• 제목/요약/키워드: micro coil

검색결과 133건 처리시간 0.026초

유한요소법을 사용한 주사전자 현미경의 전자렌즈 설계 및 해석에 관한 연구 (A Study on Design and Analysis for Magnetic Lenses of a Scanning Electron Microscope using Finite Element Method)

  • 박근;정현우;박만진;김동환;장동영
    • 한국정밀공학회지
    • /
    • 제24권9호
    • /
    • pp.95-102
    • /
    • 2007
  • The scanning electron microscope (SEM) is one of the most popular instruments available for the measurement and analysis of the micro/nano structures. It is equipped with an electron optical system that consists of an electron beam source, magnetic lenses, apertures, deflection coils, and a detector. The magnetic lenses playa role in refracting electron beams to obtain a focused spot using the magnetic field driven by an electric current from a coil. A SEM column usually contains two condenser lenses and an objective lens. The condenser lenses generate a magnetic field that forces the electron beams to form crossovers at desired locations. The objective lens then focuses the electron beams on the specimen. The present work concerns finite element analysis for the electron magnetic lenses so as to analyze their magnetic characteristics. To improve the performance of the magnetic lenses, the effect of the excitation current and pole-piece design on the amount of resulting magnetic fields and their peak locations are analyzed through the finite element analysis.

Velocity and temperature profiles of Al/water micro fluid in a circular tube with swirl

  • Chang, Tae-Hyun;Lee, Kwon Soo;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권7호
    • /
    • pp.677-684
    • /
    • 2013
  • A lot study of convection heat transfer on internal flow has been extensively conducted in the past decades using of high specific surface area, increasing heat transfer coefficient, swirling flow and improving the transport properties. This study concerned with the application of a tangential slot swirl generator for improving heat transfer in a horizontal circular copper tube. The Al particles(about $100{\sim}130{\mu}m$) was employed for this experimental work. 3D PIV(particle image velocimetry) technique has employed to measure velocity profiles of Al particles with and without swirl flow. The copper tube is heated uniformly by winding of a heating coil for heat transfer work, having a resistance of 9 ohm per meter. Experiments are performed in the Reynolds number range of 6,800~12,100 with swirl and without swirl using Al particles. Experimental data for comparison of Nusselt number is presented that of with swirl and without swirl along the test tube for the Reynolds numbers. The Nusselt number is improved with increasing of Reynolds numbers or swirl intensities along the test tube. The Nusselt number with swirl flow is about 60.0% to 119.0% higher than that obtained by the Dittus-Boelter equation.

A Study on Performance Analysis of the Helically Coiled Evaporator with Circular Minichannels

  • Kim Ju-Won;Im Yong-Bin;Kim Jong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1059-1067
    • /
    • 2006
  • In order to develop a compact evaporator, experiments that show characteristics of evaporating heat transfer and pressure drop in the helically coiled minichannel were performed in our previous research. This study was focused on the performance analysis of helically coiled heat exchangers with circular minichannels with an inner diameter=1.0 mm. The working fluid was R-22, and the properties of R-22 were estimated using the REFPROP program. Numerical simulation was performed to compare results with the experimental results of the helically coiled heat exchanger. As the heat transfer rate and pressure drop were calculated at the micro segment of the branch channels, the performance of the evaporator was evaluated. The following conclusions were obtained through the numerical simulations of the helically coiled heat exchanger. It showed good performance when the flow rate of each branch channels was suitable to heat load of air-side. The numerical simulation value agreed with experimental results within ${\pm}15%$. In this study, a numerical simulation program was developed to estimate the performance of a helically coiled evaporator. And, an optimum helically coiled minichannels evaporator was designed.

초소형 광자기 드라이브용 서스펜션의 동특성 해석 (Dynamic Analysis of Suspension for Small Form Factor MO Drive)

  • 홍어진;오우석;박노철;양현석;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.406-411
    • /
    • 2003
  • One of the trends on information storage device is focused on the development of micro-optical devices with OFH (Optical Flying Head). Many different types of sliders for OFH and optical component systems have been introduced in the literature. However, the important issue on the mechanical system, which consists of suspension, swing arm and VCM (Voice Coil Motor) part has not been discussed up to date. In this research, we analyses the suspension, which is used for the small form factor MO drive. The analysis is in process two ways. One is probabilistic analysis, another is dynamic shock analysis. Probabilistic analysis is a technique you can use to assess the effect of uncertain input parameters and assumptions on your analysis model. Using a probabilistic analysis you can and out how much the results of a finite elements analysis are affected by uncertainties in the model. Dynamic shock analysis is used for the mobile applications. The mechanical robustness of the suspension simulating the shock responses of a disk-suspension is proposed in this paper.

