Force monitoring of steel cables using vision-based sensing technology: methodology and experimental verification

  • Ye, X.W.;Dong, C.Z.;Liu, T.
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.585-599
    • /
    • 2016
  • Steel cables serve as the key structural components in long-span bridges, and the force state of the steel cable is deemed to be one of the most important determinant factors representing the safety condition of bridge structures. The disadvantages of traditional cable force measurement methods have been envisaged and development of an effective alternative is still desired. In the last decade, the vision-based sensing technology has been rapidly developed and broadly applied in the field of structural health monitoring (SHM). With the aid of vision-based multi-point structural displacement measurement method, monitoring of the tensile force of the steel cable can be realized. In this paper, a novel cable force monitoring system integrated with a multi-point pattern matching algorithm is developed. The feasibility and accuracy of the developed vision-based force monitoring system has been validated by conducting the uniaxial tensile tests of steel bars, steel wire ropes, and parallel strand cables on a universal testing machine (UTM) as well as a series of moving loading experiments on a scale arch bridge model. The comparative study of the experimental outcomes indicates that the results obtained by the vision-based system are consistent with those measured by the traditional method for cable force measurement.

제주월드컵경기장 지붕지지 케이블의 시공 (Construction of Cable Staying Roof Structure of Jeju Worldcup Stadium)

  • 이주영;김찬수
    • 한국공간구조학회논문집
    • /
    • 제2권4호
    • /
    • pp.37-44
    • /
    • 2002
  • The cable staying roof structure of Jeju worldcup stadium should be erected with correct prestressed force that is required by the structural engineer who designs this structure. This study evaluated and adapted the erection process of cable, the erection force and the measurement of cable force for Jeju worldcup stadium. The process of erection is required not only to calculate erection force but also to check structural stability, following process, construction period and using cranes. Considering the site conditions and technical problems, this study can attain successfully the erection of cable staying roof structure of Jeju worldcup stadium with allowable errors.

  • PDF

제주월드컵경기장 지붕구조물의 시공 (Construction of Roof Structure for Jeju Worldcup Stadium)

  • 이주영;김찬수
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2002년도 학술대회지
    • /
    • pp.174-179
    • /
    • 2002
  • 케이블로 지지되는 제주월드컵경기장의 지붕구조물이 구조적으로 안정한 거동을 하기 위해서는 케이블의 시공시 구조설계자가 요구하는 정확한 초기장력을 케이블에 부여해야 한다. 본 연구에서는 케이블의 시공을 위하여 장력도입 절차와 절차에 따른 장력의 계산을 기하학적 비선형을 고려한 유한요소해석을 통하여 수행하여 그 유효성을 평가하고 적용하였다. 지붕구조물을 지지하는 케이블에 장력을 도입하는 작업은 정확한 장력의 계산뿐 아니라, 각 작업을 진행 중 구조적으로 안정성을 확보해야 하며, 작업공정을 최소로 줄이고 후속공정에 영향을 미치는 요인을 분석하여 최소한 공기와 효율적인 장비의 운용되도록 계획하여야 한다. 본 연구에서는 현장의 여건과 기술적 오류를 보완하기 위한 작업 절차의 변경 등을 고려하여 제주월드컵경기장의 지지케이블의 장력을 허용오차범위내에서 조정할 수 있었다.

  • PDF

Innovative cable force monitoring of stay cables using piezoelectric dynamic strain responses

  • ;;이지용;신성우;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.830-834
    • /
    • 2013
  • This study presents a method to monitor cable force of a long-span cable-stayed bridge using a smart piezoelectric sensor system. The following approaches are implemented in order to achieve the objective. Firstly, the method to utilize piezoelectric materials for the health monitoring of stay cables is presented. For strain measurement of a stay cable, a PZT-embedded smart skin is designed to overcome the difficulties of bonding PZT sensors directly on stay cables. Secondly, a piezoelectric strain monitoring system for stay cables is designed. For the operation of the sensor board, the Imote2 sensor platform is used to provide the computation, wireless communication and power supply units. The feasibility of the proposed monitoring system is then evaluated on a full-scale cable of a cable-stayed bridge.

