• Title/Summary/Keyword: measuring weight

Search Result 1,168, Processing Time 0.024 seconds

A Study of Body Surface Area Calculation -Centering around 40 Ages- (체표면적 산출식에 관한 연구 -40대 여성을 중심으로-)

  • Im, Soon
    • The Research Journal of the Costume Culture
    • /
    • v.2 no.2
    • /
    • pp.385-394
    • /
    • 1994
  • Data of the body surface is a necessary unit for the measuring of metabolism energy and activity energy. And also, these data are referring to check the degree of retaining warmth of clothes, to find the effect of heat insulation according to body surface, to calculate an average temperature of skin, and to study the several fields of clothing. In measuring of body surface, it si actually impossible to measure a subject's body surface in each experiment. As the experimental method, both gypsum method, by which the shape of body an be copied as it is, and the weighting method from which planed body surface area can be measured with consistent thickness of polyprophylene film as used. In fact, every female subject feels uncomfortable to measure her body surface as a naked body. There, it is providing a simple, accurate regressive equation with weight & height as variable factors in this study. This equation is as=117.02W+77.31H-3344.94 with average error : 0.1%, absolute average error : 2.07%.

  • PDF

The Improvement of Experimental Method of Textiles, Home Economics in High School (고등학교 가정과목의 피복재료 실험 방법 개선)

  • 유복현;이전숙
    • Journal of Korean Home Economics Education Association
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 1995
  • This study was intended to provide an improved method for testing textiles in high school. Four kinds of test subjects were selected and applied to the classes. Problems of the methods in the textbooks were corrected as follows: 1)Burning test: The number of specimen is reduced to 3 kinds of fibers(cotton, wool, and polyester) and recommends are given to make result by comparing with the burning characteris-tics of paper and hair. 2) Absorbency test: Test Method is changed to drop test. The result is recorded by measuring time required for the water drops absorbed to the specimen. 3) Wrinkle recovery test: A glass is provided instead of metal weight. The method of measuring angle which is made by the specimen is shown in figure. 4) Effects of Detergent: 0.2% of detergent solution is provided before class. The amount of oil and carbon black is specified. Students have generally agreed that the improved methods were better than those in the text-books after they made the above 4 recommendable experiments(p<.001)

  • PDF

Optimum electrode selection for measuring the abdominal pressure using bio-impedance method (비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정)

  • An, Yang-Su;Kim, Keo-Sik;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

Development of Computer Measurement and Control System for Plant Growth Responses (식물(植物)의 생장반응(生長反應) 계측(計測)을 위한 컴퓨터 계측(計測) 및 제어(制御) 시스템 개발(開發))

  • Kim, M.S.;Choi, D.S.;Park, J.M.;Ryu, K.H.;Noh, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 1993
  • This study was conducted to develop the on-line monitoring system for plant growth responses. The system consisted of two parts. One system was the measuring system and the other was its controlling system. The established measuring systems were the ultrasonic wave sensor driver for height of plant, the potentiometer for diameter of plant stem, and the weighing system with strain gage application for plant weight. Also, computer program for measurement and controlling was developed, and the whole system was tested by the fabricated plant, and the actual plant growth responses were monitored by the system. When monitoring the actual plant growth responses, even the small amount of plant growth resposes could be measured by the system within tolerable error ranges.

  • PDF

Development of optical temperature distribution measurement system for Underground Power Transmission tunnel (지중선로의 분포 온도 측정 시스템 개발)

  • Lee, Keun-Yang;Song, Woo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

Evaluation of Navigational Safety Using the Integrated Seakeeping Performance Index under Loading Conditions of a Ship (선박의 적화 상태별 종합내항성능지표에 의한 항해 안전성 평가)

