• 제목/요약/키워드: metal lath

검색결과 25건 처리시간 0.023초

PP섬유 혼입 및 메탈라스 횡구속에 의한 고성능 콘크리트의 폭열방지에 관한 실험적 연구 (An Experimental Study on the Spatting Resistance of High Performance Concrete with PP Fiber Contents and Lateral Confinement by Metal-Lath)

  • 황인성;이백수;이병열;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.557-562
    • /
    • 2002
  • This paper describes the results of spalling by fire prevention of high performance concrete confining with metal-lath and containing PP fiber. According to test results, all the specimens without PP fiber shows entire failure after exposed to fire, while the other specimens confined with metal-lath has somewhat better spatting prevention performance than plain concrete specimens, which only show surface scale spatting combination of PP fiber with confinement of metal-lath leads to favorable spatting resistance. As PP fiber contents and thickness of metal-lath which is confined at concrete specimens increase, residual strength after exposed to fire shows to be increased.

  • PDF

화재시 횡구속재 변화에 따른 고성능 콘크리트의 폭열방지성능에 관한 기초적 연구 (A Fundamental Study on the Performance of Spalling Resistance of High Performance Concrete with Material of Lateral Confinement Subjected to Fire)

  • 배정렬;황인성;홍상희;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.47-50
    • /
    • 2002
  • This paper presents the results of fire resistance properties of high performance concrete varying with fiber kinds and the size of metal lath in order to verify the validities of fiber on the spatting resistance by fire. Metal lath, glass fiber and carbon fiber are used to confine the concrete. According to test results, plain concrete without lateral confinement and confined concrete with glass fiber and carbon fiber show entire failure after exposed to fire, while confined concrete with metal lath take place in the form of slight surface spatting by fire, which has favorable spatting resistance of concrete. As for the effect of the size of metal lath, when the size of metal lath is more than 1.2mm of thickness, the residual strength of concrete exposed to fire maintains more than 80% of its original strength. However, glass fiber and carbon fiber does not perform desirable spatting resistance by fire due to loss of lateral confinement of fiber exposed to fire caused by melting of fiber and reducing bond strength between concrete and fiber.

  • PDF

횡구속 재료변화에 따른 고성능 콘크리트의 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Properties of High Performance Concrete with Material for Lateral Confinement)

  • 김은호;정덕우;홍상희;윤기원;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.563-568
    • /
    • 2002
  • This paper is a fundamental study on the mechanical properties of the high performance concrete confined with metal lath, glass and carbon fiber laterally. According to the results, it shows that the compressive strength increases by 9%, 8% and 6% in metal lath carbon fiber and glass fiber in case of W/B 30% respectively. In case of W/B 30% and 40%, flecxural strength shows largely in order of carbon fiber, metal lath, glass fiber. In strain-stress curve with the kinds of material for lateral confinement, while brittleness failure occurs in plain concrete just after maximum load, it is improved in some degree in confined concrete due to increase of the strain by increase of toughness. But, elastic modulus shows the similar tendency between confined concrete and plain concrete. Length change ratio by drying shrinkage shows little a bit in order of carbon fiber, glass fiber and metal lath due to confinement.

  • PDF

횡구속 방법에 따른 고성능 RC 기둥 콘크리트의 내화특성 (Properties of Fire Endurance of High Performance RC Column with Laterral Confinement Method)

  • 황인성;김기훈;배연기;이보형;이재삼;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.553-556
    • /
    • 2004
  • This paper is to investigate the spalling and fire endurance of high performance RC column member with PP fiber and lateral confinement of metal lath and non fire resistance removal type form. According to test results, combination of PP fiber and metal lath as well as use fire resistance non removal type form had favorable fire resistance by discharging internal vapour pressure and lateral confining. After fire endurance test, compressive strength decreased markedly caused by internal expansion pressure and crack. Residual strength of plain concrete was decreased to $22\%$. The use of PP fiber and lateral confinement of metal lath and non removal type form enhanced the residual strength above $40\%$. Especially, the combination of $0.1\%$ of PP fiber and lateral confinement with the level of 2.3T exhibited more than $51\%$ of residual strength. Therefore, to improve fire endurance and spalling resistance, the combination of $0.1\%$ of PP fiber and metal lath with 2.3T can be the proper measure.

  • PDF

콘크리트 이어붓기 시공에 있어 차단성에 관한 실험적 연구 (An Experimental Study on the Blocking Performance Considering Construction Joint of Placement)

  • 김은호;정덕우;한민철;류현기;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.257-260
    • /
    • 2002
  • This study is intended is to analyze the blocking performance with variation of the gap of bar and kinds of metal lath for construction joint when placing concrete. According to the results, passing ratio of concrete increases with increase of vibrating time. In the case of W/C 50%, when blocking concrete with bar of D10 and D20 which the gap of bar is below 200mm, or metal lath, passing ratio of concrete is below 10%, so blocking performance is favorable. In the case of W/B 30%, while concrete does not flow out without vibration at slump 21mm, concrete flows out at some degree before vibration at slump flow 65mm and then, as 5 seconds passes after first vibration, final passing ratio shows about 85~90%. When blocking concrete by bar D10 of the gap 20mm, bar D20 of the gap 10mm and metal lath, it is thought that concrete can be blocked effectively because final passing ratio is below 10%.

