• Title/Summary/Keyword: mean values

Search Result 6,221, Processing Time 0.027 seconds

Studies of Thyroid Function Test Using Radioiodine by Intradermal Injection (방사성(放射性) 옥소(沃素) 피내(皮內) 주사(注射)에 의(依)한 갑상선(甲狀腺) 기능검사(機能檢査)에 관(關)한 연구(硏究))

  • Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.6 no.1
    • /
    • pp.41-49
    • /
    • 1972
  • The author observed the thyroid $^{131}I$ uptake rate using an intradermal injection method. The amount of activity remaining at the site of intradermal injection of 0.1 ml. of $5{\mu}Ci.\;of\;^{131}I$ in physiologic saline was measured in 79 cases of hyperthyroidism and in 24 cases of hypothyroidism. The cases had been confirmed by clinical and laboratory findings, at the department of medicine, (radioisotope clinic) Pusan National University Hospital. Twenty-nine normal control cases were examined currently by the same technique during the period from Jan. 1967 to June 1970. The following results were obtained: 1. In the normal group, the ranges and mean values of the thyroid uptake 10, 15, 20, 25, 30 and 60 minutes after intradermal $^{131}I$ injection, were $0{\sim}10%(6.33{\pm}1.63),\;0{\sim}15%(7.83{\pm}2.12),\;0{\sim}15%(8.46{\pm}2.82),\;5.1{\sim}20%(9.66{\pm}2.27),\;5.1{\sim}25%(10.47{\pm}2.52),\;5.1{\sim}30%(13.03{\pm}4.42)$. 2. In the hyperthyroid group, the ranges and mean values of the thyroid uptake 10, 15, 20, 25, 30 and 60 minutes after intradermal $^{131}I$ injection were $5.1{\sim}45%(22.25{\pm}7.04),\;10.1{\sim}50%(28.32{\pm}6.67),\;15.1{\sim}55%(34.78{\pm}11.63),\;15.1{\sim}65%(37.95{\pm}7.72),\;20.1{\sim}65%(41.49{\pm}0.05)\;and\;20.18096(48.71{\pm}12.51)$. 3. In the hypothyroid group, he ranges of thyroid $^{131}I$ uptake by intradermal $^{131}I$ injection at 10, 15, 20, 25, 30 and 60 minutes lay between 0 and 10%, and the the mean values were $4.23{\pm}1.76,\;5.08{\pm}1.68,\;5.56{\pm}1.70,\;6.02{\pm}1.75,\;6.37{\pm}1.91\;and\;6.95{\pm}2.07$. 4. In conclusion, thyroid function test using an intradermal injection method in cases of hyperthyroidism, showed characteristic values which seemed to be of diagnostic significance.

  • PDF

Characteristic Values of Design Parameters for Geotechnical Reliability Design (지반신뢰성 설계를 위한 설계변수의 특성치 연구)

  • Yoon, Gil-Lim;Yoon, Yeo-Won;Kim, Hong-Yeon
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.5
    • /
    • pp.27-35
    • /
    • 2008
  • Geotechnical characteristic values for reliability-based design were analyzed using domestic marine clays. Analysis results indicate that there were close to mean values in oder of Student/Ovesen, Schneider and EN 1990's approach. However, it was found that the EN 1990's approach is inappropriate far estimating geotechnical characteristic value due to low reliability of estimation results. Four approaches had a trend of evaluating characteristic value conservatively with increasing of soil variability. Also, stability and settlement of breakwater subjected to nominal stress with unimproved soft grounds were computed to investigate the effects of estimated characteristic values. In case of using the Schneider's approach, the ratio of allowable bearing capacity/acting loads suggested 65% of that obtained from using the arithmetic mean approach, and showed underestimated value of 13.6% of the settlement obtained from the latter. The comparison of case designs using a representative value from arithmetic mean approach with the proposed approaches, using characteristic value showed that the former was mostly overestimated.

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.

Behavior Characteristics of Swirl-Twin Spray with Changing Swirl Angle (선회각도변화에 따른 2유체 선회분무의 거동특성)

  • Kang, Wan-Bong;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.943-948
    • /
    • 2000
  • The Twin-fluid Swirl Nozzles are used in many parts of the industry to produce homogeneous spray. This study is to investigate the effects of outer air swiller and inner water swiller on atomization of liquid.. The experiment was carried out with increasing air-flow rate at constant liquid-flow rate and with changing outer air swiller angle and inner water swiller angle. A Particle Dynamics Analyzer(PDA) was used to measure drop size, mean and ms values of axial velocity, number density and Sauter mean diameter(SMD). The axial mean velocity and SMD of droplets were measured along the center line and radial directions. It was found that the higher air flow-rate resulted in the smaller Sauter mean diameter of liquid spray and the higher axial mean velocity of droplets. This experimental results will be conveniently used for the preliminary design stage of twin-fluid nozzle development.