  • 김순갑;김정만;공길영
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.2
    • /
    • pp.43-52
    • /
    • 1998
  • Generally, the navigational safety of a ship under various loading conditions is evaluated by a loading manual. However, the loading manual handles only statical factors such as weight and buoyancy of ship without including any wave conditions. Practically ship's safety is much concerned with the occurrences on the rough sea as propeller racing, rolling, deck wetness, vertical acceleration, lateral acceleration, slamming and so on. The purpose of this paper is to present a synthetic and practical evaluation method of navigational safety using the integrated seakeeping performance index(ISPI) under loading conditions of ship in seaways. The method is calculated by means of the ISPI by measuring only vertical acceleration. Judgement of dangerousness is carried out for four lading conditions : homogeneous full loaded, half loaded, heavy ballast loaded, and normal ballast loaded conditions. In developing the practical evaluation system of navigational safety, it is useful to solve the difficulties in measuring factors by sensors. And by applying the evaluation diagrames, navigators are able to avoid dangerousness by keeping away of the danger encountering angle of wave direction which the diagram shows.

  • PDF

A Paired Barrel Capable of Automatic Storage and Emptying of Water for a Weighing Raingauge (자동 저수와 배수가 가능한 중량 우량계 용 쌍수조)

  • Lim, Gyu-Ho;Lim, Eun Ok
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The standard weighing raingauges have a capacity limit in measuring the amounts of precipitation. Exceptions are those using a siphon to drain the collected water during observations. To reduce the drain time of the siphon type or to overcome the hassles associated with the manual emptying of the bucket for measuring, the most of weighing gauges use a large bucket for storing of rainwater to be measured. To avoid the above-mentioned adverse requirements, we propose a paired barrel for a weighing raingauge. The paired barrel may improve the accuracy of the weighing raingauges by getting rid of their capacity limit and make the gauges smaller in size and lighter in weight than the conventional ones. We showed its proper function and the feasibility of realization by testing a prototype paired barrel.

Development of WIM System Using Digital Loadcell (디지털 로드셀을 이용한 WIM 시스템의 개발)

  • Park, Chan-Won;Jeon, Chan-Min;Park, Heung-Joon
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.55-61
    • /
    • 2003
  • In this study, a signal processing and related techniques for development of a weight measuring system using a digital loadcell which is able to satisfy the important properties of WIM (weighing-in-motion) system have been investigated. A fast and high accurate signal processing of the digital load cell sensor for weighing-in-motion system is presented. A/D conversion system is constructed to realize a stable A/D conversion and signal processing algorithm using DSP and microprocessor. A new technique for vibration and measuring speed of the system is also investigated. The proposed method was applied to the actual design and the experimental results showed good performance of the weighing speed and stability.

  • PDF

Weighing control of alloy metal for electric arc furnace by fuzzy system (퍼지 시스템을 사용한 전기로 합금철 계량 제어)

  • Lee, Gi-Bum;Heo, J.H.;Joo, Moon-G.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.6
    • /
    • pp.821-825
    • /
    • 2008
  • A fuzzy control algorithm is used to weigh alloy metal into electric arc furnace and implemented by using ladder program for programmable logic controller, where weight error and its derivative are used for input variables and vibration amplitude of alloy bin is used for output variable. Proposed fuzzy control algorithm is applied to the plant and results in higher measuring accuracy as well as faster measuring term than conventional on-off control system.

Determination of Dosage of Flocculants for Paper Wastewater Treatment by Measuring Floc Strength (제지폐수의 플럭강도 측정에 따른 고분자응집제 주입량 결정)

  • Cho, Jun-Hyung;Kang, Mee-Ran
    • Journal of Forest and Environmental Science
    • /
    • v.23 no.2
    • /
    • pp.119-122
    • /
    • 2007
  • Actually, about 45% of total costs for wastewater treatment in a papermaking mill is spent for sludge disposal and the cost of chemicals used to improve the dewaterability of sludge takes much part of it. In order to reduce sludge disposal cost and to improve the efficiency of sludge treatment, it is necessary to minimize the amount of water contained within the sludge and hence to improve the dewaterability of the sludge. The objective of this study was to elucidate the way of improving the dewaterability of sludge. Three types of wastewater from a tissue paper mill, a printing paper mill and a newsprint mill were used and two types of high molecular weight flocculants (anionic PAM and cationic PAM) were used to treat the wastewater. Dewaterability of sludge was evaluated by measuring floc strength.

  • PDF