• Title/Summary/Keyword: maximum shear strength

Search Result 610, Processing Time 0.023 seconds

A Case Study on Local Erosion Characteristics Evaluation of the Inchon Coast (인천 해안지역 지반의 국지적 침식특성 평가)

  • Kwak, Ki-Seok;Lee, Ju-Hyung;Park, Jae-Hyeon;Chung, Moon-Kyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.455-465
    • /
    • 2006
  • In this study, the effect of scour was evaluated by regional and geotechnical characteristics and back data were accumulate for the design against scour through the local erosion characteristics evaluation of the Inchon coast. The erosion characteristics for the undisturbed soil samples collected near the main locations at the Incheon 2nd bridge, the Hwangyeong bridge, and a coast road in Songdo, are determined quantitatively through the scour rate tests. On the basic soil properties test, the bed around the Inchon coast chiefly consists of fined grained soils, and the soil samples were classified as silty clay(ML) or clay(CL) under the Unified Soil Classification System. On the scour rate test, the critical shear stress increases when the undrained shear strength increases as of the general trend of fine grained soils, and the average scour rate for the maximum velocity by 100 year flood is 173mm/hr at the Incheon 2nd bridge, 67mm/hr at the Hwangyeong bridge and 10mm/hr at a coast road in Songdo, respectively. Comparing to the scour rate of coarse grained soil, that of the bed around the Inchon coast is turned out to be very low. Therefore, the relative ability of the bed around the Inchon coast to resist erosion is assumed to be very high.

  • PDF

Analysis of Response Change of Structure due to Tunnel Excavation Conditions in Sand Ground (모래지반에서 터널 굴착조건들을 반영한 상부 블록구조물의 거동변화 분석)

  • Son, Moorak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1541-1549
    • /
    • 2013
  • This study investigates the response of structures to tunnelling-induced ground movements in sand ground, varying tunnel excavation condition (tunnel depth and diameter), tunnel construction condition (ground loss), ground condition (loose sand and dense sand). Four-story block-bearing structures have been used because the structueres can easily be characterized of the extent of dmages with crack size and distribution. Numerical parametric studies have been used to investigae of the response of structures to varying tunnelling conditions. Numerical analysis has been conducted using Discrete Element Method (DEM) to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The results of structure responses from various parametric studies have been integrated to consider tunnel excavation condition, tunnel construction condition, and ground condition and provided as a relationship chart. Using the chart, the response of structures to tunnelling can easily be evaluated in practice in sand ground.

Response Analysis of Frame Structures with the Consideration of Tunnel Construction (프레임구조물의 터널시공에 따른 거동분석)

  • Son, Moorak;Park, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.121-127
    • /
    • 2012
  • This paper investigates the response of frame structures with the consideration of tunnel construction (ground loss) conditions. The response of four-story open frame structure and block-infilled frame structures, which are subjected to tunnelling-induced ground movements, has been investigated in different construction (ground loss) conditions using numerical analysis. The open frame structure has been modelled as an elastic structure, while the block-infilled frame structure has been modelled to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of the two different frame structures has been investigated in terms of construction (ground loss) conditions considering the magnitude of deformations and cracks in structures. In addition, the damage levels, which are possibly induced in the structures, has been provided in terms of construction (ground loss) conditions using the state of strain damage estimation criterion (Son and Cording, 2005). The results of this study will provide a background for better understandings for controlling and minimizing building damage on nearby frame structures due to tunnelling-induced ground movements.

Dynamic response of a laminated hybrid composite cantilever beam with multiple cracks & moving mass

  • Saritprava Sahoo;Sarada Prasad Parida;Pankaj Charan Jena
    • Structural Engineering and Mechanics
    • /
    • v.87 no.6
    • /
    • pp.529-540
    • /
    • 2023
  • A novel laminated-hybrid-composite-beam (LHCB) of glass-epoxy infused with flyash and graphene is constructed for this study. The conventional mixture-rule and constitutive-relationship are modified to incorporate filler and lamina orientation. Eringen's non-local-theory is used to include the filler effect. Hamilton's principle based on fifth-order-layer-wise-shear-deformation-theory is applied to formulate the equation of motion. The analogous shear-spring-models for LHCB with multiple-cracks are employed in finite-element-analysis (FEA). Modal-experimentations are conducted (B&K-analyser) and the findings are compared with theoretical and FEA results. In terms of dimensionless relative-natural-frequencies (RNF), the dynamic-response in cantilevered support is investigated for various relative-crack-severities (RCSs) and relative-crack-positions (RCPs). The increase of RCS increases local-flexibility in LHCB thus reductions in RNFs are observed. RCP is found to play an important role, cracks present near the end-support cause an abrupt drop in RNFs. Further, multiple cracks are observed to enhance the nonlinearity of LHCB strength. Introduction of the first to third crack in an intact LHCB results drop of RNFs by 8%, 10%, and 11.5% correspondingly. Also, it is demonstrated that the RNF varies because of the lamina-orientation, and filler addition. For 0° lamina-orientation the RNF is maximum. Similarly, it is studied that the addition of graphene reduces weight and increases the stiffness of LHCB in contrast to the addition of flyash. Additionally, the response of LHCB to moving mass is accessed by appropriately modifying the numerical programs, and it is noted that the successive introduction of the first to ninth crack results in an approximately 40% to 120% increase in the dynamic-amplitude-ratio.

