• Title/Summary/Keyword: medical direction methods

Search Result 414, Processing Time 0.031 seconds

A Clinical Review on the Transoral Approach to the Fractures of The Mandible (구내 접근법에 의한 하악골 골절 치료에 대한 임상적 고찰)

  • Park, Hyung-Sik;Kwon, Jun-Ho;Chung, Seong-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.79-86
    • /
    • 1989
  • The is a retrospective study on the transoral approach to open reduction of the Mandibular fractures. Our study was based on a series of 64 patients with mandibular fractures among 99 patients of facial bone fractures who had been treated by transoral approach with or without extraoral approach at Department of Oral and Maxillofacial Surgery, Yonsei Medical Center, Yonsei University from January 1981 to October 1988. We studied favorite sites of open reduction, fixation methods, results and prognosis related to transoral approaches of Mandibular fractures, and which compared with extraoral approaches. The results obtained are as follows : 1. The transoral open reduction was used more frequently in Mandibular fractures(64.6%) than Midfacial bone fractures(35.4%). Among 64 patients of mandibular fractures, 47 patients(73.4%) were treated only by transoral approach and others(26.6%) were treated by both trans- and extra-oral approach. Among 92 sites of mandibular fractures, 75 sites(81.5%) were treated by transoral approach and 17(18.5%) were treated by extraoral approach. 2. The most favorite site for transoral approach compared with extraoral approach was Symphysis(100%), and Angle(62.5%) was next in order of frequency on Mandibular fractures. 3. Direct Interosseous Wiring(DIW) was most commonly used for fixation(64.6%) and Miniplate osteosynthesis was used next in 28.1%. 4. Simple(39.1%) and Compound(52.2%) fractures were frequently indicated for transoral approach, however comminuted fractures were rarely indicated. 5. The direction of fracture lines on Angle of the mandible did not influence to determine whether transoral approach should be selected or not. However this area seemed to be more difficult to reduce exactly by transoral procedure than other areas because simultaneous superior and inferior fixation was applied predominantly on this area. 6. The success rate of reduction and fixation analyzed from us was more excellent in Direct Interosseous Wiring(29/53=54.7%) than in Rigid Internal Fixation(9/29=31.0%). But it might be depended upon various factors as like as sugeon's skill. 7. The postoperative complication due to transoral open reduction of mandible was not high(12.0%) and this rate was similar with other published reports.

  • PDF

Korean Standard Classification of Diseases of Early Postpartum Women in a Korean Medicine Hospital (일개 한방병원에 내원한 산욕초기 산모의 한국표준질병·사인분류 분석)

  • Kim, Pyung-Wha
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.32 no.1
    • /
    • pp.73-84
    • /
    • 2019
  • Objectives: The purpose of this study is to collect and analyze the KCD codes applied to the treatment of 27 postpartum women who had been treated with Korean traditional medicine in a Korean medicine hospital, so that this study may be used as a basic data for setting the direction of postpartum Korean medical treatment research. Methods: It was approved by the Institutional Review Board (IRB) of ${\bigcirc}{\bigcirc}$ University medical center (IRB approval number : WSOH IRB H1708-02-01). Twenty-seven postpartum women who had been treated at ${\bigcirc}{\bigcirc}$ University medical center were received outpatient treatment for two weeks (from September 27, 2017 to January 5, 2018), and the KCD codes applied to the mothers were collected after obtaining the consent. On the day of registration of the study, the fertility, obstetric history and high-risk pregnancies were identified through an interview. Results: 1. The mean age of the 27 subjects was $33.33{\pm}3.99\;years$ old. Among the subjects, 17 mothers (63.0%) were high-risk pregnancy and 10 mothers (37.0%) were normal. 2. Among the 22 major disease categories, 8 categories were used. M code (musculoskeletal system) was used 243 times (70.85%), followed by R code (unclassified symptom) of 51 times (14.87%) and U code (special purpose code) of 23 times (6.71%). 3. The most commonly used code among the ten frequently used codes was M25.57 (joint pain, ankle and foot), a total of 47 times. Of the remaining nine codes, except for R60.1 (systemic edema) and U68.4 (The deficiency of yang in Bi), all codes were M codes (musculoskeletal system). 4. The M code (musculoskeletal system) was the most used major disease category in high-risk group, a total of 159 times. But in specific categories, the most commonly used code was R60.1 (systemic edema), a total of 28 times. 5. In normal group, the M code (musculoskeletal system) was the most used major disease category, a total of 84 times. Also, in specific categories, the most commonly used code was M25.57 (joint pain, ankle and foot), total 29 times. 6. The U code, corresponding to 'the diagnosis of childbirth and other obstetrical medical use', was used 23 times (6.71%), O code three times (0.87%) and Z code two times (0.58%), which was less than 10% of the total number of codes used. Conclusion: When analyzing KCD codes related to Korean medicine treatment for postpartum diseases, it is important to select the KCD codes that reflect the actual clinical state.

