• Title/Summary/Keyword: measurement instrument

Search Result 986, Processing Time 0.028 seconds

A Study on Self-Esteem and Urinary Symptoms in Women with Urinary Incontinence (요실금환자의 골반근육운동에 따른 자아존중감과 배뇨증상에 관한 연구)

  • Lee Young-Hee;Kim Sun-Are
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.3
    • /
    • pp.360-369
    • /
    • 2002
  • Purpose: The purpose of this study was to help enhance the quality of life for women with urinary incontinence. Self-esteem, urinary symptoms, peak pressure and duration in seconds for vaginal contraction after pelvic muscles exercise were examined. Method: One-group pretest-posttest design was employed participants were 27 married women from G city. The instrument for this study were : the self-esteem scale developed by Rosenberg(1965). the Urinary Symptom Questionnaire, a subjective measurement of urinary incontinence, developed by Jackson et al.(1996) and the Perineometer used as an objective measurement of peak pressure and duration in seconds. Result: 1. Self-esteem showed significant improvement after the exercise (t=-3.832, p= .001). 2. Comparison of results before the pelvic muscles exercise and after showed that there was a statistically significant difference for several urinary symptoms including enuresis (t=2.833, p=.009), frequency of incontinence (t=2.964, p= .006), incontinence volume (t=2.280, p= .031), incontinence before getting to the restroom (t=3.035, p= .006), incontinence with no reason or feeling (t= 3.051, p= 005) burning sensation (t= 2.132, p=.043), and a sense of residual urine (t=2.267 p=.032). The mean scores showed improvement in the urinary symptoms of management of incontinence (M=$0.04{\pm}0.22$), daily frequency of incontinence management (M=$0.13{\pm}0.85$), urinary control (M=$0.15{\pm}0.86$), running to the restroom (M=$0.15{\pm}0.60$) incontinence caused by coughing or physical activities (M=$0.19{\pm}0.57$) and hesitancy (M=$0.07{\pm}0.55$). Overall urinary symptoms decreased significantly (t =3.073. p= .007). 3. Peak pressure showed an increase from a mean of $24.26{\pm}16.20mmHg$ before the exercise to a mean of $28.63{\pm} 17.79mmHg$ after (t=-2.399, p=.024). Duration in seconds also increased from a mean of $6.00{\pm}4.95sec$ to $9.15{\pm}5.83sec$ (t=-4.400, p= 000). Conclusion: These findings suggest that pelvic muscle exercise serves to decrease urinary problems, improve self-esteem and increase peak pressure and duration in seconds.

  • PDF

Study on the Applicability of Thermography as Severity Measurement in the Patients with Osteoarthritis of the Knee (퇴행성 슬관절염 환자의 증상 중증도 지표와 DITI의 상관성 연구)

  • Seo, Byung-Kwan;Ryu, Seong-Ryong;Kang, Jung-Won;An, Kyung-Eh;Lee, Jae-Dong;Choi, Do-Young;Kim, Keon-Sik;Lee, Doo-Ik;Lee, Yun-Ho;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.22 no.4
    • /
    • pp.35-45
    • /
    • 2005
  • Objectives : To investigate the applicability of thermography as severity measurement in the patients with osteoarthritis (OA) of the knee. Methods : Data were obtained from 80 patiens with OA of the knee. They were asked to answer two disease-specific questionnaire (Western Ontario and McMaster Universities (WOMAC) OA index. Lequesne's Functional Index (LFI)), one generic instrument (Korean Health Assessment Questionnaire (KHAQ)), VAS in order to assess the severity of disease, quality of life, and degree of pain and taken thermography in standardized environment. Results : The thermal difference between ipsilateral side and contralaterla side of lateral aspect of knee was correlated with that of medial aspect of knee, and the thermal difference of anterior thigh was correlated with that of lateral, medial aspect of knee and patella region. Age, duration of disease, duration of morning stiffness, sex, crepitus, and painful side of knee were not correlated with the thermal differences of each region. LFI, WOMAC, WOMAC pain subscale, WOMAC stiffness subscale, WOMAC physical function, KHAQ, VAS were not correlated with the thermal differences of each region. Conclusion : Futher study on the thermography on OA of the knee in population with appropriate severity grade and the standardization of analysis of thermographic data were recommended.

