• 제목/요약/키워드: measurement device

검색결과 2,571건 처리시간 0.03초

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

스마트온실 배양액 관리를 위한 클라우드 기반 데이터 분석시스템 설계 (Design of Cloud-Based Data Analysis System for Culture Medium Management in Smart Greenhouses)

  • 허정욱;박경훈;이재수;홍승길;이공인;백정현
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.251-259
    • /
    • 2018
  • 스마트온실에서 사용하고 있는 다양한 종류의 수경배양액 관리와 관련하여 ICT 기술을 활용한 작물생육 기반 배양액 제어시스템 개발을 위하여, 본 연구에서는 작물 생육단계별 시용배양액의 성분변화를 모니터링하고 이들 실측 데이터를 바탕으로 한 클라우드 기반 데이터 분석시스템을 설계하였다. 수집한 데이터 분석 및 시스템 구축을 위하여 인공광 스마트 온실에서 사용하는 관행의 무기 배양액, 기존 액비 및 폐기 농업부산물 유래 제조액비 등 수종의 배양액을 공시하였으며, 수경재배 작물 생육단계별 시용 배양액내 성분 변화패턴을 모니터링하였다. 발색법에 의한 흡광광도법을 활용하여 $NH_3-N$, $NO_3-N$, $NO_2-N$, $SiO_2$, $PO_4^{3-}$ 및 Cu 등 총 9종의 성분농도 변화를 산출하고 작물의 기초 생육량을 조사하였다. 각 작물의 기초 생육량 데이터는 오픈스택 클라우드 시스템에서 생성된 가상머신(Virtual machine)에 관계형 데이터베이스를 구축하여 수집 항목별로 분류 저장하였다. 저장된 작물별 배양액의 성분변화와 생육량 데이터는 노드제이에스(Node. js) 웹 프레임워크(Framework)를 통해 매주 수집된 데이터를 가시화하여 제공한다. 클라우드 기반 데이터베이스를 구축을 통하여 배양액 성분 실측치 비교와 작물 생육상황은 사용자 스마트 디바이스(Smart devices)를 활용, 작물종과 배양액 성분을 순차적 선택하고, 각 데이터의 비교 및 분석을 시계열 그래프로 실험 결과를 가시화할 수 있도록 하였다. 본 연구에서 개발한 클라우드 기반 데이터 분석시스템 스마트온실내 수경배양액 성분변화 및 재배 작물의 생육을 정기적으로 모니터링한 실측치를 기반으로 데이터베이스를 구축한 것으로 시설재배지나 인공광 스마트온실 등 다양한 농업현장에서 생육관리를 위하여 활용할 수 있다.

흉부 전산화 단층 촬영 검사 시 발생하는 생식선 차폐 유무에 따른 산란 선량 차이에 관한 연구 (A Study on the Difference of Scattered Rays with or Without Gonadal Shielding During Chest Computed Tomography)

  • 곽종혁;김경립;성현철;김승원;송근성;최민경;이상원
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2021
  • 생식선 차폐를 하지 않았을 때 전부, 양 측부, 후부, 생식선 부위의 산란선을 측정하고 Xenolite nolead Apron(0.35 mm Pb), Xenolite nolead Apron(front 0.35 mm Pb Mix back 0.25 mm Pb, Skirt overlap), Half Apron(0.5 mm Pb)로 차폐 후 각각의 산란 선량을 측정하였다. 흉부 전산화 단층촬영 검사 시 검사 부위의 산란 선량은 272 μSv가 측정되었고, Apron으로 차폐하지 않았을 시에 평균 전부 43 μSv, 좌측부 81 μSv, 우측부 82μSv, 후부 38.8 μSv, Gonad 부위 16 μSv로 측정되었다. Xenolite nolead Apron으로 위쪽 부분만 차폐하고 측정했을 전부 11.2 μSv, 좌측부 43.1 μSv, 우측부 45.3 μSv, 후부 12 μSv, Gonad 부위 5.2 μSv로 측정되었다. Xenolite nolead Apron(Skirt overlap)으로 Pelvis 부위를 360° 감싼 후 선량을 측정하였을 때 전부 5.6 μSv, 좌측부 22.4 μSv, 우측부 15.7 μSv, 후부 6 μSv, Gonad 부위 3.2 μSv로 측정되었다. Xenolite nolead Apron(Skirt overlap)으로 Pelvis 부위를 360° 감싼 후 선량을 측정하였을 때 전부 5.6 μSv, 좌측부 22.4 μSv, 우측부 15.7μSv, 후부 6 μSv, Gonad 위 3.2 μSv로 측정되었다. Half Apron으로 위쪽만 차폐하고 측정했을 때에는 전부 10.7 μSv, 좌측부 42.6 μSv, 우측부 40.6 μSv, 후부 11.3 μSv, Gonad부위 4.7 μSv로 측정되었다. 골반 부위를 360° 차폐하는 방법이 80% 이상 선량 감소를 보였고, 전부 차폐 시 70% 이상의 선량 감소 효과를 보였으며 모든 전산화 단층 촬영 검사에 있어 피폭선량 경감을 위한 연구와 차폐 가능한 장비를 활용하는 다양한 기법에 관한 지속적인 연구가 필요하리라 사료된다.

