Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

Pose Calibration of Inertial Measurement Units on Joint-Constrained Rigid Bodies (관절체에 고정된 관성 센서의 위치 및 자세 보정 기법)

  • Kim, Sinyoung;Kim, Hyejin;Lee, Sung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.19 no.4
    • /
    • pp.13-22
    • /
    • 2013
  • A motion capture system is widely used in movies, computer game, and computer animation industries because it allows for creating realistic human motions efficiently. The inertial motion capture system has several advantages over more popular vision-based systems in terms of the required space and cost. However, it suffers from low accuracy due to the relatively high noise levels of the inertial sensors. In particular, the accelerometer used for measuring gravity direction loses the accuracy when the sensor is moving with non-zero linear acceleration. In this paper, we propose a method to remove the linear acceleration component from the accelerometer data in order to improve the accuracy of measuring gravity direction. In addition, we develop a simple method to calibrate the joint axis of a link to which an inertial sensor belongs as well as the position of a sensor with respect to the link. The calibration enables attaching inertial sensors in an arbitrary position and orientation with respect to a link.

Experimental validation of Kalman filter-based strain estimation in structures subjected to non-zero mean input

  • Palanisamy, Rajendra P.;Cho, Soojin;Kim, Hyunjun;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.489-503
    • /
    • 2015
  • Response estimation at unmeasured locations using the limited number of measurements is an attractive topic in the field of structural health monitoring (SHM). Because of increasing complexity and size of civil engineering structures, measuring all structural responses from the entire body is intractable for the SHM purpose; the response estimation can be an effective and practical alternative. This paper investigates a response estimation technique based on the Kalman state estimator to combine multi-sensor data under non-zero mean input excitations. The Kalman state estimator, constructed based on the finite element (FE) model of a structure, can efficiently fuse different types of data of acceleration, strain, and tilt responses, minimizing the intrinsic measurement noise. This study focuses on the effects of (a) FE model error and (b) combinations of multi-sensor data on the estimation accuracy in the case of non-zero mean input excitations. The FE model error is purposefully introduced for more realistic performance evaluation of the response estimation using the Kalman state estimator. In addition, four types of measurement combinations are explored in the response estimation: strain only, acceleration only, acceleration and strain, and acceleration and tilt. The performance of the response estimation approach is verified by numerical and experimental tests on a simply-supported beam, showing that it can successfully estimate strain responses at unmeasured locations with the highest performance in the combination of acceleration and tilt.

A 24 GHz I/Q LO Generator for Heartbeat Measurement Radar System (심장박동 측정 레이더를 위한 24GHz I/Q LO 발생기)

  • Yang, Hee-Sung;Lee, Ockgoo;Nam, Ilku
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.66-70
    • /
    • 2016
  • This paper presents an 24 GHz I/Q LO generator for a heartbeat measurement radar system. In order to improve the mismatch performance between I and Q LO signals against process variation, a 24 GHz I/Q LO generator employing a low-pass phase shifter and a high-pass phase shifter composed of inductors and capacitors is proposed. The proposed 24 GHz I/Q LO generator consists of an LO buffer, a low-pass phase shifter and a high-pass phase shifter. It was designed using a 65 nm CMOS technology and draws 8 mA from a 1 V supply voltage. The proposed 24 GHz I/Q LO generator shows a gain of 7.5 dB, a noise figure of 2.3 dB, 0.1 dB gain mismatch and $4.3^{\circ}$ phase mismatch between I and Q-path against process and temperature variations for the operating frequencies from 24.05 GHz to 24.25 GHz.

Analysis and Compensation of Current Measurement Error in Digitally Controlled AC Drives (디지털 제어 교류 전동기 구동시스템의 전류 측정 오차 해석 및 보상)

  • 송승호;최종우;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.462-473
    • /
    • 1999
  • This paper addresses the current measurement issue of all digital field oriented control of ac motors. The p paper focuses on the effect of low-pass filter and also on the sampling of the fundamental component of the m motor current. The low-pass filter, which suppresses the switching noise of the motor current, introduces v variable phase delay according to the current ripple frequency. It is shown that the current sampling error c consists of the fundamental component and high frL'quency ripple components. In this paper, the dependency of t this current sampling e$\pi$or on the reference voltage vector is investigated analytically and a sampling technique i is proposed to minimize the error. The work is based on the three phase symmetry pulse width modulation l inverter driving an induction machine. With this technique, the bandwidth of current regulator can be extended t to the limit given by the switching frequency of the inverter and more precise torque regulation is possible.

  • PDF

UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear (가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법)

  • Song Won-Pyo;Kim Jung-Bae;Kim Min-So;Jung Jae-Ryong;Park Seung-Jae;Ko Heui-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

Development of Local-Exposure Systems for In Vivo Studies at Mobile-Phone Frequency Bands (이동통신 주파수 대역에서의 동물 실험용 국부 노출 장치 개발)

  • Ko Chea-Ok;Park Min-Young;Doh Hyeon-Jeong;Kim Jeong-Lan;Jung Ki-Bum;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.451-460
    • /
    • 2006
  • We have designed local exposure systems for long-time mice experiments in PCS and cellular frequency band(PCS: 1,762.5 MHz, cellular: 848.5 MHz). The fabricated systems are local exposure systems of carousel type, and 40 mice can be exposed at a time. In order not to give extra stress to the mice ender experiment, the systems were fabricated to meet the environmental conditions such as illumination, ventilation, noise etc. SAR measurement was performed using a temperature probe. Measurements at 3 points in the head of mouse cadaver and solid phantom were made, and it has been confirmed that the measurement results are in good agreement with the simulation results in the real exposure environment. The exposure systems are currently used for long-term mice experiments.

Design of A Power Oscillator Using Spiral Resonator (나선형 공진기를 이용한 고출력 발진기의 설계)

  • Koo, Ja-Kyung;Lim, Jong-Sik;Lee, Jun;Lee, Jae-Hoon;Han, Sang-Min;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3866-3872
    • /
    • 2010
  • This paper presents a design of high power oscillator using a spiral resonator and high power transistor with measurement. Even lots of drawbacks are known in design of oscillators using high power transistors, the spiral resonator is adopted because it has relatively high Q out of planar resonators. The designed power oscillator at 1.8GHz is fabricated and tested. Measurement shows the obtained output power is 23.5dBm at 1.74GHz with -146.76dBc/Hz of phase noise at 1MHz offset. In addition, it is illustrated that the frequency stability is excellent with the shift less than 1MHz and the measured maximum output power is around 24dBm when the bias voltages are adjusted.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Bone Region Extraction by Dual Energy X-ray Absorbtion Image Decomposition (Dual Energy X-ray 흡수 영상의 분해를 통한 뼈 영역 추출)

  • Kwon, Ju-Won;Cho, Sun-Il;Ahn, Young-Bok;Ro, Yong-Man
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1233-1241
    • /
    • 2009
  • Over the 50 percents of women who are older than 45 years have osteoporosis. Because people hardly recognize this disease by themselves, the researches that measure bone mineral density have been doing widely to detect osteoporosis in the early stage. The most widely used methods for bone mineral density measurement are based on the X-ray imaging. Among them, DEXA(Dual-energy X-ray Absorptiometry) imaging is one of the important methods in bone mineral density measurement. DEXA images are useful methods to increase diagnosis efficiency by reducing anatomic noise as two images obtained from two different energy levels. However, it has some problems to a calibration parameter determined by the heuristic method for bone extraction. In this paper, we propose the method to extract bone in DEXA image using calibration parameter based on anatomic attenuation coefficient. The experimental results reveal that the proposed method is effective.