A Study on the Behavior of High-Strength Concrete Columns with Variable Lateral Confinement

횡구속재의 종류에 따른 고강도콘크리트 기둥의 내력 및 연성에 관한 연구

  • Published : 2003.05.01

Abstract

High-strength concrete(HSC) is a new construction material with enormous potential. Structures using high-strength concrete are to be coming more and more popular. But high-strength reinforced concrete columns show brittle behavior. It, therefore, is necessary to improve the ductility of HSC members. The purpose of this study is to investigate the ductility and strength of high-strength columns with variable lateral confinement under concentric axial load. Five HSC columns with compressive strength 68㎫ are designed with variable lateral confinements such as carbon fiber sheet(CFS), glass fiber sheet(GFS), and metal lath. Test results indicate that specimen confined by CFS show 11% higher maximum strength, 2.74 times ductility than A specimen using hoop. On comparing with the specimen A and B confined metal lath instead of hoop, strength decrease of 3%, and ductility increase of 1.21 times were observed.

Keywords