  • PDF

Analysis of mean waiting times for a multiclass cyclic production system (다품목 순환 생산시스템에 대한 평균 대기시간의 분석)

  • Hong, Sung-Jo;Kim, Sang-Jik
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.4
    • /
    • pp.639-647
    • /
    • 1998
  • We consider a multiclass production system processed by a single machine with cyclic order. Each part belongs to one of several classes and arrives at each queue in a Poisson process. The processing discipline at each queue is either exhaustive or gated. We introduce a new approach to analysis of mean waiting times for each queue. We formulate mean waiting times as cost functions on state of the system. The mean waiting times are obtained by solving a set of O($J^2$) linear equations, where J is the number of queues in the system. We also obtain the mean number of parts of each queue in the system at an arbitrary time. Based on this result, we plot the numerical values of the mean waiting times for several parameter settings.

  • PDF

University Student Characteristics of Type of Job Values and Key Competency

  • Bok, Mi-Jung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.5
    • /
    • pp.47-53
    • /
    • 2018
  • This study is aimed to determine types of job values which is searched by 242 university student in Gwangju, to study characteristics of each type, and to analyze key competency of each type. The data were analyed with PASW 18.0 using frequency analysis, k-mean cluster analysis, crosstabs and one-way ANOVA. According to findings, first of all, university student types of job values are divided into 4 groups; a type of intrinsic job values(27.7%), a type of active job value(32.2%), a type of external job value(12.4%), a type of passive job value(27.7%). Secondly, the type of job values showed statistically significant difference only in the monthly allowance of socio-economic variables. Thirdly, the type of job values showed statistically significant difference 'communication', 'mathematics', 'problem solving', 'self development', 'resource management', 'interpersonal skills', 'technical ability', 'understanding organizations' and 'work ethics'.

Effect of a Intentional Scapular Abduction on the Sit-and-Reach Test (의도적인 견갑골 외전이 Sit-and-Reach Test에 미치는 영향)

  • Kim, Suhn-Yeop;Chi, Chang-Yean;Kim, Kwang-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2000
  • Purpose : This study was done to examine the actual effect of the scapular position in these flexibility tests. The purpose of this study was to examine the differences between the measurement of SRT(Sit-and-Reach Test) without intentional abduction of the scapular (pre-test) and with intentional abduction of the scapular (post-test). The hypothesis is: 1. There is no differences in the SRT result of the pre-test and the post-test. 2. There is no differences in the HJA(Hip Joint Angle) result of the pre-test and the post-test. 3. There is no differences in the Spine Motion Test(SMT) result of the pre-test and the post-test. Method : The total 60 people (30 men, 30 women) were participated in this study. In the pre-test, the subjects were asked to sit on the examination table and try the SRT motion; and then the HJA, SRT and the SMT numerical values were taken. In the post-test. the subjects were instructed to intentionally bring the scapula outward from the midline; and the HJA, SRT and the SMT numerical values were taken. Result : In the pre-test. the SRT result averaged 34.17cm. and in the post-test. the SRT result averaged 36.68cm. The difference was about 2.81cm which showed a significant mean statistically (p<0.01). The measurement increased by 8.22%. The HJA was $85.9^{\circ}$ in pre-test, and it was $85.5^{\circ}$ in post-test. giving the $0.4^{\circ}$ differences. Therefore, it didn't have a statistical mean (p>0.05). The SMT value was 69.56cm in the pre-test. and it was 69.28cm in the post-test, about 0.28cm decreased. Therefore, it didn't have a statistical mean (p>0.05). SRT values and HJA values were correlated (p<0.01). SMT values and SRT values (p<0.01), and SMT values and HJA values(p<0.05) were each in counter correlation. Conclusion : The result of the SRT without intentional scapular abduction (34.17cm) and with intentional scapular abduction (36.68cm) showed a significant increase about 8.22% (p<0.01). In SRT, the effect of the intentional scapular abduction on SMT showed no significant means, the pretest value being 69.56cm and the post-test value being 69.28cm (p>0.05).

  • PDF

Serial values for hematologic and biochemical analysis after myocardial infarction in rats

