• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.033 seconds

Consideration of stress and load state changes using measurement results of a shield tunnel in operation (운용 중 쉴드터널 계측결과를 이용한 응력 및 하중상태 변화추이 고찰)

  • Yong Hag Kim;Kook Hwan Cho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.5
    • /
    • pp.463-476
    • /
    • 2024
  • The shield TBM method can eliminate environmental hazards such as noise and vibration, and is environmentally friendly and allows safe tunnel construction even in soft ground conditions, but there are many restrictions on its application due to its high construction costs compared to the NATM. Therefore, in order to increase the applicability of the shield TBM method, it is necessary to ensure economic efficiency by reducing construction costs, and it is very important to reduce segment construction costs, which account for the largest proportion of shield TBM tunnel construction costs at about 35 to 40%. As part of this, this paper considers the changes in segment stress during tunnel construction and operation, tunnel external load conditions, etc. through analysis of long-term measurement data of shield TBMs in Japan, which has abundant experience in shield TBM construction, and compares and analyzes the differences between predicted values at the design stage and measured values during operation. Through this, we study improvements to ensure segment economic efficiency at the shield TBM design stage.

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.

Measurement of Vertical-Directional DTV Signal Level Using a Multi-Copter (멀티콥터를 이용한 수직방향 DTV 신호 레벨 측정)

  • Park, Hyung-Do;Lim, Sol;Kim, Dae Jin
    • Journal of Broadcast Engineering
    • /
    • v.19 no.3
    • /
    • pp.372-384
    • /
    • 2014
  • DTV field tests have been performed to measure field strength and to check reception ratio on indoor and outdoor sites. They use an antenna of 9m to measure DTV signal in case of outdoor measurement on the road. Modern skyscrapers require the analysis of vertical-directional wave propagation by measuring vertical-directional DTV signal. Even if the field strength is above the reception threshold of $43dB{\mu}V/m$, the reception is impossible in case of strong multi-path or high impulse noise. So, vertical-directional field measurement is essential in environment of tall buildings. In this paper, we developed an octo type multi-copter to measure vertical-directional DTV signal level. A compact and portable DTV signal level meter, an antenna, a microwave transmitter for data transmission, and a recording equipment are equipped in the multi-copter. Three different sites are selected to test the measurement system. Developed measurement system using the multi-copter is very useful in measuring vertical-directional DTV signal, especially in apartments, non-accessible area by vehicles, and forbidden areas.

The Development of Topographic Feature Extraction Method by use of the Seafloor Curvature Measurement (곡률 계산에 의한 해저면 지형요소 추출 기법 개발)

  • Kim, Hyun-Sub;Jung, Mee-Sook;Park, Cheong-Kee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.163-172
    • /
    • 2007
  • A seafloor curvature measurement method was developed to extract redundant topographic features from the multi-beam bathymetry data, and then applied to the data of abyssal plain area in the Pacific. Any seafloor might be modeled to a quadratic surface determined in a linear least squares sense, and its curvature could be derived from the eigen values related with quadratic model parameters. The curvature's magnitude as well as polarity showed distinct relationship with geometric characteristics of the seafloor like as ridge and valley. From the investigation of curvature's variation with the number of data in the quadratic surface, the optimal size of data aperture could be applied to real bathymetry data. The application to real data also required the determination of the accompanying threshold values to cope with corresponding topographic features. The calculation method of previous studies were reported to be sensitive to the background noise. The improved curvature measurement method, incorporating the sum of eigen values has reduced unwanted artifacts and enhanced ability to extract lineament features along strike direction. The result of application shows that the curvature measurement method is effective tool for the estimation of a possible mining area in the seamount free abyssal hill area.

Linewidth Reduction of a Yellow Laser by a Super-cavity and the Measurement of the Cavity Finesse (초공진기를 이용한 노란색 레이저의 선폭 축소 및 초공진기의 예리도 측정)

  • Lee, Won-Kyu;Park, Chang-Yong;Park, Sang-Eon;Ryu, Han-Young;Yu, Dai-Hyuk;Mun, Jong-Chul;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.3
    • /
    • pp.123-128
    • /
    • 2010
  • Sum frequency generation was utilized to obtain a yellow laser with the wavelength of 578.4 nm for a probe laser of an Yb lattice clock. The output of an Nd:YAG laser with wavelength of 1319 nm and that of an Yb-fiber laser with wavelength of 1030 nm were passed through a waveguided periodically-poled lithium niobate (WG-PPLN) for sum frequency generation. It is required that the probe laser has a linewidth of the order of 1 Hz to fully resolve the Yb lattice clock transition. Thus, the linewidth of the probe laser was reduced by stabilizing the frequency to a super-cavity. This was made of ULE with a low thermal expansion coefficient, and was mounted on an active vibration-isolation table at the optimal point for the reduced sensitivity to vibration. Also, this was installed in a vacuum chamber, and the temperature was stabilized to 1 mK level. This system was installed in an acoustic enclosure to block acoustic noise. The finesse of the super-cavity was measured to be 380 000 from the photon life time of the cavity.

