• Title/Summary/Keyword: metal substructures

Search Result 12, Processing Time 0.023 seconds

A study on the difference analysis between an ideal and a clinical shape in case of manufacturing a metal-ceramic pontic substructure (금속-도재 가공치 하부구조 제작에서 이상적인 형태와 임상에서 사용되는 형태의 차이 분석)

  • Kim, Wook-Tae;Im, Su-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.8-15
    • /
    • 2016
  • Purpose: The purpose of this research is to determine whether pontic metal substructures, which are currently used in clinical surgeries, are designed appropriately and identify the problems that can occur due to their shape, size, and position. Then it aimed to emphasize the importance of making and designing pontic metal substructures based on basic principles. Materials and Methods: This research measured pontic basal surface (P1) used sample metal substructures in this study, gingiva margin (P2), and the porcelain thickness of maximum infrabulge of labial surface around 1/3 of cervix dentis (P3). One-way ANOVA analysis was carried out to test the differences among groups, Tukey Honestly Significant Difference Test was conducted for statistical analysis among groups. Results: For porcelain thickness and SD value, the P1 part was $1.2-1.8({\pm}0.17)mm$ for experimental group 1, $1.2-1.7({\pm}0.17)mm$ for experimental group 2, and $0.4-2.8({\pm}0.92)mm$ for experimental group 3. Next, the P2 part was $1.4-1.6({\pm}0.07)mm$ for experimental group 1, $1.3-1.8({\pm}0.07)mm$ for experimental group 2, and $0.5-2.7({\pm}0.67)mm$ for experimental group 3. The P3 part was $1.4-1.7({\pm}0.10)mm$ for experimental group 1, $1.5-2({\pm}0.10)mm$ for experimental group 2, and $0.9-3.1mm({\pm}0.90)$ for experimental group 3. There was no significance when One-way ANOVA analysis/Tukey Honestly Significant Difference Test was conducted for statistical analysis among groups (P > 0.05). Conclusion: The suggested metal substructures can be used clinically as they meet the requirements that pontic must have.

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2014
  • Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

The Early Assembly History of the Milky Way with Extremely Metal-Poor ([Fe/H] < -3.0) Stars

  • Jeong, Miji;Lee, Young Sun;Kim, Young Kwang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.59.1-59.1
    • /
    • 2020
  • Extremely metal-poor (EMP; [Fe/H] < -3.0) stars are thought to be genuine second-generation of stars because they were born from relatively pristine gas chemically enriched by one or two supernovae. So, the EMP stars presumably originated from outside the Milky Way (MW) are important tracers for the early chemical evolution and assembly history of the MW. In this study, we present the preliminary results on the early assembly history of the MW inferred by associating the dynamical properties of our EMP stars with those of known substructures in the MW. We also explore the star formation history of the progenitor galaxies of our EMP stars by investigating the elemental abundances of the EMP stars associated with the substructure.

  • PDF

Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces

  • Ozer, Fusun;Pak-Tunc, Elif;Dagli, Nesrin Esen;Ramachandran, Deepika;Sen, Deniz;Blatz, Markus Bernhard
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.340-346
    • /
    • 2018
  • PURPOSE. In this study, the shear bond strengths (SBS) of luting cements to fixed superstructure metal surfaces under various seating forces were investigated. MATERIALS AND METHODS. Seven different cements [Polycarboxylate (PCC), Glass-Ionomer (GIC), Zinc phospahate (ZPC), Self-adhesive resin (RXU), Resin (C&B), and Temporary cements ((RXT) and (TCS))] were bonded to a total number of 224 square blocks ($5{\times}5{\times}3mm$) made of one pure metal [Titanium (CP Ti) and two metal alloys [Gold-Platinum (Au-Pt) and Cobalt-Chrome (Co-Cr)] under 10 N and 50 N seating forces. SBS values were determined and data were analyzed with 3-way ANOVA. Pairwise comparisons and interactions among groups were analyzed with Tukey's simultaneous confidence intervals. RESULTS. Overall mean scores indicated that Co-Cr showed the highest SBS values ($1.96{\pm}0.4$) (P<.00), while Au-Pt showed the lowest among all metals tested ($1.57{\pm}0.4$) (P<.00). Except for PCC/CP Ti, RXU/CP Ti, and GIC/Au-Pt factor level combinations (P<.00), the cements tested under 10 N seating force showed no significantly higher SBS values when compared to the values of those tested under 50 N seating force (P>.05). The PCC cement showed the highest mean SBS score ($3.59{\pm}0.07$) among all cements tested (P<.00), while the resin-based temporary luting cement RXT showed the lowest ($0.39{\pm}0.07$) (P<.00). CONCLUSION. Polycarboxylate cement provides reliable bonding performance to metal surfaces. Resin-based temporary luting cements can be used when retrievability is needed. GIC is not suitable for permanent cementation of fixed dental prostheses consisting of CP Ti or Au-Pt substructures.

Clinical Experiment Results of Cerec Inlab using Vita9 (VITA VM9 Zirconia powder를 이용한 Cerec inlab의 임상증례에 관하여)

  • Jung, Hyo-Kyung;kim, Jeong-Sook;Lee, Jong-Do
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Although there are many different ways that restorations can be made, it can be said that the biocompatibility of abutment and crown is very important in this experiment. When placed in the actual oral cavity, the differences were obvious. Compared to In-ceram Aluminium, the structure that is obtained after firing reveals a particularly homogeneous distribution of the crystal and glass phase. The In-ceram aluminium system had many problems, such as having weak tensile strength, and having low bonding strength due to the shrinking that occurs after firing. Because of the opaque finish of the metal frame, the two may look similar from the outside, but it is evident that there are differences between using a metal frame and In-ceram. VITA VM9 has been designed as a special ceramic featuring a fine structure or stabilized Zro2 substructures, and so the VITA VM9 excels in its light refraction and reflection behavior, which is similar to natural teeth. It also has outstanding chemical balance, which presents advantages such as considerably reduced accumulation of plaque on the ceramic surface.? This ultimately results in easier care and cleaning for the patient.

