• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.03 seconds

Structural identification based on substructural technique and using generalized BPFs and GA

  • Ghaffarzadeh, Hosein;Yang, T.Y.;Ajorloo, Yaser Hosseini
    • Structural Engineering and Mechanics
    • /
    • v.67 no.4
    • /
    • pp.359-368
    • /
    • 2018
  • In this paper, a method is presented to identify the physical and modal parameters of multistory shear building based on substructural technique using block pulse generalized operational matrix and genetic algorithm. The substructure approach divides a complete structure into several substructures in order to significantly reduce the number of unknown parameters for each substructure so that identification processes can be independently conducted on each substructure. Block pulse functions are set of orthogonal functions that have been used in recent years as useful tools in signal characterization. Assuming that the input-outputs data of the system are known, their original BP coefficients can be calculated using numerical method. By using generalized BP operational matrices, substructural dynamic vibration equations can be converted into algebraic equations and based on BP coefficient for each story can be estimated. A cost function can be defined for each story based on original and estimated BP coefficients and physical parameters such as mass, stiffness and damping can be obtained by minimizing cost functions with genetic algorithm. Then, the modal parameters can be computed based on physical parameters. This method does not require that all floors are equipped with sensor simultaneously. To prove the validity, numerical simulation of a shear building excited by two different normally distributed random signals is presented. To evaluate the noise effect, measurement random white noise is added to the noise-free structural responses. The results reveal the proposed method can be beneficial in structural identification with less computational expenses and high accuracy.

A study on the improvement of cavitation inception speed for controllable pitch propeller in the actual warship (실선관측에 의한 가변추진기의 캐비테이션 초생속도 향상에 관한 연구)

  • Lim, Yong-Su;Jo, Kwan-Jun;Yeun, Je-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1170-1174
    • /
    • 2014
  • If cavitation occurs in propeller, it generates vibration and noise accordingly which results in low efficiency of propeller. It's important to increase cavitation inception speed(CIS) since the noise of cavitation increases significantly from the beginning of cavitation. This paper describes the result of actual observation and measurement onboard ship with controllable pitch propeller(CPP), so as to verify the first occurrence phenomenon of cavitation. The research suggests new type of controllable pitch propeller with improved CIS at the bolt as it started with bolt cavitation as result of observation. It's not found bolt cavitation on the CPP proposed in this paper, furthermore its CIS is increased approximately by 4.5 knots than the existing CPP. The result of the research can be used for development of low-noise CPP and improving performance of CIS.

Robust Speech Reinforcement Based on Gain-Modification incorporating Speech Absence Probability (음성 부재 확률을 이용한 음성 강화 이득 수정 기법)

  • Choi, Jae-Hun;Chang, Joon-Hyuk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.175-182
    • /
    • 2010
  • In this paper, we propose a robust speech reinforcement technique to enhance the intelligibility of the degraded speech signal under the ambient noise environments based on soft decision scheme incorporating a speech absence probability (SAP) with speech reinforcement gains. Since the ambient noise significantly decreases the intelligibility of the speech signal, the speech reinforcement approach to amplify the estimated clean speech signal from the background noise environments for improving the intelligibility and clarity of the corrupted speech signal was proposed. In order to estimate the robust reinforcement gain rather than the conventional speech reinforcement method between speech active periods and nonspeech periods or transient intervals, we propose the speech reinforcement algorithm based on soft decision applying the SAP to the estimation of speech reinforcement gains. The performances of the proposed algorithm are evaluated by the Comparison Category Rating (CCR) of the measurement for subjective determination of transmission quality in ITU-T P.800 under various ambient noise environments and show better performances compared with the conventional method.

Acoustical Similarity for Small Cooling Fans Revisited (소형 송풍기 소음의 음향학적 상사성에 관한 연구)

  • 김용철;진성훈;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF

Assessment of dose effects on image quality at chest computed radiography (흉부 CR 영상에서 선량이 화질에 미치는 영향에 대한 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.421-426
    • /
    • 2011
  • This research was accomplished to assess dose effects on image quality at computed radiography (CR). The ultimate target of the research was finding optimized exposure that provides necessary image quality for the clinical chest diagnosis. Modulation transfer function (MTF), normalized noise power spectrum (NNPS), and Noise equivalent quanta (NEQ) corresponding to the different doses were measured for the assessment of image quality. The preparation of "edge test device" used in MTF measurement and experimental geometry setup were followed by the recommendations of International Electrotechnical Commission (IEC). The experimental results show the necessary image quality can be achieved even at a half of the automatic exposure control (AEC) setting dose for chest diagnosis. It means that the patient exposure can be reduced dramatically by using optimized dose.

A Substrate Resistance and Guard-ring Modeling for Noise Analysis of Twin-well Non-epitaxial CMOS Substrate (Twin-well Non-epitaxial CMOS Substrate에서의 노이즈 분석을 위한 Substrate Resistance 및 Guard-ring 모델링)

  • Kim, Bong-Jin;Jung, Hae-Kang;Lee, Kyoung-Ho;Park, Hong-June
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.32-42
    • /
    • 2007
  • The substrate resistance is modeled to estimate the performance degradation of analog circuits by substrate noise in a $0.35{\mu}m$ twin-well non-epitaxial CMOS process. The substrate resistance model equations are applied to the P+ guard-ring isolation structure and a good match was achieved between measurements and models. The substrate resistance is divided into four types and a semi-empirical model equation is obtained for each type of substrate resistance. The rms(root-mean-square) error of the substrate resistance model is below 10% compared with the measured resistance. To apply this substrate resistance model to the P+ guard ring structure, ADS(Advanced Design System) circuit simulation results are compared with the measurement results using Network Analyzer, and relatively good agreements are obtained between measurements and simulations.