  • PDF

횡구속재의 종류에 따른 고강도콘크리트 기둥의 내력 및 연성에 관한 연구 (A Study on the Behavior of High-Strength Concrete Columns with Variable Lateral Confinement)

  • 임정은;김은호;정덕우;윤승조;김성수;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.487-492
    • /
    • 2003
  • High-strength concrete(HSC) is a new construction material with enormous potential. Structures using high-strength concrete are to be coming more and more popular. But high-strength reinforced concrete columns show brittle behavior. It, therefore, is necessary to improve the ductility of HSC members. The purpose of this study is to investigate the ductility and strength of high-strength columns with variable lateral confinement under concentric axial load. Five HSC columns with compressive strength 68㎫ are designed with variable lateral confinements such as carbon fiber sheet(CFS), glass fiber sheet(GFS), and metal lath. Test results indicate that specimen confined by CFS show 11% higher maximum strength, 2.74 times ductility than A specimen using hoop. On comparing with the specimen A and B confined metal lath instead of hoop, strength decrease of 3%, and ductility increase of 1.21 times were observed.

  • PDF

횡구속재 변화에 따른 고성능 콘크리트의 역학적 특성 (Mechanical Properties of High Performance Concrete with Material for Lateral Confinement)

  • 한천구;정덕우;김은호
    • 콘크리트학회논문집
    • /
    • 제15권1호
    • /
    • pp.110-116
    • /
    • 2003
  • 근년, 콘크리트구조물이 고층화, 대형화됨에 따라 고강도, 고유동, 고내구성인 고성능 콘크리트의 수요가 많아지고 있다. 이러한 고성능 콘크리트는 보통콘크리트에 비하여 압축강도가 크고, 시공성 및 내구성이 우수한 것이 장점이지만, 보통강도 콘크리트에 비하여 파괴형태가 취성적인 것이 단점으로 제시되고 있다. 따라서, 본 연구는 W/B 30% 및 40%에서 메탈라스, 유리섬유 및 탄소섬유로 횡구속된 고성능 콘크리트의 역학적 특성을 분석하여 압축강도 및 인성개량방법을 제안하고자 하였다. 연구결과 압축강도는 횡구속재의 횡구속력의 증대에 기인하여 메탈라스, 탄소섬유 및 유리섬유의 순으로 증가하였다. 또한, 횡구속재 변화에 따른 응력-변형도곡선에서 플레인의 경우는 최대하중 이후 취성파괴로 나타난 반면, 횡구속된 경우로, 특히 메탈라스로 횡구속하였을 때에는 인성증가로 변형율이 증가하여 어느 정도 취성이 개량됨을 알 수 있었다. 탄성계수는 보강하지 않은 콘크리트와 비교하여 약간 큰 값으로 압축강도의 경향과 비슷한 양상이었다.

라스와 모르타르를 이용한 데크의 휨거동에 관한 실험적 연구 (An Experimental Study on the Flexural Behavior of Deck Plates with Metal Lath and Mortar)

  • 김성배;김성진;서동민;김상섭
    • 콘크리트학회논문집
    • /
    • 제20권1호
    • /
    • pp.117-125
    • /
    • 2008
  • 국내 건설 산업 분야에서는 건설 전문인력의 부족과 건설비용의 상승으로 데크플레이트의 사용이 증가하고 있다. 그러나 최근 지하 주차장과 같은 지하구조물에서 얇은 아연도금 강판으로 제작된 데크플레이트를 사용할 경우 사용연한에 따른 녹발생, 누수에 대한 유지보수비 증가 등 여러 가지 문제점이 지적되고 있다. 이러한 문제점을 해결하기 위하여 아연도금강판 대신 라스와 모르타르를 사용한 데크플레이트를 개발하였다. 본 연구에서는 새로 개발된 데크플레이트에 대하여 시공하중과 사용하중을 적용할 경우의 휨 성능을 평가하였다. 주요 변수로는 트러스의 형태, 상하 주근의 직경, 슬래브의 두께 등이다.

모르터와 메탈라스로 제작된 트러스형 테크플레이트의 구조적 성능 (Structural Performance of Trussed Bar Deck Plates of Metal Lath with Mortar)

  • 서동민;김성배;이창남;김상섭;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.41-44
    • /
    • 2006
  • Increase in use of deck plates is accelerated by a manpower shortage and the high cost of construction. Some of problems including fire resistance, waterproof, and low corrosion can be solved by development of new deck plates. This paper evaluates the structural performance of the LAMO Deck which metal laths instead of galvanized steel sheet is covered by mortar.

  • PDF

화재 피해를 입은 고강도 콘크리트 기둥의 보수공법 변화에 따른 내화특성 (Fire Resistance of Repaired High Strength Concrete Column Damaged by Fire)

  • 박천진;백대현;인기호;여인환;민병렬;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.113-116
    • /
    • 2009
  • This study analyzed fire-resistant characteristics according to changes in repair methods of PFH mixed high-strength concrete roof structures having undergone fire damage. The results of the study are as follows. First, as a repulsive characteristics of structures, the remaining repulsion was shown to increase following fire-resistance tests according to increases in depth of coverings. The results of the relationship between depth of coverings and remaining repulsion rates following fire-proofing tests showed a high correlation. At a covering depth of 67.3mm, remaining repulsion rate was estimated to be 100%. For fire-resistant characteristics following repairs of structure, as for spalling, severe separation was shown in the case of general plaster while general plaster + Metal Lath showed overall superior spalling prevention. For internal structure temperatures, general plaster showed max temperatures of 705℃, average temperatures of 636℃ while general plaster + metal lath showed max temperature of 660℃ and average temperature of 520℃, demonstrating lower temperature distributions than use of only general plaster. In conclusion, after removing the covering of structures damaged due to high temperatures of fires within high-strength concrete installations, the use of fire-resistant mortars and applying metal laths on surfaces of general plaster will provide superior fire-resistance performance in the occurrence of a 2nd fire.