• Title/Summary/Keyword: metal working operation

Search Result 33, Processing Time 0.024 seconds

Long-Term Life Test of A Stainless Steel-Sodium Heat Pipe (스테인리스 스틸-나트륨 히트파이프의 장기 수명 시험)

  • Park, S.Y.;Jung, E.G.;Boo, J.H.;Kang, H.K.;Yoo, J.H.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1058-1062
    • /
    • 2004
  • High-temperature cylindrical stainless steel/sodium heat pipe was manufactured and tested under long-term operation. The container material was stainless steel 316L and the working fluid was sodium. The heat pipe was 25.4 mm in diameter and 1000 mm in length with a two-layer screen mesh wick. The evaporator part was 600 mm and the condenser part was 300 mm in length. Total measurement points on heat pipe were 15 points and 12 points were located in condenser part. The heat pipe was heated for 142 days(3400 hours) at $800^{\circ}C$. In the test period, the maximum temperature difference was increased from $18^{\circ}C$ o $28^{\circ}C$ and the maximum thermal resistance was as low as $0.015^{\circ}CW$.

  • PDF

Gaseous Changes during Discharge ant Thermal Treatment in Plasma Display Panel (PDP)

  • Hwang, Ji-Hee;Yang, Seung-Jean;Jun, Moon-Gue;Kim, Young-Chai
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1199-1202
    • /
    • 2005
  • Inside of working PDP, there exist highly reactive conditions in the gap between two glass panels. MgO film and phosphor have been investigated as a function of discharge, also phosphor and sealing frits have been investigated as a function of temperature. Changes of impurity generation of MgO, phosphor and sealing fits were measured by using x-ray photoelectron spectroscopy (XPS) and quadropole mass spectroscopy (XPS) and quadropole mass spectrometer (QMS). Impurities such as CO, $CO_2$, OH and $H_2O$ were increased during discharge and heating treatment. Gaseous impurities such as carbon compounds and water deteriorated the characteristics of PDP operation during of lifetime. So metal is used to remove the impurities of phosphor and sealing frits during hearting, the result that the quantity of the impurities such as carbon monoxide and water was reduced.

  • PDF

Control of Ground Surface Using Light Scattering (광산란법을 이용한 연삭표면 제어)

  • 홍민성
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.293-298
    • /
    • 1998
  • In surface grinding, the conditions of the grinding wheel give a significant effect on the ground workpieces comparing with other metal removal processes. In this paper, to assist the development, a non-contacting optical method is introduced to make in-process measurements of scattering intensities from laser beam during surface grinding processes. This show indications of changes in surface texture of wheel working surfaces. Also, in order to determine the dressing time monitoring method of grinding wheel in surface grinding, a three-dimensional computer simulation of the grinding operation has been attempted based on the contact mechanism and surface-shaping system between the grinding wheel and the workpiece. The optical dressing time is determined based on the amount of the grain wear and work surface roughness.

  • PDF

Environment-Friendly Metal Cutting Technology using Cooled Air (냉각공기에 의한 환경 친화적 절삭가공기술)

  • Lee, Jong-Hang;Cho, Woong-Shik;Chung, Joon-Ki;Park, Ceol-Woo;Kim, Young-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.114-120
    • /
    • 2001
  • It is necessary to develop a new metal cutting technology which does not use cutting fluid, since cutting fluid can have undesirable effect on workers's health and working environment. For this to be possible, it is necessary to replace the conventional method of using cutting fluid, whose basic functions are removing chip and heat, and providing lubrication between tool and chip. In this work, cooled air is utilized in order to replace cutting fluid. Experiments were carried out while cutting workpiece with HSS flat endmill under a variety of supply conditions for cooled air. Also the performance characteristics of the air cooling system. which was built for the experiments, were carefully analyzed. For the reliable operation of air cooling system. moisture contained in the cooled air had to be removed before being supplied to the workpiece and tools. It was found that depending on the amount of its flow rate the temperature of cooled air changes at the time of injection from the nozzle. The flow rate of cooled air also plays an important role in removing the accumulated chip on the workpiece. After comparing the flank wear for the three cases of using cooled air, cutting fluid, and pure dry technique, it was demonstrated that the level of flank wear was similar for the cases of cooled air and cutting fluid. The pure dry technique, however, showed higher level of flank wear than cooled air.

  • PDF

A SURVER OF THE ACTUAL CONDITIONS ON THE PRODUCTION OF DENTAL PROSTHESIS (치과보철기공물 제작실태에 관한 조사연구)

  • Bae, Jung-Soo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.358-394
    • /
    • 1995
  • The author studied the actual conditions on the production of dental prosthesis made in laboratories, and also studied interrelationships between dentists and laboratory technicians in both personal and technical aspects. Two hundred-eighty four technicians, work in dental laboratories presently, were surveyed via mail and direct contact during the period from June 1 to June 30 and August 27 to August 28 in 1994 respectively. The obtained results were as follows : 1. Among the respondents, 90.5% we re working in commercial dental laboratories and their laboratories were mainly located in the Seoul area(40.9%, P<0.05). The numbers of employees in these laboratories were less than 10 persons(70.0%, P<0.01), and 75.9% of these laboratories have been in operation less than 15 years. 2. Most laboratory procedures were accomplished according to established disciplines. However, procedures such as die trimming in fixed restorations and the qualifications of the people designing removable partial dentures were not. Other problem areas were boxing of the working cast, the person determining the posterior palatal seal area, selection and arrangement of artificial teeth, occlusion rim correction and laboratory remounting of the processed denture in complete denture restorations. 3. Only half of the requesting dentists could send work authorizations to the laboratories with their work and even so, its contents were quite lacking. Consequently, there must be some standards in writing work authorization. 4. Technicians most desired clean and accurate impressions in fixed and removable dentures, and enough tooth reduction in porcelain fused to metal restorations. 5. For the establishment of better relationships between dentist and dental technician, the respondents desired the establishment of equal footing first(33.5%), and frequent conversations and muture understanding second(25.9%).