A Comparative Law Study on the Professional Work of Nurses: Focusing on Legal Basis and Standardization (간호사의 전문적 업무에 대한 국가 간 비교법적 연구: 법적 근거와 업무 범위 표준화를 중심으로)

  • Jayoung You;Jiyong Park
    • The Korean Society of Law and Medicine
    • /
    • v.25 no.1
    • /
    • pp.117-148
    • /
    • 2024
  • This study attempted to examine the ambiguity of work from the legal, social perspective, and actual performance differences in domestic nursing work compared to foreign countries. We compared the historical background of nurses' expanded work through overseas situations, compare and analyze the legal basis for nurses' qualifications and work in each country, and what changes they have undergone to clarify their work. Through this, we would like to consider the current status of the absence of a legal basis for professional work of domestic nurses and seek a direction for the development of domestic medical care. This study applied the case study method as one of the comparative institutional research methods. Among OECD countries, developed countries such as the United States, Australia, and Japan were selected and compared among developed countries that are solving medical gaps using nurses. In the United States, Australia, Japan, and Korea, nurses' professional work has been created by changes in the medical environment due to an aging society, chronic diseases, and lack of doctors. We looked at the start of their professional work, the establishment of legal grounds, the timing of qualification recognition, the development of the credential system and scope of work. Foreign countries have legal grounds for their roles and tasks, but domestic countries are before legislation. The country still has not narrowed the gap between the position of the legislative and judicial branches and actual work, and the current status of the domestic healthcare system has been measured through overseas development cases.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

4-Dimensional dose evaluation using deformable image registration in respiratory gated radiotherapy for lung cancer (폐암의 호흡동조방사선치료 시 변형영상정합을 이용한 4차원 선량평가)

  • Um, Ki Cheon;Yoo, Soon Mi;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.83-95
    • /
    • 2018
  • Purpose : After planning the Respiratory Gated Radiotherapy for Lung cancer, the movement and volume change of sparing normal structures nearby target are not often considered during dose evaluation. This study carried out 4-D dose evaluation which reflects the movement of normal structures at certain phase of Respiratory Gated Radiotherapy, by using Deformable Image Registration that is well used for Adaptive Radiotherapy. Moreover, the study discussed the need of analysis and established some recommendations, regarding the normal structures's movement and volume change due to Patient's breathing pattern during evaluation of treatment plans. Materials and methods : The subjects were taken from 10 lung cancer patients who received Respiratory Gated Radiotherapy. Using Eclipse(Ver 13.6 Varian, USA), the structures seen in the top phase of CT image was equally set via Propagation or Segmentation Wizard menu, and the structure's movement and volume were analyzed by Center-to Center method. Also, image from each phase and the dose distribution were deformed into top phase CT image, for 4-dimensional dose evaluation, via VELOCITY Program. Also, Using $QUASAR^{TM}$ Phantom(Modus Medical Devices) and $GAFCHROMIC^{TM}$ EBT3 Film(Ashland, USA), verification carried out 4-D dose distribution for 4-D gamma pass rate. Result : The movement of the Inspiration and expiration phase was the most significant in axial direction of right lung, as $0.989{\pm}0.34cm$, and was the least significant in lateral direction of spinal cord, as -0.001 cm. The volume of right lung showed the greatest rate of change as 33.5 %. The maximal and minimal difference in PTV Conformity Index and Homogeneity Index between 3-dimensional dose evaluation and 4-dimensional dose evaluation, was 0.076, 0.021 and 0.011, 0.0 respectfully. The difference of 0.0045~2.76 % was determined in normal structures, using 4-D dose evaluation. 4-D gamma pass rate of every patients passed reference of 95 % gamma pass rate. Conclusion : PTV Conformity Index was more significant in all patients using 4-D dose evaluation, but no significant difference was observed between two dose evaluations for Homogeneity Index. 4-D dose distribution was shown more homogeneous dose compared to 3D dose distribution, by considering the movement from breathing which helps to fill out the PTV margin area. There was difference of 0.004~2.76 % in 4D evaluation of normal structure, and there was significant difference between two evaluation methods in all normal structures, except spinal cord. This study shows that normal structures could be underestimated by 3-D dose evaluation. Therefore, 4-D dose evaluation with Deformable Image Registration will be considered when the dose change is expected in normal structures due to patient's breathing pattern. 4-D dose evaluation with Deformable Image Registration is considered to be a more realistic dose evaluation method by reflecting the movement of normal structures from patient's breathing pattern.

