• 제목/요약/키워드: medical robotics

검색결과 184건 처리시간 0.035초

IMPLEMENTATION OF THE MOXIBUSTION CAUTERIZER FOR PROSTATISM

  • Jo, Bong-Kwan;Bae, Jong-Il;Kwon, Sung-Yeol;Woo, Kyung-Il;Kim, Jong-Kyung;Lee, Dong-Cheol;Kim, Do;Ko, Young-Kyu;Jang, Sang-Youl;Jo, Bong-Jo;Koo, Ja-Sung;Lee, Dong-Young;Lee, Ho-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1895-1896
    • /
    • 2004
  • The conventional direct and indirect moxibustion therapies for prostatism treatment could not been applied to the acupuncture point of CV 1( Conception Vessel Meridian 1) because of its boring body region. In order to get rid of these problems we have suggested the moxa-pad cauterizer especially for prostatism. We have implemented the moxa-pad moxibustion cauterizer especially for the prostatism. The experimental demonstrations have been made by the stimulating the spots which are CV-1(Conception Vessel Meridian 1), B-28(Bladder Meridian 28), and CV-3(Conception Vessel Meridian 3) acupuncture points. And stimulating time was one hour with moxa-pad cauterizer.

  • PDF

다빈치 로봇을 이용한 포트 접근에 의한 심방중격 결손 폐쇄 수술 (Completely Port-Accessed Atrial Septal Defect Patch Closure Using the da Vinci System)

  • 김관식;이재원;정성호;김준범;정종필
    • Journal of Chest Surgery
    • /
    • 제43권4호
    • /
    • pp.409-412
    • /
    • 2010
  • 이차공형 심방 중격 결손 환자에서 다빈치 로봇을 이용하여 8∼12 mm 크기의 포트만을 이용한 심방 중격 결손 폐쇄술 다섯 예를 경험하여 문헌 고찰과 함께 보고하는 바이다.

AESOP을 이용한 좌측 최소개흉술하 동맥하형 심실중격 결손증 교정술 - 1예 보고 - (Repair of the Subarterial Type of VSD via a Left Minithoracotomy with using AESOP - A case report -)

  • 문덕환;이재원;조현진;제형곤;정성호;주석중;송현;정철현
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.630-632
    • /
    • 2008
  • AESOP (Automated Endoscope System for Optimal Positioning)을 이용한 최소 침습적 심장 수술은 고식적인 정중흉골 절개술을 이용한 심장 수술에 비하여 수술 상처가 작고, 수술 후 환자의 회복이 빠르며, 입원 기간을 단축시키는 등의 장점이 알려져 있다. 저자들은 26세 여자 환자에서 좌측 최소 개흉술을 이용한 동맥하형 심실중격 결손증의 교정수술을 성공적으로 시행하였기에 문헌고찰과 함께 보고하는 바이다.

An Automatic Control System of the Blood Pressure of Patients Under Surgical Operation

  • Furutani, Eiko;Araki, Mituhiko;Kan, Shugen;Aung, Tun;Onodera, Hisashi;Imamura, Masayuki;Shirakami, Gotaro;Maetani, Shunzo
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권1호
    • /
    • pp.39-54
    • /
    • 2004
  • We developed an automatic blood pressure control system to maintain the blood pressure of patients at a substantially low level during a surgical operation. The developed system discharges two functions, continuous feedback control of the mean arterial pressure (MAP) by a state-predictive servo controller and risk control based on the inference by fuzzy-like logics and rules using measured data. Twenty-eight clinical applications were made beginning in November 1995, and the effects of the automatic blood pressure control on the operation time and on bleeding were assessed affirmatively by means of Wilcoxon testing. This paper essentially reports the engineering details of the control system.

Active Contour Model Based Object Contour Detection Using Genetic Algorithm with Wavelet Based Image Preprocessing

  • Mun, Kyeong-Jun;Kang, Hyeon-Tae;Lee, Hwa-Seok;Yoon, Yoo-Sool;Lee, Chang-Moon;Park, June-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권1호
    • /
    • pp.100-106
    • /
    • 2004
  • In this paper, we present a novel, rapid approach for the detection of brain tumors and deformity boundaries in medical images using a genetic algorithm with wavelet based preprocessing. The contour detection problem is formulated as an optimization process that seeks the contour of the object in a manner of minimizing an energy function based on an active contour model. The brain tumor segmentation contour, however, cannot be detected in case that a higher gradient intensity exists other than the interested brain tumor and deformities. Our method for discerning brain tumors and deformities from unwanted adjacent tissues is proposed. The proposed method can be used in medical image analysis because the exact contour of the brain tumor and deformities is followed by precise diagnosis of the deformities.