  • PDF

Sensitivity Analysis and Estimation of the Depth of Investigation in Small-Loop EM Surveys (소형루프 전자탐사의 감도분석 및 가탐심도 추정)

  • Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.299-308
    • /
    • 2002
  • We have derived an analytical expression for the sensitivity of the frequency domain small-loop electromagnetic (EM) surveys over a two-layer earth in order to estimate the depth of investigation with an instrument having the source-receiver separation of about 2 m. We analyzed the sensitivities to the lower layer normalized by those to the upper half-space and estimated the depth of investigation from the sensitivity analyses and the mutual impedance ratio. The computational results showed that the in-phase components of the sensitivity to the lower layer dominates those to the upper layer when the thickness of the upper layer is less than 20 m, while the quadrature components are not sensitive to the lower layer over the entire frequency range. Hence we confirmed that the accurate measurement of the in-phase component is essential to increase the depth of investigation in the multi-frequency small-loop EM survey. When conductive basement of 10 ohm-m underlies the upper layer of 100 ohm-m, an accurate measurement of the in-phase components ensures the depth of the investigation more than 10 m even accounting a noise effect, from which we conclude that the small-loop EM survey is quite effective in imaging the conductive plume down to a considerable depth. On the other hand, in the presence of the resistive basement of 1,000 ohm-m, the depth of investigation may not exceed 5 m considering the instrumental accuracy, which implies that the application of the small-loop EM survey is not recommended over the resistive environment other than detecting the buried conductor.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

The Effects of Online User Instruction on Information Literacy Ability: Suggestions for COVID-19 Era (코로나 시대의 온라인 도서관 이용교육이 정보활용능력에 미치는 영향)

  • Park, Yeon Kyeong;Yi, Yong Jeong
    • Journal of Korean Library and Information Science Society
    • /
    • v.52 no.3
    • /
    • pp.267-285
    • /
    • 2021
  • Due to COVID-19, user instruction programs could not be conducted face-to-face, and the sessions have been moved online. The present study attempted to investigate how online user instruction influences the information literacy ability of college students. The study randomly selected college students (N=50) who completed online user instruction sessions and college college students (N=50) who did not complete them among freshment who went to to college in 2020 to measure their information literacy abilities. For this study, a tool for measuring information literacy abilities was developed by referring to several previous studies. The measurement results were analyzed by the independent samples t-test, and significant differences were found between students who completed online user instruction sessions and those who did not. The findings of the study have confirmed that it is effective in enhancing library users' information literacy abilities to provide user instruction online under the COVID-19 situation, and even in post-COVID 19 times, which helps them appropriately utilize the characteristics of digital libraries. The information literacy measurement tool used in the present study was developed to evaluate online information literacy, and thus contributed to the extension of the literature of digital information literacy and user instruction. The present study provided practical implications for how academic libraries will promote information services to cope with environmental changes in which contact-free (untact) services are obliged.

A Study on Admissibility Framework for Establishing Trust in Digital Records : Focused on the Development of the Trustworthiness Model for Public Digital Records (전자기록의 신뢰가치 확립을 위한 증거능력 구현체계 연구 우리나라 공공 전자기록의 신뢰가치 모델 개발을 중심으로)

  • Hyun, Moonsoo
    • The Korean Journal of Archival Studies
    • /
    • no.73
    • /
    • pp.5-46
    • /
    • 2022
  • This study aims to develop the trustworthiness model for public digital records, as an admissibility framework for establishing trust. The trustworthiness model is deemed to used to identify the qualities of the digital records in their lifecycle, including the identity that could be identified at the time of the creation, integrity obtained from the chain-of-custodial management, the evidence of relationship between business activities and records, and the technical or cognitive accessibility. Based on the analysis of the QADEP model, it was decided to develop a model that could measure the trustworthiness of public digital records in the external measurement type, which are authenticity, reliability, and usability. In line with this direction, the model expanded measurement areas and indicators of the QADEP model through the analysis of ISO 16175-1:2020, and measuring metrics was also proposed so that it could be a measuring instrument for public digital records in Korea, after analysing NAK 19-3. It would be useful to expand the model and to test the approach of the trustworthiness model for public digital records.

Evaluation of Measurement Accuracy for Unmanned Aerial Vehicle-based Land Surface Temperature Depending on Climate and Crop Conditions (기상 조건과 작물 생육상태에 따른 무인기 기반 지표면온도의 관측 정확도 평가)

  • Ryu, Jae-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.211-220
    • /
    • 2021
  • Land Surface Temperature (LST) is one of the useful parameters to diagnose the growth and development of crop and to detect crop stress. Unmanned Aerial Vehicle (UAV)-based LST (LSTUAV) can be estimated in the regional spatial scale due to miniaturization of thermal infrared camera and development of UAV. Given that meteorological variable, type of instrument, and surface condition can affect the LSTUAV, the evaluation for accuracy of LSTUAV is required. The purpose of this study is to evaluate the accuracy of LSTUAV using LST measured at ground (LSTGround) under various meteorological conditions and growth phases of garlic crop. To evaluate the accuracy of LSTUAV, Relative humidity (RH), absolute humidity (AH), gust, and vegetation index were considered. Root mean square error (RMSE) after minimizing the bias between LSTUAV and LSTGround was 2.565℃ under above 60% of RH, and it was higher than that of 1.82℃ under the below 60% of RH. Therefore, LSTUAV measurement should be conducted under the below 60% of RH. The error depending on the gust and surface conditions was not statistically significant (p-value < 0.05). LSTUAV had reliable accuracy under the wind speed conditions that allow flight and reflected the crop condition. These results help to comprehend the accuracy of LSTUAV and to utilize it in the agriculture field.