  • PDF

Tungsten-Titanium Powder Compaction by Impulsive Loading (I) (W-Ti 분말 압축 (I))

  • Dal Sun Kim;S.Nemat-Nasser
    • Explosives and Blasting
    • /
    • v.19 no.1
    • /
    • pp.101-110
    • /
    • 2001
  • Depleted uranium (DU) outperforms tungsten heavy alloys (WHA) by about 10%. Because of environmental and hence, political concerns, there is a need to improve WHA performance, in order to replace the DU penetrators. A technique of metal powder compaction by the detonation of an explosive has been applied to tungsten-titanium(W-Ti) powder materials that otherwise may be difficult to fabricate conventionally or have dissimilar, nonequilibrium, or unique me1astab1e substructures. However, the engineering properties of compacted materials are not widely reported and are little known especially for the "unique" composition of W-Ti alloy. To develop high-performance tungsten composites with superior ballistic attributes, it is necessary to understand, carefully document controlled experimental results, and develop basic computational models for potential composites with controlled microstructures. A detailed understanding and engineering application of W-Ti alloy can lead to the development of new structural design for engineering components and materials.

  • PDF

Observational Evidence of Merging and Accretion in the Milky Way Galaxy from the Spatial Distribution of Stars in Globular Clusters

  • Chun, Sang-Hyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.76-76
    • /
    • 2013
  • The current hierarchical model of galaxy formation predicts that galaxy halos contain merger relics in the form of long stellar streams. In order to find stellar substructures in galaxy, we focused our investigation on the stellar spatial density around globular clusters and on the quantitative properties of the evolved sequences in the color-magnitude diagrams (CMDs). First, we investigated the spatial configuration of stars around five metal-poor globular clusters in halo region (M15, M30, M53, NGC 5053, and NGC 5466) and one metal-poor globular cluster in bulge region (NGC 6626). Our findings indicate that all of these globular clusters show strong evidence of extratidal features in the form of extended tidal tails around the clusters. The orientations of the extratidal features show the signatures of tidal tails tracing the clusters' orbits and the effects of dynamical interactions with the galaxy. These features were also confirmed by the radial surface density profiles and azimuthal number density profiles. Our results suggest that these six globular clusters are potentially associated with the satellite galaxies merged into the Milky Way. Second, we derived the morphological parameters of the red giant branch (RGB) from the near-infrared CMDs of 12 metal-poor globular clusters in the Galactic bulge. The photometric RGB shape indices such as colors at fixed magnitudes, magnitudes at fixed colors, and the RGB slope were measured for each cluster. The magnitudes of the RGB bump and tip were also estimated. The derived RGB parameters were used to examine the overall behavior of the RGB morphology as a function of cluster metallicity. The behavior of the RGB shape parameters was also compared with the previous observational calibration relation and theoretical predictions of the Yonsei-Yale isochrones. Our results of studies for stellar spatial distribution around globular clusters and the morphological properties of RGB stars in globular clusters could add further observational evidence of merging scenario of galaxy formation.

  • PDF

Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

  • Suputtamongkol, Kallaya;Tulapornchai, Chantana;Mamani, Jatuphol;Kamchatphai, Wannaporn;Thongpun, Noparat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.319-325
    • /
    • 2013
  • PURPOSE. The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS. Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at ${\alpha}$=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS. $L^*$, $a^*$, and $b^*$ values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ${\Delta}E{^*}_{ab}$ values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION. No significant differences were observed between the $L^*$, $a^*$, and $b^*$ values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ${\Delta}E{^*}_{ab}$ values.

What is the changing frequency of diamond burs?

  • Emir, Faruk;Ayyildiz, Simel;Sahin, Cem
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2018
  • PURPOSE. The purpose of this study was to determine the changing frequency of a diamond bur after multiple usages on 3 different surfaces. MATERIALS AND METHODS. Human premolar teeth (N = 26), disc shaped direct metal laser sintered CoCr (N = 3) and zirconia specimens (N = 3) were used in this study. Groups named basically as Group T for teeth, Group M for CoCr, and Group Z for zirconia. Round tapered black-band diamond bur was used. The specimens were randomly divided into three groups and placed with a special assembly onto the surveyor. 1, 5, and 10 preparation protocols were performed to the first, second, and third sub-groups, respectively. The subgroups were named according to preparation numbers (1, 5, 10). The mentioned bur of each group was then used at another horizontal preparation on a new tooth sample. The same procedure was used for CoCr and zirconia disc specimens. All of the bur surfaces were evaluated using roughness analysis. Then, horizontal tooth preparation surfaces were examined under both stereomicroscope and SEM. The depth maps of tooth surfaces were also obtained from digital stereomicroscopic images. The results were statistically analyzed using One-Way ANOVA, and the Tukey HSD post-hoc tests (${\alpha}=.05$). RESULTS. All of the groups were significantly different from the control group (P<.001). There was no significant difference between groups Z5 and Z10 (P=.928). Significant differences were found among groups T5, M5, and Z5 (P<.001). CONCLUSION. Diamond burs wear after multiple use and they should be changed after 5 teeth preparations at most. A diamond bur should not be used for teeth preparation after try-in procedures of metal or zirconia substructures.