A preliminary study on the measurement method for determining the absorption coefficient of sound barrier panels (방음판의 흡음률 측정방법 제안을 위한 기초 연구)

  • Yang Ki Oh;Ha Geun Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.152-160
    • /
    • 2023
  • Sound barrier walls are the most basic way to cope with noise problems in urban residential environments. The most important acoustic function of sound insulation board is represented by sound transmission loss and sound absorption coefficient. However, Korea has not yet established a standard for measuring the sound absorption rate of sound insulation boards. In addition, even in the European standard, where the overall acoustic standard of soundproofing boards has already been established, the sound absorption rate is applied only to the standard for measuring the sound absorption rate of general building finishing materials, and a separate measurement method considering the characteristics of soundproof walls and soundproofing boards is not presented. The sound absorption coefficient should be evaluated by summing up the energy absorbed into the material as well as the energy transmitted through the material, but the current European standard has a problem in that the transmitted sound energy is not taken into account. In this paper, we reviewed the sound absorption coefficient measurement standards of sound insulation boards currently being presented, and verified the difference between the results and the new measurement method considering transmission sound for sound insulation boards actually used in Korea.

A Study on the Measurement of Respiratory Rate Using Image Alignment and Statistical Pattern Classification (영상 정합 및 통계학적 패턴 분류를 이용한 호흡률 측정에 관한 연구)

  • Moon, Sujin;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.10
    • /
    • pp.63-70
    • /
    • 2018
  • Biomedical signal measurement technology using images has been developed, and researches on respiration signal measurement technology for maintaining life have been continuously carried out. The existing technology measured respiratory signals through a thermal imaging camera that measures heat emitted from a person's body. In addition, research was conducted to measure respiration rate by analyzing human chest movement in real time. However, the image processing using the infrared thermal image may be difficult to detect the respiratory organ due to the external environmental factors (temperature change, noise, etc.), and thus the accuracy of the measurement of the respiration rate is low.In this study, the images were acquired using visible light and infrared thermal camera to enhance the area of the respiratory tract. Then, based on the two images, features of the respiratory tract region are extracted through processes such as face recognition and image matching. The pattern of the respiratory signal is classified through the k-nearest neighbor classifier, which is one of the statistical classification methods. The respiration rate was calculated according to the characteristics of the classified patterns and the possibility of breathing rate measurement was verified by analyzing the measured respiration rate with the actual respiration rate.

Aspects on Nonuniqueness and Instability Inherent in Inverse Scattering Problems

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.2
    • /
    • pp.133-139
    • /
    • 2003
  • The nonuniqueness of a mathematically rigorous solution to 2-dimensional inverse scattering problems is explained in a limiting view of the numerical calculations based on the spectral-domain moment method. It is illustrated that its theoretical uniqueness cannot be assured even by performing additional measurements of the scattered fields not only along multiple lines but also with angular/frequency-diversities. In a real situation, however, computational error and measurement noise are inevitable. Those limitations render it meaningless to controvert the existence of a theoretically rigorous solution. Hence the most practical issue is how to remedy the instability of its practically approximate solution.

Design of the Detection Circuitry for the Characteristics of Micromachined Vibrating Gyroscope (미세가공 진동형 자이로스코프의 특성 감지 회로의 설계에 관한 연구)

  • U, Yeong-Sin;Byeon, Gwang-Gyun;Seo, Il-Won;Seong, Man-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.687-692
    • /
    • 1999
  • A new technique to measure low level capacitance variations of the gyroscope is proposed and verified by computer simulation. It is based on the new CV(capacitance-voltage) converter circuit biased by dc current source and the peak detector without low pass filter. The CV converter biased by dc current source provides good signal-to-noise ratio and this setup of the detection circuitry without low pass filter makes it possible to provide short settling time, that is, higher speed of measurement and wide operation range if only a few parameters are adjusted. The key parameters that affect the performance of the detection circuitry are illustrated and computer simulation results are presented. The demonstrated detection circuitry shows linear response from 10 fF to 130 fF at 10 kHz and shows good linearity.

  • PDF

A New Algorithm to Estimate Urine Volume from 3D Ultrasound Bladder Images (3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘)

  • Cho, Tae Sik;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • For the patients with bladder dysfunction, measurement of urine volume inside the bladder is very critical to avoid bladder failure. In measuring urine volume inside a bladder, low-resolution 3D ultrasound images are widely used. However, urine volume estimation from 3D ultrasound images is prone to big errors and inconsistency because of low spatial resolution and low signal-to-noise ratio of ultrasound images. We developed a new robust volume estimation algorithm which is not computationally expensive. We tested the algorithm on a lab-built ultrasound bladder phantom and volunteers. The average error rate of the human bladder volume estimation was 5.9% which was better than the commercial machine.