Instrumentation Management of the Deep Soft Ground with Dredged Clay Reclaimed in the Upper (준설점토가 상부에 매립된 대심도 연약지반 계측관리)

  • Jung, Na-Young;Kang, Seung-Chan;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.67-78
    • /
    • 2022
  • In this study, the measurement results of the coastal deep soft ground buried in the upper part of the dredged clay were analyzed and compared with the current specification standards. Based on the results, a suitable proposal was suggested for the selection, installation, data arrangement, and analysis of each instrument used in the deep soft ground improvement construction. The pore water pressure meter has a range of 1.5 times or more of the expected measurement range, considering the field conditions of the soft ground. The groundwater level meter installed in the horizontal drainage layer checks the change in the groundwater level during the embanking as well as the performance of the catchment well and the horizontal drainage layer. Therefore, it is important to manage so that the groundwater level exists inside the horizontal drainage layer during embanking. It is enough to install the inclinometer in the gravel layer below the soft ground or weathered rock with an N value of 40 or more for the deep soft ground. It seems desirable to install a screw type for differential settlement meter. However, the screw type should not settle due to its own weight. Considering that it is a dredged landfill where subsidence occurs significantly, it is sufficient to manage the tolerance of leveling at about 10 mm (L is the one-way distance (km)).

Measurement of PM2.5 Concentrations and Comparison of Affecting Factors in Residential Houses in Summer and Autumn (여름과 가을의 주택실내 초미세먼지(PM2.5) 농도 측정 및 영향요인 비교)

  • Dongjun Kim;Gihong Min;Jihun Shin;Youngtae Choe;Kilyoong Choi;Sang Hyo Sim;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.16-24
    • /
    • 2024
  • Background: Indoor PM2.5 concentrations in residential houses can be affected by various factors depending on the season. This is because not only do the climate characteristics depend on the season, but the activity patterns of occupants are also different. Objectives: The purpose of this study is to compare factors affecting indoor PM2.5 concentrations in apartments and detached houses in Daegu according to seasonal changes. Methods: This study included 20 households in Daegu, South Korea. The study was conducted during the summer (from July 10 to August 10, 2023) and the autumn (from September 11 to October 9, 2023). A sensor-based instrument for PM2.5 levels was installed in the living room of each residence, and measurements were taken continuously for 24 hours at intervals of one minute during the measurement period. Based on the air quality monitoring system data in Daegu, outdoor PM2.5 concentrations were estimated using ordinary kriging (OK) in Python. In addition, the indoor activities of the occupants were investigated using a time-activity pattern diary. The affecting factors of indoor PM2.5 concentration were analyzed using multiple regression analysis. Results: Indoor and outdoor PM2.5 concentrations of the residences during summer were 15.27±11.09 ㎍/m3 and 11.52±7.56 ㎍/m3, respectively. Indoor and outdoor PM2.5 concentrations during autumn were 13.82±9.61 ㎍/m3 and 9.57±5.50 ㎍/m3, respectively. The PM2.5 concentrations were higher in summer compared to autumn both indoors and outdoors. The primary factor affecting indoor PM2.5 concentration in summer was occupant activity. On the other hand, during the autumn season, the primary affecting factor was outdoor PM2.5 concentration. Conclusions: Indoor PM2.5 concentration in residential houses is affected by occupant activity such as the inflow of outdoor PM2.5 concentration, cooking, and cleaning, as found in previous studies. However, it was revealed that there were differences depending on the season.

Investigation of the Effects of Wavelength Range and Absorption Cross-Section on Sulfur Dioxide Slant Column Density Retrieval Using Ground-Based UV Scattered Sunlight Measurement (지상 기반 태양 UV 산란광 관측을 이용한 이산화황 경사칼럼농도 산출 시 파장 구간 및 흡수단면적에 따른 영향 조사)

  • Gyeong Park;Buju Gong;Minji Kim;Hanlim Lee
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.377-385
    • /
    • 2024
  • We investigated the effect of spectral fitting wavelength interval variations and selection of absorption cross-section on the sulfur dioxide slant column density (SCD) retrievals from the scattered sunlight observation using a UV-Vis hyperspectral instrument. The sulfur dioxide slant column densities were retrieved from the combinations of multiple spectral fitting intervals and absorption cross-sections. The observation was carried out at the site 0.53 km away from a combustion site located in Gimhae from December 1, 2023, to January 23, 2024. The radiances were obtained on the line of measurement sight toward the stack of the combustion facility. The best spectral fitting intervals were found to be from 305.7 to 321.1 nm. In terms of the absorption cross-section dependency, the SO2 (293 K), O3 (223 K, 243 K) show the best spectral fitting for the observed radiances with both the smallest fitting residual and SCD error. The effects of the fitting interval and cross sections found in this study can be useful information for improving SO2 retrievals based on UV hyperspectral measurements.