건강한 성인에서 가속도계로 측정한 신체활동과 맥파전달속도 및 상완-발목 간 혈압비에 기반한 동맥경화지표와의 관계 (Association between physical activity measured using an accelerometer and arterial stiffness based on pulse wave velocity and ankle-brachial index in healthy adults)

  • 이현주;박계월;전하연;곽지연;김은경
    • Journal of Nutrition and Health
    • /
    • 제55권4호
    • /
    • pp.506-520
    • /
    • 2022
  • 본 연구에서는 심혈관 질환의 위험 인자인 고혈압, 이상지질혈증 및 당뇨병이 없는 건강한 성인 남·녀를 대상으로 3축 가속도계를 이용하여 일주일간의 평소 신체활동량을 평가하고 동맥경화지표와의 연관성을 알아보고자 하였다. 가속도계를 이용한 신체활동 측정 결과, WHO 신체활동지침 준수율은 29.9%, 좌식 행동에 소비한 시간은 531.1 min/day, 저강도 활동에 소비한 시간은 281.4 min/day, 중·고강도 활동에 소비한 시간은 36.2 min/day 이였다. 활동 수준이 다른 두 군의 신체활동을 비교한 결과, CPM, 중·고강도 활동에 소비한 시간, 중·고강도 활동을 10분 이상 지속한 횟수 및 시간은 활동군이 비활동군에 비해 유의하게 높았다. 좌식 행동에 소비한 시간은 활동군이 비활동군에 비해 유의하게 낮은 반면 좌식 행동 패턴 및 baPWV와 ABI는 두 군 간에 유의한 차이가 없었다. 그러나 여자에서는 좌식 행동을 60분 이상 지속하는 횟수와 baPWV 간에 양의 상관관계가 나타났으며 좌식 행동을 50분 이상 지속하는 횟수와 ABI 간에 음의 상관관계를 보였고, 저강도 활동에 소비한 시간과 ABI 간에는 양의 상관관계를 보였다. 이는 좌식 행동을 50분 이상 지속하는 횟수가 많을수록 동맥경화 및 말초 동맥질환의 위험이 높고 저강도 활동에 소비한 시간이 많을수록 말초동맥질환의 위험이 낮음을 보여주었다. 향후 동맥경화 예방을 위한 지침 마련을 위해 다양한 연령대의 건강한 성인을 대상으로 신체활동과 함께 식품 및 영양섭취 현황, 식사 패턴, 음주 행태 등 동맥경화와 관련된 요인들이 포함된 연구의 필요성을 제안하는 바이다.

농촌지역 주민들의 구취실태와 유발요인 (Halitosis and Related Factors among Rural Residents)