  • Lee, Mi-Jin;Tae, Hyun-Jin;Li, Ying-Hua;Yu, Do-Hyeon;Han, In-Ae;Lee, Seok-Won;Ahn, Dong-Choon;Kim, In-Shik;Park, Jin-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.2
    • /
    • pp.175-186
    • /
    • 2008
  • To diagnose acute myocardial infarction (MI), many cardiac markers have been used in hematologic and biochemical analysis, and many studies have been published for hematologic and biochemical analysis associated with human acute MI. However, after occurrence of acute MI, the serial investigation for values in hematologic and biochemical analysis including chronic MI has rarely been performed. To observe the change of the serial values in hematologic and biochemical analysis, we induced artificial MI. The left main descending artery (LMDA) of the left coronary artery was ligated during the progression (day 1, 3, 5, 7, 14 and 30) of MI. Total 66 Sprague-Dawley rats were divided into the sham group (n=24, thoracotomy without LMDA ligation) and the experimental (MI) group (n=42, with LMDA ligation). And all individual in each group was sacrified at day 1, 3, 5, 7, 14 and 30 for the hematologic and biochemical analysis. In comparison of hematologic analysis between the sham and MI groups, the mean values of red blood cell (RBCs), hemoglobin and hematocrit (HCT) showed a steady increase. In biochemical analysis, the mean values of glucose, cholesterol, total creatine kinase (CK) and isoenzyme MB, and lactate dehydrogenase (LDH) were increased in all MI groups compared with the sham groups. The results of this study suggest that early hematologic and biochemical mean values occurred after acute MI are similar to those of human acute MI. In conclusion, we could observe the alterations and serial values in hematologic and biochemical analysis to the extent of chronic status after acute MI.

Effect of Informativeness on the Anxiety of Hospitalized Patients (정보제공이 입원환자 불안해소에 미치는 효과)

  • 박정옥
    • Journal of Korean Academy of Nursing
    • /
    • v.5 no.2
    • /
    • pp.1-10
    • /
    • 1975
  • Every patient, who enters the hospital has a potential for becoming anxious. The control of hospitalization anxiety experienced by hospital patients is considered to be an important factor in the process of recovery from illness. This study was conducted to investigate the relationship between informativeness and hospitalization anxiety in order to give basic data for psycho-social aspect of nursing care for hospitalized patients. One hundred patients admitted to Kyungpook National University Hospital during the period of Jan. to June 1975 were sampled and divided into two groups; fifty of experimental and fifty of control group. The set of informations prepared by the investigator were given additionally to experimental group while the control group only received routine informations. Both groups were rated according to the Hospitalization Informativeness Scale which consisted of 24 questionaries and 4 categories and Hospitalization Anxiety Scale one or two days prior to discharge from the hospital. The results of the study were as follows; 1 . Mean values of Hospitalization Informativeness Scale revealed significant differences at 0.01 level with experimental group showing higher mean value. Age, sex ana educational states aid not influence the mean values of Hospitalization Informativeness Scale in both groups. 2 . The length of hospitalization did not influence significantly on the mean value of Hospitalization Informativeness Scale in both groups. 3. Rank difference correlation coefficiently between mean value of Hospitalization Informativeness Scale and the importance of information the patient's perceived were revealed significant at 0.01 level in all 4 categories such as admission discharge, treatment and nursing activities, diagnostic test, diagnosis and prognosis, health teaching for the patient and family in experimental group. While, only two categories such as treatment and nursing activities and health teaching for the patient and family in control group were revealed significant correlation. 4. Mean value of Hospitalization Anxiety Scale revealed significant difference at 0.05 level with the experimental group showing lower Hospitalization Anxiety Scale. 5. Correlation coefficiently between Hospitalization Informativeness Scale and Hospitalization Anxiety Scale were revealed significant at 0.01 level in experimental group but there was no significant correlation in control group.

  • PDF

Target Strength Measurements of Live Golden Cuttlefish Sepia esculenta at 70 and 120 kHz

  • Lee, Dae-Jae;Demer, David A.
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.3
    • /
    • pp.361-367
    • /
    • 2014
  • Cuttlefish Sepia esculenta are commercially important in Korea. Assessments of their biomass currently depend on fishery-landings data, which may be biased. Towards fishery-independent acoustic surveys of cuttlefish, target strength (TS) measurements at 70 and 120 kHz were made of 23 live cuttlefish, in early May 2010. The fish were caught by traps in the inshore waters around Geojedo, Korea. The TS were measured using split-beam echosounders (Simrad ES60 and EY500, respectively). The cuttlefish mantle lengths (L) ranged from 15.6 to 23.5 cm (mean L=17.8 cm) and their masses (W) ranged from 335 to 1020 g (mean W=556.1 g). Their mean TS values at 70 and 120 kHz were -33.01 dB (std=1.39 dB) and -31.76 dB (std=2.15 dB), respectively. The mean TS at 70 kHz was 0.17 dB higher than the TS-length relationship resulting from a least-squares fit to the data ($TS=24.67{\log}_{10}L(cm)-64.03$, $r^2$ = 0.52, N=23). The mean TS at 120 kHz was 0.45 dB higher than the fitted TS-length relationship ($TS=40.59{\log}_{10}L(cm)-82.96$, $r^2$ = 0.58, N=23). The differences between the mean TS values and an equation regressed from all of the TS measurements at both frequencies ($TS=24.92{\log}_{10}L(cm)-4.92{\log}_{10}{\lambda}(m)-22.82$, $r^2$ = 0.86, N=46) was 0.22 dB at 70 kHz and 0.31 dB at 120 kHz, respectively.