• Title/Summary/Keyword: medical image processing

Search Result 626, Processing Time 0.028 seconds

Image Discriminal Analysis for Detecting a Esophagitis (식도염 진단을 위한 영상 판별분석)

  • Seo K. W.;Lee C. W.;Kim W.;Lee S. Y.;Lee D. W.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.545-550
    • /
    • 2004
  • An Image processing algorithm was developed and tested to detect abnormal parts, such as esophagitis, with the information on the color and the texture in a digital clinic endoscopic image by using discriminal analysis. In order to develope the algorithm, the critical parameters from many parameters were found to distinguish between normal and abnormal part in the various images. The Inflammation and ulceration which are very important diagnostic indexes were detected by the algorithm. The algorithm proved to a reliable program for detecting abnormal parts with 20 images. A success rate was 92.8% and 92.4% in the calibration stage and the validation stage by using the algorithm with discriminal analysis.

A Study on Modified Switching Filter Using Region Segmentation (영역 분할을 이용한 변형된 스위칭 필터에 관한 연구)

  • Kwon, Se-ik;Kim, Nam-ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1284-1289
    • /
    • 2016
  • Recently, digital image processing is applied a lot to the broadcasting, communication, computer graphic, and medical sectors. It generates noise when data is transmitted. There are many kinds of noises that add to the image such as salt and pepper noise, AWGN, and complex noise. Thus, this study divides the corrupted image into four4 areas and estimates the types of noises each pixel, and this study suggested a switching filter that separates the estimated into salt and pepper noise and AWGN. In the case that center pixel of local mask is corrupted by salt and pepper noise, it used a histogram probability weighting of subdivided area. Also, in case that it is corrupted by AWGN, algorithm that is applied to with different weights given for the distribution of each area with using subdivided area's distribution was suggested. For an objective comparison and conclusion, this study used PSNR and compared to existing methods.

Region-of-Interest Detection using the Energy from Vocal Fold Image (성대 영상에서 에너지를 이용한 관심 영역 추출)

  • Kim, Eom-Jun;Sung, Mee-Young
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.804-814
    • /
    • 2000
  • In this paper, we propose an effective method to detect the regions of interests in the Videostrobokymography System. Videostrobokymography system is a medical image processing system for extracting automatically the diagnosis parameters from the irregular vibratory movements of the vocal fold. We detect the regions of interests through three steps. In the first step, we remove the noise in the input image and we find the minimum energy value in each frame. In the second step, we computed the edge by everage value for the one line. In the third step, the regions of interests can be extracted by using the Merge Algorithm which uses the variance of luminance as the feature points. We experimented this method for the vocal fold images of nineteen patients. In consequence, the regions of interests are detected in most vocal fold images. The method proposed in this study is efficient enough to extract the region of interests in the vocal fold images with the frame rate of 40 frames/second and the resolution of 200${\times}$280 pixels.

  • PDF

Influence of Job Satisfaction in Emergency Medical Technician within Hospital upon Organizational Commitment (병원 내 응급구조사의 직무만족도가 조직몰입에 미치는 영향)

  • Park, Sang-Sub;Park, Jae-Seong;Park, Dae-Sung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.2
    • /
    • pp.99-108
    • /
    • 2009
  • Purpose : The purpose of this study is to offer basic data in arranging the improved working environment to Emergency Medical Technicians, by analyzing the influence of job satisfaction in Emergency Medical Technician within hospital upon organizational commitment. Method : This study was carried out targeting 203 Emergency Medical Technicians who are working at hospitals in B Metropolitan City, U Metropolitan City, D Metropolitan City, an d G Province. The data collection was performed from April 1, 2009 to June 10. The statistical processing was used a program of SPSS WIN 12.0 Version. The statistical significance was set to p<.05. Results : 1. In the descriptive statistics of the job satisfaction and the organizational commitment. the whole average for job satisfaction was 3.06 points. The whole average for organizational commitment was 3.05 points. 2. In the difference between job satisfaction and organizational commitment, the group for job satisfaction was indicated to be statistically significant in job-choice motive(F=2.710, p<.05) and turnover propensity(t=.662, p<.001). The group for organizational commitment was indicated to be statistically significant in working department(F=2.871, p<.05), job-choice motive(F=2.944, p<.05), turnover propensity(t=.903, p<.001), and turnover reason(F=3.415, p<.01). 3. In the correlation between job satisfaction and organizational commitment, the job satisfaction showed positive correlation(r=.736, p<.01) with organizational commitment. 4. As for the influence of job-satisfaction factor upon organizational commitment, salary(${\beta}$=.162, t=2.739, p<.01), autonomy(${\beta}$=.372, t=4.633, p<.001), working environment(${\beta}$=.139, t=1.968, p<.05), and organizational needs(${\beta}$=.172, t=2.291, p<.05) were indicated to have significant effect on organizational commitment. Conclusion : The institutional arrangement is considered to be likely to be necessarily made highly for improving social image and enhancing salary and working environment so that Emergency Medical Technician within hospital can be enhanced job satisfaction and organizational commitment.