  • 이영옥;홍정표;이태용
    • Journal of Oral Medicine and Pain
    • /
    • 제32권2호
    • /
    • pp.157-175
    • /
    • 2007
  • 본 연구는 농촌지역 주민들의 구취실태를 파악하고 구취에 관련된 요인을 알아봄으로써 구취예방 및 효율적인 구취제거 방안을 마련하는데 기초 자료를 제공하고자 일부 농촌지역의 주민 293명을 대상으로 2006년 1월 4일부터 1월 21일까지 면접설문조사(구강위생관리 행태, 구취관련 질병력, 구취실태), 구취측정, 구강검사, 치아우식활성검사(스나이더검사, 타액분비율검사, 타액완충능검사)를 실시한 결과 다음과 같은 결론을 얻었다. 1. 잇솔질 횟수는 1일 2회가 46.1 %로 가장 많았고, 여자가 남자보다 잇솔질 횟수가 많았다. 매일 혀솔질을 하는 군은 25.6%이었고, 보조 구강위생용품을 사용하는 군은 9.2 %이었다. 2. 평상시 구취를 자각하고 있는 사람은 62.5 %이었고, 구취를 가장 심하게 자각하는 시기는 기상 후가 72.7 %, 구취를 자각하는 부위는 잇몸에서 23.0 %, 구취의 유형으로는 구린 냄새가 37.2 %로 높게 나타났다. 3. 구취측정 결과 OG는 50 ppm미만이 54.3 %, $50{\sim}100ppm$ 범위에 41.6 %로 나타났고, $NH_3$$20{\sim}60ppm$ 범위에 52.6 %로 가장 높았다. 4. 구취관련 질병력별 OG는 치아우식증으로 인한 식편압입, 당뇨병과 구취에 대한 가족력군에서 $50{\sim}100ppm$ 범위에 유의하게 높았으며, $NH_3$는 호흡기계 질환군에서 유의한 차이가 있었다. 5 평상시 구취 자각정도별 OG는 '냄새가 나지 않는다'는 군과 '가끔 냄새가 난다'는 군에서 50 ppm 미만에 각각 55.9 %, 57.5 %로 나타났고, '본인이 느낄 정도로 항상 냄새가 난다'는 군과 '항상 심하게 냄새가 난다'는 군에서 $50{\sim}100ppm$ 범위에 각각 52.0 %, 63.6 %로 높게 나타났으며, $NH_3$는 모두 $20{\sim}60ppm$ 범위에 높게 나타났다. 6. 구강검사별 OG는 치수노출치와 식편압입이 많을수록, 설태지수가 높아질수록 $50{\sim}100ppm$ 범위에 OG값이 증가되었고, $NH_3$는 보철치가 많을수록, 설태지수가 높아질수록 유의하게 증가되었으며, 하악 국소의치군에서 60 ppm 이상으로 유의하게 증가되었다. 7. 스나이더검사는 고도활성이 43.0 %로 가장 높았고, 산 생성균의 활성이 높을수록 OG값이 증가되었다. 자극성 타액분비율 검사는 8.0 ml 이하에서 62.5 %로 가장 높았고, 타액분비율이 많을수록 OG값이 감소된 분포를 보였으며, 타액완충능검사는 0.1N 유산용액의 방울 수가 $6{\sim}10$ 방울에서 58.7 %로 가장 높았고, 타액완충능이 증가될수록 OG값이 냄새를 느끼지 못하는 50 ppm 미만에서 증가되었다. 8. 구강환경과 구취와의 상관관계에서 OG는 타액분비율, 보철치와 음의 상관관계를, 치수노출치, 충전치, 현존치, 설태량, 식편압입과 양의 상관관계를 보였으며, $NH_3$는 우식치와 음의 상관관계를, 보철치, 잇솔질 횟수와 양의 상관관계를 보였다. 9. 다중회귀분석 결과에서 OG에 영향을 주는 요인으로는 여자, 치수노출치, 보철치, 식편압입, 타액분비율, 설태지수, 스나이 더검사의 고도활성이 선정되었고 이들의 설명력은 45.1 %이었으며, NH3에 영향을 주는 요인으로는 여자, 치수노출치, 설태지수, 보철치가 선정되었으며 이들의 설명력은 6.6 %이었다. 이상의 결과를 볼 때, 조사대상 농촌지역 주민들의 구취실태는 구강환경 및 구취관련 요인, 치아우식활성검사의 스나이더 검사, 타액분비율검사와 밀접한 관련이 있음을 시사한다. 따라서 이들 주민들의 구취예방을 위해서는 식후에 올바른 잇솔질 방법 및 혀솔질과 더불어 보조 구강위생용품을 사용하여 식편압입과 설태제거를 해야 할 필요성이 강조된다. 구취의 원인과 그 성분은 매우 복잡하고 다양하므로 개인별 구취발생 요인을 정확하게 분석하기 위해서는 추후 계속적이고, 체계적인 연구가 필요하며, 보건(지)소의 치과위생사를 활용하여 지역사회 주민들에게 계속적인 구강보건교육 프로그램이 제공되어야 한다고 생각된다.