  • PDF

Damage detection of a cable-stayed bridge based on the variation of stay cable forces eliminating environmental temperature effects

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.859-880
    • /
    • 2016
  • This study aims to establish an effective methodology for the detection of instant damages occurred in cable-stayed bridges with the measurements of cable vibration and structural temperatures. A transfer coefficient for the daily temperature variation and another for the long-term temperature variation are firstly determined to eliminate the environmental temperature effects from the cable force variation. Several thresholds corresponding to different levels of exceedance probability are then obtained to decide four upper criteria and four lower criteria for damage detection. With these criteria, the monitoring data for three stay cables of Ai-Lan Bridge are analyzed and compared to verify the proposed damage detection methodology. The simulated results to consider various damage scenarios unambiguously indicate that the damages with cable force changes larger than ${\pm}1%$ can be confidently detected. As for the required time to detect damage, it is found that the cases with ${\pm}2%$ of cable force change can be discovered in no more than 6 hours and those with ${\pm}1.5%$ of cable force change can be identified in at most 9 hours. This methodology is also investigated for more lightly monitored cases where only the air temperature measurement is available. Under such circumstances, the damages with cable force changes larger than ${\pm}1.5%$ can be detected within 12 hours. Even though not exhaustively reflecting the environmental temperature effects on the cable force variation, both the effective temperature and the air temperature can be considered as valid indices to eliminate these effects at high and low monitoring costs.

행어케이블의 동특성 추정을 위한 영상계측시스템 적용 (Application of Vision-based Measurement System for Estimation of Dynamic Characteristics on Hanger Cables)

  • 김성완;김남식
    • 대한토목학회논문집
    • /
    • 제32권1A호
    • /
    • pp.1-10
    • /
    • 2012
  • 최근 해안, 도서, 산간지방 등의 개발로 장대교량의 수요가 증가되고 재료 및 설계 시공기술의 지속적 발전으로 인하여 현수교나 사장교 등 장지간을 가지는 교량의 건설이 증가하고 있다. 장대교량은 사장재 또는 주 케이블 및 행어로 주형을 지지하는 고차 부정정구조물로 다양한 형태의 설계가 가능하고 구조물의 외관이 뛰어나기 때문에 현재 많은 교량에 적용되고 있다. 케이블지지교량은 시공 중 그리고 공용상태에서 케이블의 장력을 지속적으로 측정함으로써 교량의 건전성을 파악할 수 있다. 케이블의 장력을 추정하는 기법으로 로드셀 및 유압잭 등을 이용하여 케이블의 응력을 직접 측정하는 방법과 케이블의 형상조건과 계측된 동적 특성을 활용하여 장력을 구하는 진동법이 많이 활용되고 있다. 본 연구에서는 디지털 영상처리를 이용한 행어케이블의 동특성 추정 방법을 제시하였으며 사용의 편의성과 경제성을 고려하여 원거리에 있는 행어케이블을 측정하기 위한 센서로 휴대용 디지털 캠코더를 사용하였다. 디지털 영상처리를 이용하는 방법은 digital image correlation(DIC) 기법을 사용하였으며 변형이 없는 이미지와 변형이 있는 이미지 사이의 기하학적인 왜곡을 보정하는 이미지 변환함수(ITF)를 사용하여 단위픽셀이하를 계산하였다. 또한 영상계측시스템의 흔들림을 추가적인 센서의 설치 없이 한 영상내의 고정된 물체를 이용하여 보정함으로써 행어케이블의 동적응답 및 모드별 고유진동수의 해상도를 향상시켰다.

월드컵경기장 지지케이블의 장력추정을 위한 진동법의 적용성 평가 (Application of Vibration Method for Estimation of Tension Force of Stay Cables in World-Cup Stadiums)

  • 장극관
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권6호통권58호
    • /
    • pp.156-165
    • /
    • 2009
  • 본 연구에서는 대공간 구조물로서 2002년 건축된 6개 월드컵경기장 인장케이블의 특성과 관련하여 케이블의 고유진동수와 이를 이용한 기존 이론식들의 적용성에 대하여 실험적으로 검토하였다. 실험결과, 케이블의 휨강성을 고려함으로서 8%이내의 정확도를 가지고 케이블의 인장력을 추정할 수 있는 것으로 나타났으나 휨강성의 영향이 큰 범위(${\xi}{\leq}7$)에 있어서는 추정오차가 증가하는 경향을 나타내고 있어 이 범위에 대해서는 추가적인 연구가 필요한 것으로 사료되며, 다중진동모드를 사용하더라도 단일진동모드를 사용하는 경우와 비교하여 장력추정 오차는 크게 개선할 수 없는 것으로 나타났다.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

인버터 구동 유도전동기에서 과도전압의 측정과 분석 (Measurement and Analysis of Transient Overvoltages on Inverter-fed Induction Motors)

  • 박대원;김일권;최수연;박찬용;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1445-1450
    • /
    • 2007
  • Induction motors are the main driving force of electric vehicles and operated by pulse width modulation (PWM) inverters in speed control. Contrary to full-voltage operation of induction motors, inverter-fed induction motors (IFM) generates transient overvoltages up to 10 kV/us and transient overvoltages accelerate the deterioration of winding insulation. We investigated transient overvoltages produced by the operation of IFM and analyzed its peak value and dv/dt depending on power cable length and operation frequency. The experimental results showed that transient overvoltages measured at the motor terminal increased with the cable length between inverter and motor.

  • PDF