• Title/Summary/Keyword: medical image data

Search Result 1,020, Processing Time 0.023 seconds

Estimation of Unknown Projection DATA Based on the Bandwidth of Projection DATA

  • Kil-Houm Park
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 1994
  • In the case of the image reconstruction from unknown projection data such as imaging the object with opaque obstructions, conventional reconstruction algorithms may reconstruct a degraded image. In this paper, a new method for the estimation of the unknown projection data based on known projection data and the bandwidth of projection data is proposed. The proposed method successfully estimates the unknown projection data through iterative transformation between projection space and frequency space using the known projection data and the bandwidth of the projection data. Computer simulation shows that the proposed method significantly improves image quality and convergence behavior over conventional algorithms. In addition, the proposed method is successfully applied to ultrasound attenuation CT using a sponge phantom.

  • PDF

Body Weight and Body Image: A Risk Factor Analysis in Korea

  • Kim, Sang-Wook
    • Survey Research
    • /
    • v.12 no.3
    • /
    • pp.143-172
    • /
    • 2011
  • The relationship between body weight and body image, an objective and subjective measure of body shape, respectively, has long been a recurrent concern in the area of medical sociology and health-related studies. This concern stems from the argument and findings in the literature indicating that the two are not necessarily likely to be strongly correlated due mostly to the fact that one's own idea or conception about his/her body shape could be pretty different from one's actual shape. This study tries to empirically address the two issues based on the analysis of a national sample survey data in Korea: to what extent body weight and body image are correlated with or deviated from each other, on the one hand, and what factors help to account for the relationship between the two, on the other. The latest(2010) national sample data of KGSS(Korean General Social Survey) is used to evaluate the issues. Results of data analysis demonstrate that body weight and image have a moderate amount of correlation, and that the correlation tends to vary to a large extent depending on a few major socio-demographic and socio-economic characteristics. Most important, the risk factor analysis attempted in this study could identify several salient risk factors, which include gender, age, chronic diseases, smoking, physical exercises, and medical checkup. To be precise, those who may be best characterized as particularly risky to weight gains are females, who are in their 20's, who have chronic diseases, non-smokers, who exercise regularly, and who conduct medical checkups on a regular basis. To extrapolate, the findings suggest that the most typically risky kinds of individuals in Korea are "young women who care very much for their health." The findings are interpreted and discussed with suggesting a recommendation for further studies.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Brain Hologram Visualization for Diagnosis of Tumors using Graphic Imaging

  • Nam, Jenie;Kim, Young Jae;Lee, Seung Hyun;Kim, Kwang Gi
    • Journal of Multimedia Information System
    • /
    • v.3 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This research paper examines the usage of graphic imaging in Holographic Projections to further advance the medical field. It highlights the importance and necessity of this technology as well as avant-garde techniques applied in the process of displaying images in digital holography. This paper also discusses the different types of applications for holograms in society today. Different tools were utilized to transfer a set of a cancer patient's brain tumor data into data used to produce a 3D holographic image. This image was produced through the transfer of data from one program to another. Through the use of semi-automatic segmentation through the seed region method, we were able to create a 3D visualization from Computed Tomography (CT) data.

Study on the Present Gown of Oriental Medical Doctors in Korea (우리나라 현행 한의사 진료가운에 대한 조사연구)

  • 서옥경
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.3
    • /
    • pp.139-147
    • /
    • 2002
  • This study was carried out to survey the contentment of the oriental medical doctors to the present gown which they wear. The objects were the oriental medical doctors who work for the university hospitals and the private clinics. The subjects were mainly the evaluation of the relation to the image of oriental hospital and the gown, the evaluation of the present their gowns and the evaluation on the improvement of their gowns. The collected data were analysed by the frequency, cross-table and $\chi^2$ using SPSS program. The results showed that the oriental medical doctors who work for the university hospital evaluated the difference of the image more important than those who work for the private clinics. Also the former was more than the latter on the necessity of the difference in the gowns between the western and oriental medical doctors. The oriental doctors regarded the tradition as of great importance in the improvement of their gown. More than 70% of them wanted to separate their gown for the spring-summer from that for the autumn-winter.

Comparison and analysis of chest X-ray-based deep learning loss function performance (흉부 X-ray 기반 딥 러닝 손실함수 성능 비교·분석)

  • Seo, Jin-Beom;Cho, Young-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1046-1052
    • /
    • 2021
  • Artificial intelligence is being applied in various industrial fields to the development of the fourth industry and the construction of high-performance computing environments. In the medical field, deep learning learning such as cancer, COVID-19, and bone age measurement was performed using medical images such as X-Ray, MRI, and PET and clinical data. In addition, ICT medical fusion technology is being researched by applying smart medical devices, IoT devices and deep learning algorithms. Among these techniques, medical image-based deep learning learning requires accurate finding of medical image biomarkers, minimal loss rate and high accuracy. Therefore, in this paper, we would like to compare and analyze the performance of the Cross-Entropy function used in the image classification algorithm of the loss function that derives the loss rate in the chest X-Ray image-based deep learning learning process.

The Development of Image Processing System for Medical Robot Remote Application (의료용 로봇 원격 응용을 위한 영상처리 시스템 개발)

  • Kim, Joo Young;Kim, Joong Hyuk;Kim, Jung Chae;Kim, Kee Deog;Yoo, Sun K.
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.239-251
    • /
    • 2012
  • In this paper, web-base image processing system has been implemented for remote-controlled medical robot applications. The developed software system was hierarchically composed of diverse image processing and remote operation modules, and the hierarchical composition was satisfied the expandability to higher level application and the accessibility over the web. It can also support diverse file formats including DICOM, VRML, and CAD(STL) to display, transmit, store and share the processed images depending on application environment. Message-based data exchange, object-oriented module and open-source based software configuration will enable the dynamic combination associated with diverse remote medical application requirements.

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.

Image Quality of Amorphous Selenium DR system using MTF measurement (MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구)

  • Seok, Dae-Woo;Park, Ji-Koon;Choi, Jang-Yong;Nam, Sang-Hee;Kang, Shin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

Feasibility Study of CNN-based Super-Resolution Algorithm Applied to Low-Resolution CT Images

  • Doo Bin KIM;Mi Jo LEE;Joo Wan HONG
    • Korean Journal of Artificial Intelligence
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Recently, various techniques are being applied through the development of medical AI, and research has been conducted on the application of super-resolution AI models. In this study, evaluate the results of the application of the super-resolution AI model to brain CT as the basic data for future research. Acquiring CT images of the brain, algorithm for brain and bone windowing setting, and the resolution was downscaled to 5 types resolution image based on the original resolution image, and then upscaled to resolution to create an LR image and used for network input with the original imaging. The SRCNN model was applied to each of these images and analyzed using PSNR, SSIM, Loss. As a result of quantitative index analysis, the results were the best at 256×256, the brain and bone window setting PSNR were the same at 33.72, 35.2, and SSIM at 0.98 respectively, and the loss was 0.0004 and 0.0003, respectively, showing relatively excellent performance in the bone window setting CT image. The possibility of future studies aimed image quality and exposure dose is confirmed, and additional studies that need to be verified are also presented, which can be used as basic data for the above studies.