두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발 (Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy)

  • 심재구;송기원;김진만;박명환
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.43-50
    • /
    • 2014
  • 두경부암 환자의 헤드 홀더를 사용하는 경우 모의 치료 시 환자는 테이블 위에 위치하지만, 방사선 치료를 시행하는 경우 헤드 홀더를 치료 테이블에 걸쳐서 사용하기 때문에 체중 및 여러 가지 요소로 인한 기하학적 불일치로 상, 하, 좌, 우 및 처짐의 현상이 발생할 수 있다. 이러한 환자 Set-Up의 재현성의 불일치를 개선하기 위해 두경부암 전용 헤드 홀더를 자체 고안하여 제작 및 개발하여 유용성을 평가하였다. Alderson Rando Phantom을 이용하여 전산화단층촬영장치(High Advantage, GE, U.S.A)를 통해 이미지를 획득하였고, 광자선 4MV 세기변조 방사선치료(IMRT) 방식을 적용하여 최적화된 치료 계획을 실시하였다. 선형가속기(21EX, Varian, U.S.A)를 이용하여 모의 치료와 동일한 상태에서 환자를 set-up한 후 에 치료기에 장착된 CBCT를 이용하여 각각의 무게(0,15,30Kg)의 차이를 통해 교정 전, 후 X, Y, Z축의 오차를 5회 반복 측정한 결과는 다음과 같다. 0Kg에서 $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0mm으로 나타났고, 교정 후에는 $0.2{\pm}0.8mm$, $0.4{\pm}0.5mm$, 0으로 나타났다. 15Kg에서 교정 전,후 오차는 $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.2{\pm}0.4mm$$0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$로 나타났다. 30Kg에서 교정 전,후 오차는 $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$$0.6{\pm}0.54mm$, $1{\pm}0mm$, $0.6{\pm}0.5mm$로 나타났다. 각각의 교정 전,후의 통계적으로 분석한 결과 15Kg인 경우 Z축에서 p<0.034, 30Kg인 경우 Y, Z축에서 p<0.038, p<0.041 로 유의한 결과를 나타냈다. 두경부암 전용 방향 조절 장치 헤드 홀더가 환자의 set-up오차를 줄여주는 역할을 해주는 것으로 나타났다. 또한 오차를 줄여줌으로써 환자의 재현성이 향상되어 보다 정밀하고 정확한 방사선 치료를 구현할 수 있을 것으로 사료된다.

TV 시청률과 마이크로블로그 내용어와의 시간대별 관계 분석 (Analysis of the Time-dependent Relation between TV Ratings and the Content of Microblogs)

  • 최준연;백혜득;최진호
    • 지능정보연구
    • /
    • 제20권1호
    • /
    • pp.163-176
    • /
    • 2014
  • 소셜미디어 확산으로 많은 사용자들이 SNS를 통해 자신의 생각과 의견을 표출하며 다른 사용자들과 상호작용하고 있다. 특히 트위터와 같은 마이크로블로그는 짧은 문장을 통해 영화, TV, 사회 현상 등과 같은 공통의 주제에 대해 많은 사람이 즉각적으로 의견을 표출하고 교환하는 플랫폼의 역할을 수행하고 있다. TV방송 프로그램에 대해서도 의견과 감정을 마이크로블로그를 통해 표출하고 있는데, 본 연구에서는 마이크로블로그의 내용과 시청률과의 관계를 살펴보기 위해, 지난 공중파 방송 프로그램에 대한 트윗을 수집하고 부적절한 트윗들을 제거한 후 형태소 분석을 수행하였다. 추출된 형태소뿐 아니라 이모티콘, 신조어 등 사용자가 입력한 모든 단어들을 후보 자질로 삼아 시청률과의 상관관계를 분석하였다. 실험을 위해 2013년 1월부터 10개월간의 예능프로그램 트윗의 데이터를 수집하여 전국 시청률 데이터와 비교 분석을 수행하였다. 트윗의 발생량은 일주일 중 방송된 요일에 가장 많았으며, 특히 방송시간 부근에서 급격히 증가하는 모습을 보였다. 이것은 전국에 동시간에 방송되는 공중파 프로그램의 특성상 공통된 관심 주제를 제공하기 때문에 나타나는 현상으로 여겨진다. 횟수 기반 자질로 방송 일의 총 트윗 수와 리트윗 수, 방송시간 중의 트윗 수와 리트윗 수와 시청률과의 상관 관계를 분석하였으나 모두 낮은 상관 계수를 나타냈다. 이것은 단순한 트윗 발생 빈도는 방송 프로그램의 만족도 또는 시청률을 제대로 반영하고 있지 못함을 의미한다. 내용 기반 자질로 추출한 단어들 중에는 높은 상관관계를 보여주는 단어들이 발견되었으며, 표준어가 아닌 이모티콘과 신조어 중에도 높은 상관관계를 보여주는 자질이 나타났다. 또한 방송시작 전과 후에 따라 상관계수가 높은 단어가 상이함을 발견하였다. 매주 같은 시간에 방송되는 TV 프로그램의 특성상, 방송을 기다리고 기대하는 내용의 트윗과 방송 후 소감을 표현하는 트윗의 내용에 차이가 존재하였다. 이러한 분석결과는 단어에 따라 시청률과 연관성이 높은 시간대가 달라짐을 의미하며, 시청률을 측정하고자 할 때 각 단어들의 시간대를 고려해서 사용해야 함을 의미한다. 본 연구에서 제안한 방법은 기존의 표본 추출을 통해 이루어지는 TV 시청률 측정을 보완할 수 있는 방법에 활용할 수 있으리라 기대된다.

