• Title/Summary/Keyword: media power

Search Result 1,058, Processing Time 0.037 seconds

Optimum Power Calibration for LightScribe (라이트스크라이브(LightScribe) 미디어 라벨링(Labeling)을 위한 최적 기록 파워 조정)

  • Roh, Sang-Chul;Chung, Ki-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1117-1118
    • /
    • 2008
  • The LightScribe Technology is for printing images on the label side of recordable media using CD laser diode. By implementing Optimum Labeling Power Calibration for LightScribe, Labeling Quality can be improved. This paper proposes a new laser power calibration method using RFSUM signal. This function is implemented based on GH22LP20 of LG Electronics.

  • PDF

QoS Routing for WiMedia-Based Wireless Mesh Networks (WiMedia 기반 무선 메쉬 네트워크에서 QoS를 고려한 경로 설정)

  • Park, Sung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.317-324
    • /
    • 2016
  • WiMedia provides the data rate of up to 1Gbps, but the transmission range is restricted to approximately 10 meters. When constructing a multi-hop WiMedia network to extend its coverage, conventional hop-based routing may not guarantee satisfactorily the required QoS. We propose two QoS routing techniques for the WiMedia-based wireless mesh network. The proopsed QoS routing reflects the characteristics of TDMA-based WiMedia MAC and develops QoS extensions separately for on-demand routing and table-driven routing. Through simulations, we identify that the QoS routing shows better performance than the hop-based routing. It also turns out that the QoS on-demand routing and the QoS table-driven routing show conflicting performance results depending on the transmission power.

A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit (콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구)

  • Lee, Kwang-Jeek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

Linkage control system design combined MCU (MCU 통합 연동 제어시스템 설계)

  • Ha, T.J.;Park, J.M.;Cho, K.O.
    • Smart Media Journal
    • /
    • v.1 no.1
    • /
    • pp.58-63
    • /
    • 2012
  • It is a superordinate concept to a network control system which optimally distributes the battery power to overall length parts through the linkage control drive and absorbs/integrates network diagnostics and overlapped functions with overall length control systems. This study is to develop a system that maximize the battery power and motor effectiveness by controlling motor battery controlling module with common MCU Integration linkage controlling system, and to develop S/W and H/W that can be controlled by linked with each controlling module in CAN method through using Autosar's standardized software.

  • PDF

Thermal Hydraulic Analysis Methodology for PWR Nuclear Power Plant Steam Generators (원전 가압경수로 증기발생기 열유동 해석법)

  • Choi, Seok-Ki;Nam, Ho-Yun;Kim, Eui-Kwang;Kim, Hyung-Nam;Jang, Ki-Sang;Hong, Sung-Yull
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.463-468
    • /
    • 2001
  • This paper presents the methodology for thermal hydraulic analysis of Pressurized Water Reactor (PWR) steam generators. Topics include porous media approach, governing equations, physical models and correlations for solid-to-fluid interaction and heat transfer and numerical solution scheme. Some details about the ATHOS3 code currently used widely for thermal hydraulic analysis of PWR steam generators in the industry are presented. The ATHOS3 code is applied to the thermal hydraulic analysis of steam generator in the Korea YGN 3&4 nuclear power plant and the computed results are presented.

  • PDF

A Heterogeneous Home Network Control System Using HNCP

  • Jeon, Joseph;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1598-1601
    • /
    • 2005
  • In this paper, a heterogeneous home network control system using HNCP is proposed and implemented. A power line and 802.15.4 are used as media for the system. Information about home environment gathered by sensors is transferred to a power line connected device through the 802.15.4. HNCP stimulate the home network based on the both media. Sensor device definition for the HNCP address and message set is proposed. TinyOS supports the HNCP stack on the wireless sensor board. The home network control system implemented with these techniques has a benefit of user friendly operation of home appliances based on the sensing data. Implementation and experiment shows validity of the system.

  • PDF

SNA to assess the Influence of Organization Members (Focusing on core members of North Korea)

  • Lee, Young-Seok;Yoon, Soungwoong;Lee, Sang-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.73-80
    • /
    • 2018
  • There are various organizations in modern society, in which people have direct and indirect relationships. Internal structure of these organizations can be analyzed by the relationships which are officially pressed on the media. However, this task will be difficult when the media information is strictly limited, though the necessity of analyzing organization structure remains. In this study, we try to estimate the influence of North Korea's core members by using PageRank centrality to supplement the limitation of previous SNA analysis methods. Experimental results show that we can show and predict NK's power shifts more efficiently.

A Semi-Markov Decision Process (SMDP) for Active State Control of A Heterogeneous Network

  • Yang, Janghoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.7
    • /
    • pp.3171-3191
    • /
    • 2016
  • Due to growing demand on wireless data traffic, a large number of different types of base stations (BSs) have been installed. However, space-time dependent wireless data traffic densities can result in a significant number of idle BSs, which implies the waste of power resources. To deal with this problem, we propose an active state control algorithm based on semi-Markov decision process (SMDP) for a heterogeneous network. A MDP in discrete time domain is formulated from continuous domain with some approximation. Suboptimal on-line learning algorithm with a random policy is proposed to solve the problem. We explicitly include coverage constraint so that active cells can provide the same signal to noise ratio (SNR) coverage with a targeted outage rate. Simulation results verify that the proposed algorithm properly controls the active state depending on traffic densities without increasing the number of handovers excessively while providing average user perceived rate (UPR) in a more power efficient way than a conventional algorithm.

Thermal conductivity properties of cement matrix utilizing diatomite and silica gel (규조토 및 실리카겔을 혼입한 시멘트 경화체의 열전도율 특성)

  • Kim, Ki-Hoon;Pyeon, Su-Jeong;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.230-231
    • /
    • 2018
  • Recently, the danger for radioactive materials has become a hot topic. Beginning with the Chernobyl nuclear accident in 1996, in 2011, the Fukushima nuclear power plant in Japan suffered major damage such as large-scale casualties and radioactive dangerous area selection. Concerns about leakage of radioactive materials due to recent earthquakes have been deepening in Korea, such as Wolsong Nuclear Power Plant in Gyeongju, and there is a growing interest in the safety of radioactive materials through the media and the media. However, the route to exposure to radioactive materials is not limited to these large-scale nuclear accidents. Typical examples of this are radioactive substances exposed in daily life. In the case of radon gas, the danger is being revealed through current events programs and news, and natural radiation exposure is attracting attention.

  • PDF

The Development of a Distribution Automation System with an Wireless Network (무선통신망을 이용한 배전자동화시스템 개발 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2747-2749
    • /
    • 2000
  • The KEPRI has been developing the medium/small scale Distribution Automation System(DAS) that adopts wireless transmission media for exchanging information between master and remote terminals. It was concluded that Short Message Service(SMS) of Personal Communication Service(PCS) was the best wireless transmission media for the medium/small scale DAS in the last year. However. we had problem that PCS had long transmission delay. Therefore. SMS phones will be substituted with Radio Link Protocol(RLP) modems having transmission delay less than 5 seconds. This paper describes wireless networks for DAS, practical experience.

  • PDF