired characteristics from a large heterogeneous population has become possible. Single cell separation has taken on increasing significance in recent years, and several different methods have been proposed so far. In this paper, we introduce several cell manipulation methods aiming at single cell separation and investigation. At first, methods for the separation of microorganisms are classified. Then, we introduce two different approaches, that is, (1) indirect manipulation using laser trapped microtools and (2) thermal gelation.

Contractile Force Measurements of Cardiac Myocytes Using a Micro-manipulation System

  • Park Suk-Ho;Ryu Seok-Kyu;Ryu Seok-Chang;Kim Deok-Ho;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.668-674
    • /
    • 2006
  • In order to develop a cell based robot, we present a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source. The proposed measurement system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recording system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitudes of the contractile force of each cardiac myocyte under different conditions were compared. From the quantitative experimental results, we could estimate that the force of cardiac myocytes is about $20\sim40{\mu}N$, and show that there are differences between the control cells and the micro-patterned cells.

Effect of Combination with Aspherical Lens in the Micro Optical System Design (마이크로 광학계의 설계에서 비구면 렌즈의 조합 효과)

  • 김명중;김한섭;박규열;전종업;김의중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1422-1425
    • /
    • 2003
  • In the design of optical system, important variables of optical system (including indices, shapes, spaces, stops. etc.) must manipulate in order to balance out offensive aberration. In this paper, it carried out a basic study on the design of micro optical system usable for the acquaintance of visual information in the particular conditions such as capsule type endoscopes. In this study, specification for design of optical system selected voluntarily and the basic design of optical system carried out by using the ray tracing method on the assumption that ideal lenses without aberrations. In the designed optical system, the optimization including aberration correction and the performance evaluation of optical system carried out by using the CODE-V. The final designed optical system consists of seven sheets of lenses. Also the results of performance evaluation. the micro optical system combined with aspherical lenses was confirmed to have improved optical performance as compared with the micro optical system consisted of spherical lenses.

  • PDF

A Study on the Micro Pattern Fabrication of Lab-on-a-chip Mold Master using Micro EDM (Micro EDM을 이용한 Lab-on-a-chip금형의 미세 패턴 제작에 관한 연구)

  • Shin, B.C.;Kim, K.B.;Cho, M.W.;Kim, B.H.;Jung, W.C.;Heo, Y.M.
    • Transactions of Materials Processing
    • /
    • v.20 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • Recently, analyzing system is studying for applying to biomedical engineering field, actively. Micro fluidics control system has been manufactured using LIGA (Lithographie Galvanoformung und Abformung), Etching, Lithography and Laser etc. However, it is difficult that above-mentioned methods are applied to fabrication of precision mold master efficiently because of long processing time and rising cost of equipments. Therefore, in this study, micro EDM and micro WEDG system were developed to analyze machining characteristics with tool wear, surface roughness and process time. Then, optimal machining conditions could be obtained from the results of analysis. As the results, mold master of staggered herringbone mixer which has a high mixing efficiency, one of passive mixer of Lab-on-a-chip, could be fabricated from micro pattern(< 50um) using micro EDM successfully.

An Operation and Control Algorithm of Micro-grid (차세대전력공급네트워크(Micro-grid)의 운용제어앨고리즘)

  • Rho, Dae-Seok;Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.232-239
    • /
    • 2007
  • There is an increasing concern to interconnect DG(Distributed Generation) units into a distribution system and operate and maintain the system power quality within a proper level to distribution companies, regional electricity utilities and industrial customers. Recently, this situation makes many experts estimate a next generation of distribution system which is composed of some micro-grids. But the proposed micro-grid is only mentioned as a small grid with some DG units, some power quality compensators, communication and control equipments. In this paper, a topology and an operation/control algorithm of the micro-grid which is able to supply the electricity with high reliability and quality, are proposed.

  • PDF

Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique (마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상)

  • Kim D.I.;Huh Y.H.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

A Study on Determining the Size of the Interface Inductor for Grid-Connected Micro-Sources (Micro-Source의 계통 연계용 인덕터 크기 선정에 관한 연구)

  • Son, Kwang-Myung;Kim, Young-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.52-58
    • /
    • 2005
  • The concept of the Micro-Grid comprising Micro-Sources supplying both heat and power ranging from several [KW] to 1[MW] to local customers is proposed by CERTS(Consortium for Electric Reliability Technology Solutions). Micro-Sources adopt environmentally friendly and reliable power sources such as Fuel-Cell and Micro-Turbines. Micro-Sources adopt voltage source inverter with AC grid system in order to provide independent real and reactive power control for premium power quality. Thus Micro-Source needs series inductance for interfacing with AC grid system. With this reason, we propose a technique that can decide the optimal size of the inductor for effective transfer of the power into the grid.