A New Instrument for Early Detection of Alzheimer's Disease

  • Muraoka, Tetsuya;Nagata, Tomohiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2362-2366
    • /
    • 2003
  • The paper describes a new instrument for early detection of Alzheimer's disease. A new instrument for early detection of Alzheimer's disease is constructed on both the questionnaire for the investigation of living environment, and the lists for the functional tests of the sense, the physiology, and the left and right brains. When the medical doctor has made a diagnosis of Alzheimer's disease, the demented patient does not recover the indication adding available treatments. Then, the indication of a patient only takes a turn for the worse. For the demented patient can be kept his/her life style, Alzheimer's disease can make an early detection using a new instrument before a diagnosis of the dementia. And the indication of a demented patient can be delayed by the available medical treatments.

  • PDF

Application of Control Theory in Modelling Cancer Chemotherapy

  • Ledzewicz, Urszula;Schattler, Heinz
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.330-335
    • /
    • 2004
  • Phase specific models for cancer chemotherapy are described as optimal control problems. We review earlier results on scheduling optimal therapies when the controls represent the effectiveness of chemotherapeutic agents, or, equivalently, when the simplifying assumption is made that drugs act instantaneously. In this paper we discuss how to incorporate more realistic medical aspects which hitherto have been neglected in the models. They include pharmacokinetic equations (PK) which model the drug's plasma concentration and various pharmacodynamic models (PD) which describe the effect the concentrations have on cells. We also briefly discuss the important medical issue of drug resistance.

  • PDF

Controlled Inquiry Rates of Clinical Interviews in Telehomecare

  • Moskowitz, Samuel E.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1945-1950
    • /
    • 2003
  • Conceived to acquire personal information for an electronic medical record, the clinical interview contains probing questions. The number and type of inquiries are assumed to fulfill medical protocols, and therefore are deemed essential for treatment - but the rate can and should be controlled. High rates of inquiry merely intimidate the patient and affect replies. The purpose of this paper is to mathematically formulate permissible rates of clinical interviews held during telehomecare virtual visits and designed to avoid patient anxiety. Mental stress is derived as a function of the weight of importance assigned by the patient, virtual visit duration, and the rate of questioning in the direction of greater sensitivity. Two operations are of interest: Collecting and recording information by the provider, and maintaining synchrony of questions and answers by the patient. The Lorentz transformation yields the patient’s view of the operational rates. Conservation of information momentum is postulated and applied before and after replies are recorded. It is shown that the weight of importance designated by the patient to collecting and recording personal information is driven by a singularity that depends on the rate of questioning. The findings should serve as a guideline in interviewer training programs.

  • PDF

Effect of Cellular Phone on Fetal Heart Rate Patterns

  • Jafarabadi, Mina;Jafarabadi, Ladan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.181-184
    • /
    • 2004
  • There are reports showing that electromagnetic fields (EMFs) emitted at non-thermal levels may be associated with biological alterations in target cells. In this study it is objected to assess the potential influences of EMFs produced by cellular phones on fetal heart rate. Non Stress Test (NST) is a widely used method of fetal monitoring and assessing fetal health and well-being. Sixty volunteers with uncomplicated term pregnancies were studied by a Spacelabs AM-67 Doppler ultrasound monitor. Fetal Heart Rate recordings were obtained while there were no Cellular Phone around for 10 minutes. Afterwards, all patients were exposed to EMFs for 10 minutes. NST was performed while they were holding the CP on stand-by mode and then on dialing mode, each for 5 minutes. The recordings were analyzed with respect to baseline heart rate, accelerations and decelerations. The Wilcoxon matched-pairs signed-ranks test was used to compare these variables. The results indicate that EMFs emitted by CP do not cause any demonstrable effects on baseline FHR, acceleration or deceleration.

  • PDF

의료기기용 고속 BLDC 전동기의 특성해석 (Characteristics Analysis of high speed BLDC motor for Medical instruments)

  • 서영택;김형길;남상석;김철호;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.9-12
    • /
    • 2003
  • Brushless do motors have been replacing brush type motors in machine tool and robotics applications over the last number of years This Paper deals with the design and application of the slot-less permanent magnet synchronous motor (PMSM). The slot-less PMSM eliminates rotational cogging torque due to permanent magnet preferred positions decreases core loss and thus increases efficiency, provides excellent torque-to-volume and power-to-volume ratios, and has a linear current versus torque relation. The PMSM with slot-less stator is designed and manufactured, which will be used for high speed and high efficiency application such a medical instruments.

  • PDF