두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가 (Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer)

  • 백민규;김민우;하세민;채종표;조광섭;이상봉
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.7-15
    • /
    • 2020
  • 목 적: 현대 방사선치료기술에서 종양표적위치 및 정상장기에 정확한 선량을 전달하기 위해 여러 방법의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)가 사용되고 있으며 그 중 선형가속기에 장착된 CBCT(Cone Beam Computed Tomography, CBCT)와 이외 장치인 ExacTrac(ExacTrac X-ray System)이 있다. 두 시스템을 비교한 이전 연구들에서는 Offline-review 이용하여 후향적으로 팬텀 및 환자의 Set-up 오차를 분석하거나 X, Y, Z 축과 하나의 회전방향(Couch Rotation)으로만 연구되어졌다. 본 연구에서는 Head and Neck Cancer 환자를 대상으로 CBCT와 ExacTrac을 이용하여 한 치료중심센터에서 각각 6 DoF(Degree Of Freedom) IGRT를 시행한 후, 두 IGRT 장비에서 나타난 팬텀 및 환자의 Set-up 오차, 환자 Set-up에 걸리는 시간, 노출 방사선량의 비교를 통해 유용성을 평가하고자 한다. 대상 및 방법: Rando Phantom을 이용하여 환자 움직임을 배제한 상태의 Set-up 오차 평가와 Head and Neck Cancer 환자의 Set-up 오차 값 두 가지 경우로 나누어 획득하였다. 노출 방사선량 평가는 유리선량계로 하였다. 환자 Set-up 후 IGRT 시행하는데 소요되는 시간을 평가하기 위해 Head and Neck Cancer 환자 11명을 대상으로 하였다. 총 치료기간동안 환자 당 평균 10회의 CBCT와 ExacTrac 영상을 동시에 얻었고, 관심영역지정(Region Of Interest, ROI) 설정 후 6D 온라인 자동위치교정(Online Automatching) 값의 차를 6개의 축(Translation group: SI, AP, LR; Rotation group: Pitch, Roll, Rtn)으로 각각 계산하였다. 결 과: Phantom과 환자에서 Set-up 오차는 Translation group에서 1mm 미만, Rotation group에서 1.5° 미만의 차이가 보였으며, Rtn 값을 제외한 다른 모든 축의 RMS 값이 1mm, 1° 미만으로 나타났다. 각 시스템에서 최종적으로 Set-up 오차 교정까지 걸리는 시간은 CBCT를 이용한 IGRT에서는 평균 256±47.6sec, ExacTrac을 이용 시 평균 84±3.5sec로 각각 나타났다. 1회 치료 당 IGRT에 의한 방사선 노출선량은 Head and Neck 부위 7곳의 측정위치 중 Oral Mucosa에서 CBCT와 ExacTrac이 각각 2.468mGy, 0.066mGy로 상대적으로 ExacTrac에 비해 피폭선량이 37배 높게 측정되었다. 결 론: CBCT와 ExacTrac 두 시스템 간의 6D 온라인 자동위치교정을 통해 Set-up 오차는 두 시스템의 자체적인 Systematic error 뿐 아니라, 환자 움직임(Random error)를 포함한 Set-up 오차가 1mm, 1.02° 미만으로 나타났다. 이는 본원에서 Head and Neck IMRT 치료 시 PTV Margin이 3mm이라는 것을 고려했을 때, 이 오차범위는 합리적으로 사료된다. 하지만 치료기간 동안 환자체중변화로 인한 따른 표적, 손상위험장기의 변화를 고려했을 때 CBCT와 적절히 병용하여 사용하는 것이 좋을 것으로 사료된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF