• Title/Summary/Keyword: measuring tool

Search Result 1,280, Processing Time 0.032 seconds

Development and Application of a Tool for Measuring on a Scientist Image by the Semantic Differential Method (의미분석법에 의한 과학자 이미지 측정도구 개발 및 적용)

  • Youngwook Song;Hyukjoon Choi
    • Journal of Science Education
    • /
    • v.48 no.1
    • /
    • pp.63-73
    • /
    • 2024
  • Knowing the learner's image of a subject-related occupation is good data for determining the direction of a teacher's teaching and learning. Existing drawing image analysis tools have the limitation that it takes a long time to analyze images and drawings of a scientist's appearance. The semantic differential method is a widely used method to analyze images of specific objects. However, research using the semantic differential method has the limitation of failing to reflect terms or factors that change over time by using the adjective pairs used in the initial study as they were in accordance with the research content. In this study, we use the semantic differential method to develop a tool to measure middle school students' scientist image and apply it to middle school students to discuss educational implications regarding the usefulness of measuring scientist image.

The Characteristics of the Milling Tool Deflection According to the Variation of Helix Angle (헬릭스각의 변화에 따른 밀링공구의 변위 특성 연구)

  • Maeng, Min-Jae;Chung, Joon-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.6
    • /
    • pp.860-866
    • /
    • 2004
  • In the end milling operation the deflection of the cutter is an important factor affecting the accuracy of machining, with implications on the selection of cutting parameters and economics of the operation. Several studies were devoted to the end mill deflection and its effects, notably, providing a useful insight into the problem. Although the deflection affects adversely the accuracy, the flexibility of the cutter is beneficial in attenuating the overload in a sudden transient situation, as well as in attenuating chatter. The deflection of the end mill was studied both experimentally with strain gauge, tool dynamometer, laser measuring apparatus and on a finite element model of the cutting using ANSYS software. The deflection of machining tool with various helix angles was studied with FEM simulation and experiment. ANSYS analysis performed on the finite element model of the end mill provides deflection results which agree within 15.0% with the experimental ones.

Improvement of the Quality of Cryogenic Machining by Stabilization of Liquid Nitrogen Jet Pressure (액체질소 분사 안정화를 통한 극저온가공 품질 향상)

  • Gang, Myeong Gu;Min, Byung-Kwon;Kim, Tae-Gon;Lee, Seok-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.247-251
    • /
    • 2017
  • Titanium alloy has been widely used in the aerospace industry because of its high strength and good corrosion resistance. During cutting, the low thermal conductivity and high chemical reactivity of titanium generate a high cutting temperature and accelerates tool wear. To improve cutting tool life, cryogenic machining by using a liquid nitrogen (LN2) jet is suggested. In cryogenic jet cooling, evaporation of LN2 in the tank and transfer tube could cause pressure fluctuation and change the cooling rate. In this work, cooling uniformity is investigated in terms of liquid nitrogen jet pressure in cryogenic jet cooling during titanium alloy turning. Fluctuation of jet spraying pressure causes tool temperature to fluctuate. It is possible to suppress the fluctuation of the jet pressure and improve cooling by using a phase separator. Measuring tool temperature shows that consistent LN2 jet pressure improves cryogenic cooling uniformity.

An Experimental Study of the Performance Characteristics with Four Different Rotor Blade Shapes on a Small Mixed-Type Turbine

  • Cho Soo-Yong;Cho Tae-Hwan;Choi Sang-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.7
    • /
    • pp.1478-1487
    • /
    • 2005
  • A small mixed-type turbine with a diameter of 19.9 mm has been substituted for a rotational part of pencil-type air tool. Usually, a vane-type rotor is applied to the rotational part of the air tool. However, the vane-type rotor has some problems, such as friction, abrasion, and necessity of accurate assembly etc.,. These problems make the life time of the vane-type air tool short, but air tools operated by mixed-type turbines are free of friction and abrasion because the turbine rotor dose not contact with the casing. Moreover, it is assembled easily because of no axis offset. These characteristics are merits for using air tools, but loss of power is inevitable on a non-contacting type rotor due to flow loss, tip clearance loss, and profile loss etc.,. In this study, four different rotors are tested, and their characteristics are investigated by measuring the specific output power. Additionally, optimum nozzle location against the rotor is studied. Output powers are obtained through measured pressure, temperature, torque, rotational speed, and flow rate. The experimental results obtained with four different rotors show that the rotor blade shape greatly influences to the performance, and the optimum nozzle location exists near the mid span of the rotor.

A Comparative Study of SERVQUAL and SERVPERF in Measuring the Pallet Pool Service Quality (파렛트 Pool 서비스품질 측정에 있어서 SERVQUAL과 SERVPERF 모형비교 연구)

  • Oh, Sun-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.157-167
    • /
    • 2011
  • Currently, interest on physical distribution is increasing due to burden of oil cost increases as oil price rises day by day. As interest grows, there are number of studies have been conducting on saving the cost of distribution. On the other hand, number of study on service of distribution is insufficient. Actually, subject of service of physical distribution have been studied by number of survey organizations, research organizations and mass media. Although, configuration for each organization is different from each other and it is hard to measure objective satisfactory factor of customers. This means needs for constructing standardized measuring tool as well as research on measuring service quality of distribution is not active. Therefore, this research is to compare and analyze compatibility of service quality measuring using SERVQUAL and SERVPERF and trying to clarify differences affected by importance service quality by each level to actual service quality. Also, this research is to make basic and standardized measuring model to improve quality of physical distribution especially using analysis of service quality and customer satisfaction of pallet pool service which contributes rationalization of distribution and reduce the cost by standardizing specification and size of pallet, allowing sharing of pallet. To conduct this research, case study of a company A is used where it is in a pallet pool business. Using this example, the goal is to give help on pallet pool business a strategic exercise if the business by point out major factors that affect customer satisfaction by collecting customer assessment along with examination of SERVQUAL and SERVPERF in measuring service quality if pallet pool service.

Development of the Reading Attitudes Test Tool for Children (아동의 독서태도 검사도구 개발)

  • Park, Ju-Hyeon
    • Journal of Korean Library and Information Science Society
    • /
    • v.47 no.2
    • /
    • pp.329-358
    • /
    • 2016
  • The purpose of this study is to develop a test tool that can be measured in various aspects for the reading attitudes of children. For that it was set the configuration based on the preceding reading attitude survey and models and tacit knowledge of attitude toward reading and wrote the questions for reading attitudes. It conducted a primary and secondary test for elementary school students in grades 4-6 to verify the validity and reliability of measurement tools. 8 factors of the reading attitudes measurement tool were extracted through exploratory factor analysis and it described 66.29% of total variable. the r-value for inter-item consistency about reading attitudes were above 0.4 on all questions. The Cronbach ${\alpha}$-value of reliability coefficient about reading attitudes measurement tool was 0.950. Therefore Reading attitude test tool have reading usefulness, reading efficacy, leisure, stiumulation, flow, expression, study, assertiveness as sub factors of reading attitude has been shown that it can serve as a useful tool for measuring various aspects of the reading attitude for children.

Analysis on the development necessity of a safety health knowledge test for young children (유아 안전보건지식 측정도구 개발 필요성에 대한 분석)

  • Kwak, Eunbog;Choi, Gyu yil
    • Journal of Digital Convergence
    • /
    • v.18 no.8
    • /
    • pp.511-518
    • /
    • 2020
  • The purpose of this study is to emphasize the importance of the safety and health ability to safely protect body in a risky situation in infancy, but due to the lack of a valid test tool for measuring infant safety knowledge, measure the safety and health knowledge of infants. In order to achieve the purpose of the study, opinions of education experts and early childhood education experts were collected, and suitable factors for measuring safety and health knowledge of children aged 3-5 years were extracted. The measurement questions developed based on this were surveyed on 186 children aged 3-5 years old to verify the relevance of the question composition and the reliability of the contents. In the distribution of the item response, values of 0.8 or less were deleted, and items with a correlation of r<.40 or less were also deleted, and the reliability test showed more than .70. After exploratory factor analysis, it was developed into 23 questions in 3 areas. The total score of safety and health knowledge for the final question and the degree of correlation were above .80. The tool for measuring child safety and health knowledge developed in this study was confirmed to be appropriate for item discrimination, item reliability, and content validity, and thus will be used as basic data for measuring child safety and health knowledge. After the early childhood safety and health education program is implemented, Further research should verify the effectiveness of the early childhood safety and health program.

Development and Validation of Mathematics Self Efficacy Scale for Elementary Students (초등학생의 수학 자기 효능감 검사 도구 개발에 관한 연구)

  • Kim, Rina
    • Education of Primary School Mathematics
    • /
    • v.23 no.2
    • /
    • pp.63-72
    • /
    • 2020
  • The purpose of this study is to develop a mathematics self-efficacy test tool for elementary school students based on the sub-factors of mathematical self-efficacy derived from current studies. In this study, I verified the validity and reliability of the test tool by statistically evaluating the results of applying the test tool to the 3rd-6th grade students. In this study, Principal Component Analysis was performed on the tool for measuring the self efficacy of mathematics for elementary school students. For the validity test, the mathematics anxiety status of the participants was measured. The mathematics anxiety who were known to have a negative correlation with the mathematical self efficacy. The mathematics self efficacy tool developed in this study consists of 16 items with three subcategories: master experience, social persuasions, and emotional and physiological state. The mathematical self efficacy test tool developed in this study is expected to provide grounds for diagnosing the mathematics self-efficacy status of elementary school students and looking for ways to improve it.

The Artificial Intelligence Literacy Scale for Middle School Students

  • Kim, Seong-Won;Lee, Youngjun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.225-238
    • /
    • 2022
  • Although the importance of literacy in Artificial Intelligence (AI) education is increasing, there is a lack of testing tools for measuring such competency. To address this gap, this study developed a testing tool that measures AI literacy among middle school students. This goal was achieved through the establishment of an expert group that was enlisted to determine the relevant factors and items covered by the proposed tool. To verify the reliability and validity of the developed tool, a field review, exploratory factor analysis, and confirmatory factor analysis were conducted. These procedures resulted in a testing tool comprising six domains that encompass 30 items. The domains are the social impact of AI (eight items), the understanding of AI (six items), AI execution plans (five items), problem solving with AI (five items), data literacy (four items), and AI ethics (two questions). The items are to be rated using a five-point Likert scale. The internal consistency of the tool was .970 (total), while that of the domains ranged from .861 to .939. This study can serve as reference for developing the analysis of AI literacy, teaching and learning, and evaluation in AI education.

Analysis of Sarcopenia Using an Integrated Evaluation Tool : Targeting the elderly over 65 years of age in Korea (통합적 평가 도구를 활용한 근감소증 분석 : 국내 65세 이상 노인을 대상으로)

  • Chae-Rim Park;Hae-In Kim;Myung-Chul Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.31-41
    • /
    • 2023
  • Purpose : This study was conducted to identify the common characteristics of older persons with sarcopenia and to explore the relationship between gait, balance, and stress using an integrated assessment tool. Methods : In this study, 95 people aged 65 years or older were screened using the sarcopenia diagnostic evaluation algorithm presented by the Asian Working Group for Sarcopenia in 2019. Skeletal muscle index, grip strength, and short physical performance battery were used as sarcopenia evaluation measurements. Based on the results of this evaluation, participants were grouped into the 'non-sarcopenia group' (41 participants) or the 'sarcopenia group' (54 participants). Participants underwent further assessment using an integrated evaluation tool capable of measuring gait, balance, and stress. Gait ability was evaluated using the timed up and go test, and balance ability was evaluated using the berg balance scale. And the stress of the last month was measured by modifying the stress index developed by a Korean researcher. Collected data were statistically analyzed using the independent t-test and Mann Whitney-U test. Results : The sarcopenia group and the non-sarcopenia group showed significant differences in all elements of the sarcopenia diagnostic evaluation. There were significant differences in all three integrated evaluation tools. For the evaluation of walking ability, the time measured in the timed up and go test was longer in the sarcopenia group, the berg balance scale score for the evaluation of balance ability was lower in the sarcopenia group, and the stress index was higher in the sarcopenia group. Conclusion : Through sarcopenia analysis using an integrated evaluation tool, it was confirmed that sarcopenia is closely related to decreased walking ability, poor balance, and increased stress. We recommend using this tool to reduce the risk of sarcopenia progression and stress exposure through the planning and implementation of an exercise program for sarcopenia prevention.