  • PDF

The Role of Metal Catalyst on Water Permeation and Stability of BaCe0.8Y0.2O3-δ

  • Al, S.;Zhang, G.
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.212-219
    • /
    • 2018
  • Perovskite type ceramic membranes which exhibit dual ion conduction (proton and oxygen ion conduction) can permeate water and can aid solving operational problems such as temperature gradient and carbon deposition associated with a working solid oxide fuel cell. From this point of view, it is crucial to reveal water transport mechanism and especially the nature of the surface sites that is necessary for water incorporation and evolution. $BaCe_{0.8}Y_{0.2}O_{3-{\alpha}}$ (BCY20) was used as a model proton and oxygen ion conducting membrane in this work. Four different catalytically modified membrane configurations were used for the investigations and water flux was measured as a function of temperature. In addition, CO was introduced to the permeate side in order to test the stability of membrane against water and $CO/CO_2$ and post operation analysis of used membranes were carried out. The results revealed that water incorporation occurs on any exposed electrolyte surface. However, the magnitude of water permeation changes depending on which membrane surface is catalytically modified. The platinum increases the water flux on the feed side whilst it decreases the flux on the permeate side. Water flux measurements suggest that platinum can block water permeation on the permeate side by reducing the access to the lattice oxygen in the surface layer.

ANALYSIS OF HEAT TRANSFER ON SPENT FUEL DRY CASK DURING SHORT-TERM OPERATIONS (사용후핵연료 건식 용기의 단기운영공정 열전달 평가)

  • Kim, H.;Lee, D.G.;Kang, G.U.;Cho, C.H.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.54-61
    • /
    • 2016
  • When spent fuel assemblies from the reactor of nuclear power plants(NPPs) are transported, the assemblies are exposed to short-term operations that can affect the peak cladding temperature of spent fuel assemblies. Therefore, it needs to perform the analysis of heat transfer on spent fuel dry cask during the operation. For 3 dimensional computational fluid dynamnics(CFD) simulation, it is proposed that the short-term operation is divided into three processes: Wet, dry, and vacuum drying condition. The three processes have different heat transfer mode and medium. Metal transportation cask, which is Korea Radioactive Waste Agency(KORAD)'s developing cask, is evaluated by the methods proposed in this work. During working hours, the boiling at wet process does not occur in the cask and the peak cladding temperatures of all processes remain below $400^{\circ}C$. The maximum peak cladding temperature is $173.8^{\circ}C$ at vacuum drying process and the temperature rise of dry, and vacuum drying process occurs steeply.

Separator Effect on the Cell Failure of Lithium Secondary Battery using Lithium Metal Electrode (리튬금속 전극을 이용한 리튬이차전지의 내부단락에 대한 분리막의 영향)

  • Kim, Ju-Seok;Bae, Sang-Ho;Hwang, Min-Ji;Heo, Min-Yeong;Doh, Chil-Hoon
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.171-175
    • /
    • 2011
  • Lithium secondary batteries using lithium metal count electrode are easy to use and to analyze the specific characteristics of working electrode. Nevertheless, during the charge operation internal electrical short circuit could be caused by the dendritic growth of lithium. The cell failure by the short circuit depends on the condition of separator such as constitutive material and thickness. To prevent the cell failure caused by the dendritic growth of lithium, the electrochemical properties of the cell of lithium metal count electrode were evaluated for four different kinds of separator. Among the tested separators, GMF (glass micro-fiber filter, $300{\mu}m$) was the most promising one because it could effectively prevent the cell failure during the charge. The cell using GMF separator had relatively low impedance. Generally the cell using thicker separator than $50{\mu}m$ could effectively avoid the cell failure by internal short circuit and had the good cycleability. The highest rate capability by the signature method was acquired in the case of GMF separator.

Exposure status of welding fumes for operators of overhead traveling crane in a shipyard (대형조선소 천장크레인 운전원의 용접흄 노출 실태)

  • Lee, Kyeongmin;Kim, Boowook;Kwak, Hyunseok;Ha, Hyunchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

Implementation of an Instruction Buffer to process Variable-Length Instructions (가변 길이 명령어 처리를 위한 명령어 버퍼 구현)

  • 박주현;김영민
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.12
    • /
    • pp.66-76
    • /
    • 1998
  • In this paper, we implement a buffer capable of handling short loops references to statistically lower the miss rate of variable-length instructions stored in the instruction buffer. MAU(Mark Appending Unit) takes the instructions as they are fetched from external memory, performs some initial decode operations and stores the results of the decode in the buffer for reducing multiple decodes when instructions are executed repeatedly such as in a loop. It includes a decision block of whether hit or not for effectively processing branch instructions Each module of the proposed architecture of processing variable-length instruction is described in VHDL structurally and behaviorally and whether it is working well or not is checked on V-System simulator of Model Technology Inc. We synthesized and simulated the architecture using an ASIC Synthesizer tool with 0.6$\mu\textrm{m}$ 5-Volt CMOS COMPASS library. Operation speed is up to 140MHz. The architecture includes about 17,000 gates.

  • PDF