DOI QR코드

DOI QR Code

An Experimental Study on Seismic Performance of Two-story Reinforced Concrete Frames Retrofitted with Internal Steel Frame and Wall Type Friction Damper

내부 철골끼움골조 및 벽체형 마찰댐퍼(WFD)로 보강된 2층 철근콘크리트골조 내진성능에 대한 실험적 연구

  • 유창기 (한양대학교 건축공학과) ;
  • 최창식 (한양대학교 건축공학과)
  • Received : 2022.09.28
  • Accepted : 2022.11.07
  • Published : 2022.12.31

Abstract

In this study, in order to confirm the seismic performance of reinforced concrete frames retrofitted with Wall Friction Damper(WFD), the test was conducted by setting two-story Reinforced concrete frames (reference specimen, OMF-N and specimen retrofitted with internal H-shaped steel frame and WFD, OMF-ALL(H)) as main variables. The WFD Seismic Retrofit Method is a mixture of strength improvement and energy dissipation methods. To prevent the pre-destruction of existing structure by friction force before sufficient energy dissipation of WFD, the internal H-shaped steel frame and chemical anchor that penetrates the side of the beam were used to install WFD. According to the test results, the OMF-N specimen showed an brittle failure pattern caused by the shear force of the R/C column after the maximum strength was expressed. The OMF-ALL(H) specimen showed that the reduction of pinching effect and the failure of the RC column occurred. Also, the maximum strength, cumulative energy dissipation and ductility of OMF-ALL(H) increased 3.01 times, 7.2 times and 1.72 times for OMF-N. As a results, test results revealed that the WFD Seismic Retrofit Method installed on Reinforced concrete structure improves the seismic performance and the strengthening effect is valid.

본 연구에서는 WFD(Wall Friction Damper)를 보강한 철근콘크리트 골조의 내진성능을 확인하기 위해 2층 철근콘크리트 골조 의 보강방법(무보강, 내부 H- 형철골과 WFD보강)을 주요 변수로 하였다. WFD 내진 보강 공법은 강도 향상과 에너지 소산 공법을 혼합한 것이다. WFD의 충분한 에너지 소산 이전에 보강재와 기존 구조물의 접합부에서 사전 파괴를 방지하기 위해 내부 H형 철골과 보 측면을 관통하는 케미컬 앵커를 사용하여 WFD를 설치하였다. 시험결과 OMF-N 시험체는 최대강도 발현 후 R/C 기둥의 전단력에 의한 취성파괴 양상을 보였다. OMF-ALL(H) 실험체는 핀칭 효과의 감소와 RC 기둥의 파손이 발생함을 보였다. 또한 OMF-ALL(H)의 최대 강도, 누적 에너지 소산 및 연성은 OMF-N의 경우 3.01배, 7.2배 및 1.72배 증가하였다. 그 결과 철근콘크리트 구조물에 시공한 WFD 내진 보강공법이 내진성능을 향상시키고 보강효과가 유효한 것으로 나타났다.

Keywords

Acknowledgement

이 연구는 2021년도 정부(과학기술정보통신부) 연구비 지원에 의한 결과의 일부임(과제번호: NRF-2020R1A4A1019074).

References

  1. Lee, K., Wi, J., Kim, Y., and Lee, H. (2009), Seismic safety evaluation of Korean R/C school buildings built in the 1980s, Journal of the Korea Institute for Structural Maintenance Inspection, 13(5), 149-159.
  2. Kaltakci, M., and Ozturk, O. (2012), An experimental study on the strengthening of non-ductile reinforced concrete frames via external shear wall, European Journal of Environmental and Civil Engineering, 16(1), 59-76. https://doi.org/10.1080/19648189.2012.667672
  3. Kim, M., Choi, H., Song, S., and Lee, Y. (2013), Seismic capacity of reinforced concrete frames retrofitted with H-beam frame, Journal of the Earthquake Engineering Society of Korea, 17(3), 127-132. https://doi.org/10.5000/EESK.2013.17.3.127
  4. Park, J. (2010), An experimental study on the seismic performance of RC frames with steel dampers, Land and Housing Institute Journal, 1(1), 43-50.
  5. Jung, H., Jung, J., and Lee., K. (2019), Seismic performance evaluation of internal steel frame connection method for seismic strengthening by cylic load test and nonlinear analysis, Journal of the Korea Concrete Institute, 31(1), 79-88. https://doi.org/10.4334/jkci.2019.31.1.079
  6. Lee, B., Hwang, D., Choi, Y., Kim, Y., and Lee, K. (2019), Seismic capacity evaluation of full-size two-story R/C frame strengthened with HSWF external connection method by pseudo-dynamic test, Journal of the Korea Concrete Institute, 31(1), 89-97. https://doi.org/10.4334/jkci.2019.31.1.089
  7. Lee, C. (2015), Structural performance of SAFE dampers combining shear-type friction damper and non-uniform steel strip damper, Ph.D. Dissertation, Korea University.
  8. Shin, J. (2004), Behaivor of Reinforced Concrete Frame with Steel Plate Slit Damper, Master's Dissertation, Kwangwoon University.
  9. Baek, E., Oh, S., and Lee, S. (2013), Performance of seismic retrofit according to the stiffness and strength ratios of steel damper to reinforced concrete frame, Journal of the Earthquake Engineering Society of Korea, 17(4), 171-180. https://doi.org/10.5000/EESK.2013.17.4.171
  10. Korean Agency for Technology and Standards, 1-14.
  11. Jo, S. (2013). An experimental study on toggle-rotational friction damper for strengthening R/C buildings, Master's Dissertation, Chonnam National University.
  12. Architectural Institute of Korea. (2018), Site Inspection and Damage Investigation of Buildings by Earthquakes in Gyoungju and Pohang, 352.
  13. Park, R. (1988), Ductility evaluation from laboratory and analytical testing, Proceedings of Ninth World Conference on Earthquake Engineering, 8, 605-616
  14. Park, R., and Paulay, T. (1975), Reinforced Concrete Structures, New York, John Wiley & Sons, 769.
  15. Lee, J. (2004). Seismic Capacity and Seismic Retrofitting of Low Rise Buildings, Ph.D. Dissertation, Kwangwoon University.
  16. KS F 2405 (2010). Standard Test Method for Compressive Strength of Concrete, Korean Agency for Technology and Standards, 1-16.
  17. KS B 0801 (2017). Test pieces for tensile test for metallic materials.