A Design of SINR Measurement Unit for IEEE 802.16m (IEEE 802.16m 시스템의 SINR 측정기의 설계)

  • Kim, Jun-Woo;Park, Youn-Ok;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12A
    • /
    • pp.1097-1104
    • /
    • 2010
  • This paper presents the signal-to-noise ratio (SNR) and signal-to-interference plus noise ratio (SINR) estimation based on A-Preamble of IEEE 802.16m IMT-Advanced WiMax system with simulation results. The downlink signal of IEEE 802.16m has two kinds of A-Preambles: the PA-Preamble and the SA-Preamble. This paper proposes the effective method of estimating SNR and SINR with A-Preambles, and also shows that this method can recognize the ICI(Inter-Carrier-Interference) occurrence due to doppler frequency. With the recognition of ICI, the mobile station can save the power by operating 1-tap equalizer in usual cases, and activating ICI mitigation module only when it perceives the ICI occurrence.

Enhancement of signal-to-noise ratio for uroflowmetric test regardless of urination situation (요속검사시 배뇨상황에 무관한 신호대잡음비 개선 기법)

  • Kim, Kyung-Ah;Choi, Seong-Su;Lee, Sang-Bong;Kim, Kyoung-Oak;Park, Kyung-Soon;Shin, Eun-Young;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.423-431
    • /
    • 2009
  • Standard uroflowmetry measures the urine weight using single load cell to evaluate the urinary flow rate. Impact noise should be introduced due to gravity when the urine stream falls down into the container upon the load cell. The present study placed three load cells on the three vertices of a regular triangle and the three signals were ensemble averaged to enhance the signal-to-noise ratio(SNR) regardless of how the urination was made. Simulated urination experiment was performed with three different urine collection methods. In all three methods, SNR of the averaged signal was much higher than each load cell signals. With no urine collection device, the present signal averaging technique resulted in SNR values higher by 10~15 dB than when dual funnels or upper funnel were used to guide the urine stream. Therefore, it was demonstrated that the three point measurement followed by with ensemble averaging could enable accurate uroflowmetric test without any specially made urine collection devices.

Construction and Operation of a 37-channel Hemispherical Magnetoencephalogram System (37채널 반구형 뇌자도 측정장치 제작 및 동작)

  • 이용호;김진목;권혁찬;김기웅;박용기;강찬석;이순걸
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.159-165
    • /
    • 2003
  • We developed a 37-channel magnetoencephalogram (MEG) measurement system based on low-noise superconducting quantum interference device (SQUID) magnetometets, and operated the system to measure MEG signals. By using double relaxation oscillation SQUIDs with high flux-4o-voltage transfers, the SQUID outputs could be measured directly by room temperature preamplifiers and compact readout circuits were used for SQUID operation. The average field noise level of the magnetometers is about 3 fT/√Hz in the white region, low enough for MEG measurements when operated inside a magnetically shielded room. The 37 magnetometers were distributed on a hemispherical surface haying a radius of 125 mm. In addition to the 37 sensing channels. 11 reference channels were installed to pickup external noise and to form software gradiometers. A low-noise liquid helium dewar was fabricated with a liquid capacity of 30 L and boil-off rate of 4 L/d. The signal processing software consists of digital filtering, software gradiometer, isofield mapping and source localization. By using the developed system, we measured auditory-evoked fields and localized the current dipoles, demonstrating the effectiveness of the system.

A 0.13-㎛ Zero-IF CMOS RF Receiver for LTE-Advanced Systems

  • Seo, Youngho;Lai, Thanhson;Kim, Changwan
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.61-67
    • /
    • 2014
  • This paper presents a zero-IF CMOS RF receiver, which supports three channel bandwidths of 5/10/40MHz for LTE-Advanced systems. The receiver operates at IMT-band of 2,500 to 2,690MHz. The simulated noise figure of the overall receiver is 1.6 dB at 7MHz (7.5 dB at 7.5 kHz). The receiver is composed of two parts: an RF front-end and a baseband circuit. In the RF front-end, a RF input signal is amplified by a low noise amplifier and $G_m$ with configurable gain steps (41/35/29/23 dB) with optimized noise and linearity performances for a wide dynamic range. The proposed baseband circuit provides a -1 dB cutoff frequency of up to 40MHz using a proposed wideband OP-amp, which has a phase margin of $77^{\circ}$ and an unit-gain bandwidth of 2.04 GHz. The proposed zero-IF CMOS RF receiver has been implemented in $0.13-{\mu}m$ CMOS technology and consumes 116 (for high gain mode)/106 (for low gain mode) mA from a 1.2 V supply voltage. The measurement of a fabricated chip for a 10-MHz 3G LTE input signal with 16-QAM shows more than 8.3 dB of minimum signal-to-noise ratio, while receiving the input channel power from -88 to -12 dBm.