  • PDF

An Effective Extraction Algorithm of Pulmonary Regions Using Intensity-level Maps in Chest X-ray Images (흉부 X-ray 영상에서의 명암 레벨지도를 이용한 효과적인 폐 영역 추출 알고리즘)

  • Jang, Geun-Ho;Park, Ho-Hyun;Lee, Seok-Lyong;Kim, Deok-Hwan;Lim, Myung-Kwan
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1062-1075
    • /
    • 2010
  • In the medical image application the difference of intensity is widely used for the image segmentation and feature extraction, and a well known method is the threshold technique that determines a threshold value and generates a binary image based on the threshold. A frequently-used threshold technique is the Otsu algorithm that provides efficient processing and effective selection criterion for choosing the threshold value. However, we cannot get good segmentation results by applying the Otsu algorithm to chest X-ray images. It is because there are various organic structures around lung regions such as ribs and blood vessels, causing unclear distribution of intensity levels. To overcome the ambiguity, we propose in this paper an effective algorithm to extract pulmonary regions that utilizes the Otsu algorithm after removing the background of an X-ray image, constructs intensity-level maps, and uses them for segmenting the X-ray image. To verify the effectiveness of our method, we compared it with the existing 1-dimensional and 2-dimensional Otsu algorithms, and also the results by expert's naked eyes. The experimental result showed that our method achieved the more accurate extraction of pulmonary regions compared to the Otsu methods and showed the similar result as the naked eye's one.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

A Study on Treatment Target Position Verification by using Electronic Portal Imaging Device & Fractionated Stereotatic Radiotherapy (EPID와 FSRT를 이용한 치료표적위치 검증에 관한 연구)

  • Lee, Dong-Hoon;Kwon, Jang-Woo;Park, Seung-Woo;Kim, Yoon-Jong;Lee, Dong-Han;Ji, Young-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.44-51
    • /
    • 2009
  • It is very important to verify generated setup errors in cancer therapy by using a high energy radiation and to perform the precise radiation therapy. Specially, the verification of treatment position is very crucial in special therapies like fractionated stereotatic radiotherapy (FSRT). The FSRT uses normally high-dose, small field size for treating small intracranial lesions. To estimate the developed FSRT system, the isocenter accuracy of gantry, couch and collimator were performed and a total of inaccuracy was less than ${\pm}1mm$. Precise beam targeting is crucial when using high-dose, small field size FSRT for treating small intracranial lesions. The EPID image of the 3mm lead ball mounted on the isocenter with a 25mm collimator cone was acquired and detected to the extent of one pixel (0.76mm) after comparing the difference between the center of a 25mm collimator cone and a 3 mm ball after processing the EPID image. In this paper, the radiation treatment efficiency can be improved by performing precise radiation therapy with a developed video based EPID and FSRT at near real time

A Construction of the Multistep Optimal Three-Dimensional Finite Elements for the Mandible Structure Analysis (하악 구조체 분석을 위한 다단계 최적 3 차원 유한 요소 형성)

  • Lee, Hyeong-U;;Lee, Seong-Hwan;Kim, Chang-Heon;Kim, Tae-Yun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.7
    • /
    • pp.1906-1916
    • /
    • 1996
  • For the medical analysis of the three-dimensional structure such as the mandible, it is necessary to reconstruct the structure into the finite number of analyzable elements. The information of the three-dimensional structure can be obtained from the cross-sections of the magnetic resonance image (MRI). A region corresponding to the structure is extracted from the inner part of the cross- section. By the triangulation of the sampled cross-section image, two-dimensional finite elements are generated. Three-dimensional finite elements are constructed by matching the two dimensional finite elements each other in space. In this paper a construction method of the optimal three-dimensional finite elements has been suggested, which uses the adjacent information abstracted from the triangulated two-dimensional finite elements. The elements are classified into the identical property sets by using the adjacent information of the traingulated two-dimensional elements. After applying the multistep matching algorithm to the classified two-dimensional finite elements, the optimal three-dimensional finite elements can be construccted. By analyzing the constructed finite elements, it is possible to get much more useful medical information about the three-dimensional struture of mandible.

  • PDF

Analysis of Couch Sag Using Image Processing of MVCT Images in Tomotherapy (토모테라피에서 MVCT 영상을 이용한 환자 테이블의 처짐 정도의 분석)

  • Park, Ha Ryung;Kim, Yong Ho;Park, Dahl;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Bae, Jin Suk
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.106-111
    • /
    • 2015
  • In Tomotherapy the couch sags during the treatment due to the weight of the patient. In this study, we developed a simple method to obtain the amount of the sag and the pitch angle of the couch using the image processing technique of MVCT images in Tomotherapy. Using the method we evaluated the sag and pitch of couch for 22 head and neck patients and one craniospinal irradiation (CSI) patient. The sag and the average pitch angle of couch were 0.40~1.54 mm and $0.7^{\circ}$ for head and neck patients, respectively. For head and neck patients, the sag increased as the longitudinal length of the irradiation volume increased and the pitch angle showed no relationship with the longitudinal length. For the CSI patient the sag was 4.97 mm. Using the method the amount of the couch sag could be measured easily and the measured data could be useful in determination of margins considering the table sag error.