Development of a Sampler that Minimizes Sample Disturbance and Review of its Applicability (인발시 시료이탈을 최소화한 불교란시료 채취 샘플러 개발 및 적용성 검토)

  • Kim, Jongkwan;Han, Jin-Tae;Park, Ka-hyun;Shin, Hyu-Soung;Zhuang, Li;Yeom, Sun;Kim, Ki-Seog
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.3
    • /
    • pp.17-27
    • /
    • 2023
  • In order to accurately determine soil characteristics, it is necessary to collect undisturbed samples, and it is important to collect these samples with minimal disturbance. In this study, a sampler that minimizes sample disturbance was developed by attaching a catcher to the tip, and its applicability was reviewed through in situ sampling, X-ray CT, and laboratory tests. Results confirmed that horizontal cracks are likely to occur when using the Shelby tube sampler, whereas these cracks can be suppressed when using the newly developed sampler. Moreover, consolidation and shear test results showed that the samples collected using the newly developed sampler showed higher maximum shear strength compared to those collected using the Shelby tube sampler.

Response Analysis of Nearby Structures to Excavation-Induced Advancing Ground Movements (지반굴착 유발 진행성 지반변위에 의한 인접구조물의 거동분석)

  • Son, Moorak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4C
    • /
    • pp.153-162
    • /
    • 2009
  • This paper investigates the effects of excavation-induced ground movements on nearby structures, considering soil-structure interactions of different soil and structural characteristics. The response of four and two-story block structures, which are subjected to excavation-induced advancing ground movements, are investigated in different soil conditions using numerical analysis. The structures for numerical analysis are modelled to have cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of four and two-story block structures are investigated with advancing ground movement phases and compared with the response of structures which are subjected to excavation-induced total ground movement. The response of structures is compared among others in terms of the magnitude and shape of deformations and cracks in structures for different structure and ground conditions. The results of the comparison provide a background for better understandings for controlling and minimizing building damage on nearby structures due to excavation-induced ground movements.

AN EXPERIMENTAL STUDY ON THE FATIGUE CHARACTERISTICS OF ORTHODONTIC BRACKETS BONDED TO ENAMEL (교정용 브라켓 접착부의 피로특성에 관한 실험적 연구)

  • Choi, Hae-Woon;Kim, Jeong-Gee
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.55-72
    • /
    • 1995
  • The purpose of this study is to evaluate the effects of mechanical and thermal fatigue on the shear bond strength(SBS) in orthodontic brackets bonded to human premolars with chemically cured adhesive(Mono-$Lok^2$, Rocky Mountain Orthodontics). Two types of metal brackets (Ormesh, Microloc) and three types of ceramic brackets (Fascination, Starfire, Transcend 2000) were used in this study. The $10^6$ loadcycles of $|7.4{\times}10{^2}sin2{\pi}ft|g{\cdot}cm$ and the 1,000 thermocycles of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ baths were acturated as mechanical and thermal fatigue stress, and SBS were measured after each fatigue test. The fracture sites were examined by stereoscope and scanning electron microscope. The results obtained were summarized as follows, 1. In static shear bond test, Fascination brackets showed the maximum SBS($20.78\pm3.45$ MPa) and Microloc brackets showed the minimum SBS($14.88\pm3.10$ MPa). Fascination and Starfire brackets showed significantly greater SBS than Microloc brackets(P<0.05). 2. In mechanical fatigue test, Fascination brackets showed the maximum SBS ($20.19\pm3.45$ MPa) and Starfire brackets showed the minimum SBS($9.10\pm8.33$ MPa). The SBS or Transcend 2000 brackets(P<0.01) and Starfire brackets(P<0.05) significantly decreased after $10^6$ loadcycles. 3. In thermocycling test, Ormesh brackets showed the maximum SBS ($19.36\pm2.76$ MPa) and Starfire brackets showed the minimum SBS($11.94\pm6.86$ MPa). The SBS of Transcend 2000(P<0.01), Microloc and Starfire brackets(P<0.05) significantly decreased after $10^3$ thermocycles. 4. Failure sites of thermocycling groups were similar to those of static groups but after mechanical fatigue test, Ormesh and Transcend 2000 brackets failed at the bracket/resin interface and Microloc brackets failed within adhesive. Facination brackets failed at the enamel/resin interface irrespective of experimental condition.