  • PDF

Dose Comparison of Treatment Plans Using Different Ir-192 Sources and Treatment Planning Systems for Intracavitary HDR Brachytherapy (고선량률 강내 근접치료에 사용되는 Ir-192 선원과 치료계획 시스템간의 계산선량 비교)

  • Park, Dong-Wook;Kim, Young-Seok;Park, Sung-Ho;Choi, Eun-Kyung;Kim, Jong-Hoon;Lee, Sang-Wook;Song, Si-Yeol;Ahn, Seung-Do;Noh, Young-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • For HDR intracavitary brachytherapy with ovoids and a tandem, we compared the dose discrepancy of treatment plans using two different Ir-192 sources (microSelectron, Varian) and generated on two different treatment planning systems (PLATO, BrachyVision). The treatment plans of ten patient treated from Oct. 2007 to Jan. 2008 were selected for these comparisons. For the comparison of dose calculation using different sources, the average discrepancies were $-0.91{\pm}0.09%$, $-0.27{\pm}0.07%$, $0.22{\pm}0.39%$, and $0.88{\pm}0.37%$ in total treatment time and at B-point and ICRU bladder and rectum reference point, respectively. Comparing the two systems, the average dose discrepancies between treatment planning programs were $-0.22{\pm}0.42%$, $-0.25{\pm}0.29%$, $-0.23{\pm}0.63%$, and $-0.17{\pm}0.76%$, and the average dose discrepancies between positioning methods (PLATO with film and BrachyVision with digitial image) were $-0.61{\pm}0.59%$, $-0.77{\pm}0.45%$, $-0.72{\pm}1.70%$, and $0.35{\pm}2.82%$ at A-point, B-point, and ICRU bladder and rectum reference points, respectively. The rectal dose discrepancies between two systems were reached 5.87%. The difference in the dwell position expected by each TPS are mainly affected by the differences in the positioning method in TPSs and have an effect on dose calculations of rectal and bladder located in AP direction.

  • PDF

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

An Analytic Case Study on the Management of an Upper-level General Hospital(2010-2012)