  • PDF

위상-치수 최적화에 의한 마이크로 구동기 판 스프링의 설계 (Plate Spring Design of a Micro Actuator Using Topology-parameter Optimization)

  • 이종진;이호철;유정훈
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1246-1253
    • /
    • 2007
  • The recent issue of optical pickup actuators is to apply optical storage devices to mobile devices such as a cellular phone and PDA. It requires actuators to become smaller than conventional types. As the size becomes smaller, the magnetic force is reduced and the assembly of optical pickup actuators becomes more difficult. In addition, its dynamic characteristics are changed. In this paper, methods to improve magnetic forces and dynamic characteristics are suggested and the optimal result of the plate spring design is obtained. A diamond shape magnet and the fine pattern coil (FPC) are used to improve magnetic forces and damping elements are attached to decrease the peak magnitude of the mode instead of using structural damping, mostly for the purpose of improving the accuracy of the finite element simulation. To get more stable dynamic characteristics than conventional ones, a plate spring is applied to the optical pickup actuator and it is optimized with topology and parameter optimization to obtain the concept and the detail design, respectively.

Preparation and Characterization of Nanoparticles Using Poly(N-isopropylacrylamide)-$Poly({\varepsilon}-caprolactone)$ and Poly(ethylene glycol)-$Poly({\varepsilon}-caprolactone)$ Block Copolymers with Thermosensitive Function

  • Choi, Chang-Yong;Jang, Mi-Kyeong;Nah, Jae-Woon
    • Macromolecular Research
    • /
    • 제15권7호
    • /
    • pp.623-632
    • /
    • 2007
  • Thermosensitive nanoparticles were prepared via the self-assembly of two different $poly({\varepsilon}-caprolactone)$-based block copolymers of poly(N-isopropylacrylamide)-b-$poly({\varepsilon}-caprolactone)$ (PNPCL) and poly(ethylene glycol)-b-$poly({\varepsilon}-caprolactone)$ (PEGCL). The self-aggregation and thermosensitive behaviors of the mixed nanoparticles were investigated using $^1H-NMR$, turbidimetry, differential scanning microcalorimetry (micro-DSC), dynamic light scattering (DLS), and fluorescence spectroscopy. The copolymer mixtures (mixed nanoparticles, M1-M5, with different PNPCL content) formed nano-sized self-aggregates in an aqueous environment via the intra- and/or intermolecular association of hydrophobic PCL chains. The microscopic investigation of the mixed nanoparticles showed that the critical aggregation concentration (cac), the partition equilibrium constants $(K_v)$ of pyrene, and the aggregation number of PCL chains per one hydrophobic microdomain varied in accordance with the compositions of the mixed nanoparticles. Furthermore, the PNPCL harboring mixed nanoparticles evidenced phase transition behavior, originated by coil to the globule transition of PNiPAAm block upon heating, thereby resulting in the turbidity change, endothermic heat exchange, and particle size reduction upon heating. The drug release tests showed that the formation of the thermosensitive hydrogel layer enhanced the sustained drug release patterns by functioning as an additional diffusion barrier.

Steam generator performance improvements for integral small modular reactors

  • Ilyas, Muhammad;Aydogan, Fatih
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1669-1679
    • /
    • 2017
  • Background: Steam generator (SG) is one of the significant components in the nuclear steam supply system. A variety of SGs have been designed and used in nuclear reactor systems. Every SG has advantages and disadvantages. A brief account of some of the existing SG designs is presented in this study. A high surface to volume ratio of a SG is required in small modular reactors to occupy the least space. In this paper, performance improvement for SGs of integral small modular reactor is proposed. Aims/Methods: For this purpose, cross-grooved microfins have been incorporated on the inner surface of the helical tube to enhance heat transfer. The primary objective of this work is to investigate thermal-hydraulic behavior of the proposed improvements through modeling in RELAP5-3D. Results and Conclusions: The results are compared with helical-coiled SGs being used in IRIS (International Reactor Innovative and Secure). The results show that the tube length reduces up to 11.56% keeping thermal and hydraulic conditions fixed. In the case of fixed size, the steam outlet temperature increases from 590.1 K to 597.0 K and the capability of power transfer from primary to secondary also increases. However, these advantages are associated with some extra pressure drop, which has to be compensated.