  • PDF

A Study on Structural Performance Evaluation of RC Beams Strengthened with CFRP Plate (탄소섬유판으로 보강된 철근콘크리트 보의 보강성능에 관한 연구)

  • Kim Joong-Koo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.6 s.22
    • /
    • pp.212-217
    • /
    • 2004
  • Carbon fiber reinforced plastic(CFRP) plate Is one of the alterative materials for soengthening of reinforced and prestressed connote members due to excellent strength and light weight In this paper, the behavior of beams strengthened with CFRP plate and CFS(Carbon fiber sheet) is observed and analyzed from the test results. Especially specimens with thick plate is tested when large moment and large shear lone appear in same position. The main failure mode is a peeling-off of the CFRP plate near the loading points due to flexural-shear crack, Because of this failure mode, failure load is not linearly proportional to the thickness of CFRP plates. When beam is wrapped with CFS around oかy loading point it does not influence on the failure loads. Depending on the loading pattern, it is necessary to consider different design criteria for reinforced concrete members with external reinforcement. When line moment and large shear force appear in same location, maximum thickness may limit to 0.6mm and ratio between moment of strengthened beam and moment of unstrengthened beam is proposed 1.5-2.0. In order to use the plate of thicker than 6mm, CFS may be extended to the location which moment of strengthened beam is 1.5 times than moment of unstrengthened beam.

An Experimental Study on Seismic Performance of Two-story Reinforced Concrete Frames Retrofitted with Internal Steel Frame and Wall Type Friction Damper (내부 철골끼움골조 및 벽체형 마찰댐퍼(WFD)로 보강된 2층 철근콘크리트골조 내진성능에 대한 실험적 연구)

  • Yoo, Chang-Gi;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.64-72
    • /
    • 2022
  • In this study, in order to confirm the seismic performance of reinforced concrete frames retrofitted with Wall Friction Damper(WFD), the test was conducted by setting two-story Reinforced concrete frames (reference specimen, OMF-N and specimen retrofitted with internal H-shaped steel frame and WFD, OMF-ALL(H)) as main variables. The WFD Seismic Retrofit Method is a mixture of strength improvement and energy dissipation methods. To prevent the pre-destruction of existing structure by friction force before sufficient energy dissipation of WFD, the internal H-shaped steel frame and chemical anchor that penetrates the side of the beam were used to install WFD. According to the test results, the OMF-N specimen showed an brittle failure pattern caused by the shear force of the R/C column after the maximum strength was expressed. The OMF-ALL(H) specimen showed that the reduction of pinching effect and the failure of the RC column occurred. Also, the maximum strength, cumulative energy dissipation and ductility of OMF-ALL(H) increased 3.01 times, 7.2 times and 1.72 times for OMF-N. As a results, test results revealed that the WFD Seismic Retrofit Method installed on Reinforced concrete structure improves the seismic performance and the strengthening effect is valid.

Evaluation of Flexural Performance of Eco-Friendly Alkali-Activated Slag Fiber Reinforced Concrete Beams Using Sodium Activator (나트륨계 알칼리 활성화제를 사용한 친환경 알카리활성 슬래그 섬유보강콘크리트 보의 휨성능 평가)

  • Ha, Gee-Joo;Yi, Dong-Ryul;Ha, Jae-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.170-178
    • /
    • 2015
  • In this study, it was developed eco-friendly alkali-activated slag fiber reinforced concrete using ground granulated blast furnace slag, alkali activator (water glass, sodium hydroxides), and steel fiber. Eight reinforced concrete beam using alkali-activated slag concrete were constructed and tested under monotonic loading. The major variables were mixture ratio of alkali activator, mixed/without of steel fiber. Experimental programs were carried out to improve and evaluate the flexural performance of such test specimens, such as the load-displacement, the failure mode, the maximum load carrying capacity, and ductility capacity. All the specimens were modeled in scale-down size. The reinforced concrete beams using the eco-friendly alkali-activated slag fiber reinforced concrete was failed by the flexure or flexure-shear in general. In addition, the maximum strength increased with the adding the mol of sodium hydroxide, and the specimen reinforced the steel fiber showed the value of maximum strength which is increased by 15.8% through 25.9%. It is thought that eco-friendly alkali-activated slag fiber reinforced concrete can be used with construction material and product to replace normal concrete. If there is applied to structures such as precast concrete member and production of 2nd concrete product, it could be improved the productivity and reduction of construction duration etc.