  • Park, Hyun-Suk;Lee, Jung-Min;Baek, Hong-Suck;Lee, Jun-Ho;Park, Sang-Sub
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.1
    • /
    • pp.1-16
    • /
    • 2014
  • Purpose. For a more efficient hospital management, this study aims to provide basic data so that the hospital management and staff in charge of hospital administration may systematically classify and collect hospital information, by analyzing the ordinary characters of an upper-level general hospital system and its common-type balance sheet, common-type profit and loss statement and financial ratio. Methods. By using information about an upper-level general hospital in C Province, provided by Alio(www.alio.go.kr), a public organization information provision site, Health Insurance Review & Assessment Service(www.hira.or.kr) and Ministry of Health and Welfare(www.mw.go.kr), this study analyzed 3 year's data from 2010 to 2012 and provided basic data by analyzing the ordinary characters of an upper-level general hospital system, and its common-type balance sheet, common-type profit and loss statement and financial ratio. Results. After analyzing the ordinary characters, common-type balance sheet, common-type proft and loss statement and financial ration of this general hospital, based on the 2010 to 2012 data, this study came to the following conclusions. Firstly, out of all the 1,069 hospital staff, there were 272 doctors working for 24 medical departments, out of whom the majority was 33 physicians. Most of the nurses were third-class ones, and about 2,000 outpatients and 600 inpatients on average were treated per day. Secondly, as a result of analyzing the common-type balance sheet, this study discovered that intangible assets out of fixed assets accounted for 41%, the majority, out of which usable and profitable donation asset buildings were of great importance, and the liquid assets increased more in 2012 than 2011. In the financial structure, the ratio of liquid liabilities was over 50% out of all the liabilities in 2012, and the ratio of purchase payables was high as well. The ratio of fixed liabilities reached up to 40%, out of which the retirement benefit appropriation fund was quite high. The capital was over 80%, but the surplus was in a deficit state. Compared to the capital, the ratio of total liabilities was about 90%, which indicates the financial structure of this general hospital was vulnerable. Thirdly, as a result of analyzing the common-type profit and loss statement, this study found out that the medical profits from inpatients were higher than profits from outpatients. The material cost was related to the medical quality of this general hospital, and it was as high as 30% out of the total costs and was about 45% of the labor cost. This general hospital showed 10% in the ratio of non-medical profits, and it seemed because of government subsidies. The ratios of medical profits and current net income were gradually changing for the better in 2012, compared to 2011. Lastly, as a result of analyzing the financial ratio, it was found that the liquidity ratio kept decreasing, from 110.7% in 2010 and 102.0% in 2011 to 77.2% in 2012. Besides, it was analyzed that the liquidity ratio and the net working capital ratio greatly decreased, while the quick ratio and the liquid ratio kept decreasing. Conclusions. 1. It is necessary to take the risk management into more consideration, and particularly, it is needed to differentiate and manage the levels of risk in detail. 2. By considering the fact that investments into hospital infrastructures were mostly based on liabilities, it is needed to deal with the scale of losses when evaluating risks. 3. By reflecting the character that investments into hospital infrastructures were based on liabilities, it is necessary to consider the ratio of ordinary profits as well as the ratio of operating profits to sales, and it is also important to consider sales productivity factors, such as the sales amount per a sickbed, by comparing them with other hospitals. As for limitations of this study, there may be some problems in terms of data interpretation because of the lack of information about the number of inpatients and the number of outpatients per year, which are needed for the break-even point analysis. Besides, to suggest a direction for the improvement of hospital management through analyses, non-financial factors should be reflected, such as the trend of economy, medical policies, and politic backgrounds. However, this study only focused on the common-type balance sheet, common-type profit and loss statement and financial ratio, so this study is actually limited to generalizing all the factors by analyzing public data only.

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

The Relationship Between Korean Handwriting Skill and Visual Fixation (비장애 아동의 한글쓰기 숙련도와 시선고정 간의 관련성)

  • Hong, Mi Young;Lee, Cho Hee;Kim, Eunbin;Lee, Onseok;Kim, Eun Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Objective : This paper aimed to measure the relationship between the performance of Korean handwriting and visual fixation for children. Methods : Twenty-one typically developing children aged 7 to 9 years participated in the study. The children performed Korean handwriting task wearing Tobii Pro Glasses 2. The Korean handwriting task consisted of 10 words from elementary school textbooks. The handwriting skill was measured by the coefficient variation of the letter size and the fixation cound and duration. Correlation analysis was performed to investigate the relation between visual fixation and the coefficient variation of the letter size. Results : The results showed that the visual fixation per second was positively correlated with Korean handwriting vertical size coefficient variation, indicating that the more consistent the vertical size of the letter, the smaller the fixation count per second. Conclusion : The results suggested a relation between the performance of Korean handwriting and visual fixation in typically developing children. This study is the first attempt to measure eye movement during the Korean handwriting process, and suggests a future direction for research on students' development in writing Korean.