인체 삽입용 LC 공진형 혈압 센서 디자인 및 제작 (Design and Fabrication of Implantable LC Resonant Blood Pressure Sensor)

  • 김진태;김성일;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제26권3호
    • /
    • pp.171-176
    • /
    • 2013
  • In this paper, we present a MEMS (micro-electro-mechanical system) implantable blood pressure sensor which has designed and fabricated with consideration of size, design flexibility, and wireless detection. Mechanical and electrical characterizations of the sensor were obtained by mathematical analysis and computer aided simulation. The sensor is composed of two coils and a air gap capacitor formed by separation of the coils. Therefore, the sensor produces its resonant frequency which is changed by external pressure variation. This frequency movement is detected by inductive coupling between the sensor and an external antenna coil. Theoretically analyzed resonant frequency of the sensor under 760 mmHg was calculated to 269.556 MHz. Fused silica was selected as sensor material with consideration of chemical and electrical reaction of human body to the material. $2mm{\times}5mm{\times}0.5mm$ pressure sensors fitted to radial artery were fabricated on the substrates by consecutive microfabrication processes: sputtering, etching, photolithography, direct bonding and laser welding. Resonant frequencies of the fabricated sensors were in the range of 269~284 MHz under 760 mmHg pressure.

Measuring T1 contrast in ex-vivo prostate tissue at the Earth's magnetic field

  • Oh, Sangwon;Han, Jae Ho;Kwon, Ji Eun;Shim, Jeong Hyun;Lee, Seong-Joo;Hwang, Seong-Min;Hilschenz, Ingo;Kim, Kiwoong
    • 한국자기공명학회논문지
    • /
    • 제23권1호
    • /
    • pp.12-19
    • /
    • 2019
  • A former study has shown that the spin-lattice relaxation time ($T_1$) in cancerous prostate tissue had enhanced contrast at an ultra-low magnetic field, $132{\mu}T$. To study the field dependence and the origin of the contrast we measured $T_1$ in pairs of ex-vivo prostate tissues at the Earth's magnetic field. A portable and coil-based nuclear magnetic resonance (NMR) system was adopted for $T_1$ measurements at $40{\mu}T$. The $T_1$ contrast, ${\delta}=1-T_1$ (more cancer)/$T_1$(less cancer), was calculated from each pair. Additionally, we performed pathological examinations such as Gleason's score, cell proliferation index, and micro-vessel density (MVD), to quantify correlations between the pathological parameters and $T_1$ of the cancerous prostate tissues.

초고해상도 미세영상 기법을 이용한 Mouse 뇌의 자기공명영상 연구 (High-Resolution MRI Study on Mouse Brain Using Micro-Imaging)

  • 한덕영;윤문현;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.142-147
    • /
    • 2008
  • 목적 : 본 연구는 핵자기공명 분광기를 개조한 미세영상 기법을 이용하여, 동물실험에 주류를 이루는 mouse를 대상으로, 0.1 mm 이내의 초고해상도 자기공명영상을 5분 정도 시간 안에 획득할 수 있는 방법을 개발하고자 하였다. 대상 및 방법 : 사용된 mouse는 C57BL/6로서 무게 50 그램 이내의 mouse를 사용하였다. 본 연구에 활용된 초전도 자석은 구경 89 mm, 4.7 T의 자기장 세기를 가진 수직형 자석이며, 사용된 샘플 코일의 직경은 30 mm 이고, 사용된 펄스시퀀스는 fast spin echo (FSE) 및 gradient echo (GE) 기법들이다. 결과 : 최적의 자기공명영상 파라미터를 확보하면서 2차원 영상으로서 수소밀도 및 T2 강조 영상을 획득하였다. 영상으로부터 mouse 뇌의 미세부분까지 상세히 해부학적 구조를 확인할 수 있었고, 또한 입체적인 정보를 획득하기 위하여 3D 영상도 부가적으로 획득하였다. 조영제를 이용한 dynamic contrast 연구에 3D 영상이 매우 유용하였다. 결론 : 본 연구를 통하여 mouse 뇌에 대한 고해상도 자기공명영상 획득을 위한 최적의 파라미터를 확보할 수 있었고, 또한 성공적인 자기공명영상도 획득하였다. 즉, 사람이나 다른 소동물뇌의 경우와 같이 mouse 뇌 조직의 다양한 부위의 미세부분을 확인할 수 있는 충분한 고해상도의 영상을 획득하였다. 최근 국내에서 mouse를 이용한 자기공명영상 연구가 시작되었으나 아직 초기단계라고 평가할 수 있고, mouse는 다른 동물에 비하여 취급/관리하기 쉬우므로 향후 mouse를 이용한 뇌 연구가 활성화 될 것으로 사료된다.

  • PDF