• Title/Summary/Keyword: maximum rate phenomenon

Search Result 86, Processing Time 0.031 seconds

A Numerical Analysis on Thermal Stratification Phenomenon by In-Leakage in a Branch Piping

  • Park Jong-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2245-2252
    • /
    • 2005
  • Thermal stratification in the branch piping of power plants can be generated by turbulent penetration or by valve leakage. In this study, a numerical analysis was performed to estimate the thermal stratification phenomenon by in-leakage in the SIS branch piping of nuclear power plant. Leakage rate, leakage area and leakage location were selected as evaluation factors to investigate the thermal stratification effect. As a result of the thermal stratification effect according to leakage rate, the maximum temperature difference between top and bottom of the horizontal piping was evaluated to be about 185K when the valve leakage rate was about 10 times as much as the allowed leakage rate. For leakage rate more than 10 times the allowed leakage rate, the temperature difference was rapidly decreased due to the increased mixing effect. In the result according to leakage area, the magnitude of temperature difference was shown in order of $3\%,\;1\%\;and\;5\%$ leakage area of the total disk area. In the thermal stratification effect, according to the leakage location, temperature difference when leakage occurred in the lower disk was considerably higher than that of when leakage occurred in the upper disk.

A Study on Thermal Stratification Phenomenon due to In-Leakage in the Safety Injection Piping of Nuclear Power Plant (원전 안전주입 배관에서의 In-Leakage 에 의한 열성층 현상에 관한 연구)

  • Kim, K.C.;Park, M.H.;Youm, H.K.;Kim, T.Y.;Lee, S.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1633-1638
    • /
    • 2003
  • In case that in-leakage through the valve disk occurs, a numerical study is performed to estimate on thermal stratification phenomenon in the Safety Injection piping connected with the Reactor Coolant System piping of Nuclear Power Plant. As the leakage flow rate increases, the temperature difference between top and bottom of horizontal piping has the inflection point. In the connection point of valve and piping, the maximum temperature difference between top and bottom was 185K and occurred in the condition of 10 times of standard leakage flow rate. In the connection point of elbow and horizontal piping, the maximum temperature difference was 145K and occurred in the condition of 15 times of standard leakage flow rate. In the vertical piping of Safety Injection piping, the near of connection point between elbow and vertical piping showed the outstanding thermal stratification phenomenon in comparison with another region because of turbulent penetration from Reactor Coolant System piping. In order to prevent damage of piping due to the thermal stratification when in-leakage through the valve disk occurs, the connection points between valve and piping, and the connection points between elbow and piping need to be inspected continually.

  • PDF

A Study on the Variation of the Body surface Area by the Arm movements to Somatotype -The Subject of the College Men- (체형별 상복동작에 따른 상체의 체표면 변화에 관한 연구 -남자대학생을 중심으로-)

  • 김진경
    • Journal of the Korean Home Economics Association
    • /
    • v.26 no.2
    • /
    • pp.1-13
    • /
    • 1988
  • The purpose of this study was to classify somatotype of males, to show changes of the body skin surface by the somatotype. The size of sample was 156 males between age 20 and 24. Somatotype classified into Bending somatotype, Standard somatotype, Turning over somatotype. And according to the somatotype, changing of the upper part of the body by the arm movements analyzed through gypsum experiment. The result obtained from this study were as follows; 1. the variation of the upper part of the body form by changing the am movements, by the increasing of movements, shoulder-point ws moved to be inside or upside, the anterior armpit point & armpit point were moved to the upside. 2. As a result of investigating into the rate of the expansion and contraction of the basic lines and body surface area by the arm movements, the rate of expansion and contraction of the basic lines by the arm movements, the side sea length showed the maximum rate of extension in 135 degrees, the shoulder length showed the maximum rate of contraction in 135 degrees. The rate of expansion and contraction on the body surface area by the arm movements showed the phenomenon of contraction, of items F1, F6, B1, B9 showed the phenomenon of extension, of items F3, F4, F8, F9, B8, B9. 3. According to somatotypes, items which show the significant difference were, of items f3, f8, b3, b8, F2, F7, F8, B3, B7, in all movements.

  • PDF

Work-rate Estimation for Predicting Fretting-wear in SG Tubes due to Turbulence Excitation (난류 가진에 의한 증기발생기 전열관의 마모 일률 평가)

  • 조봉호;유기완;박치용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.115-118
    • /
    • 2004
  • In this study, amplitudes of turbulence excitation are obtained for selected tubes inside the KSNP SG and their normal work-rates are investigated to estimate the magnitude of fretting-wear. From the results of numerical calculation, row 40&41 tubes show the maximum work-rates. Up to this row number, the work-rates inside the row 41 have much larger values than those of outside tubes. This phenomenon reveals the particular central one which has larger normal work-rate than that of outside zone. It turns out that both of the higher local mode at the U-bend region and the larger value of effective mass in the central region Increase the normal work-rate enormously.

  • PDF

An Experimental Study on the Cooling Characteristics of the Liquid Cooling Radiator of the Natural Convection Type by Using the PCM (PCM을 적용한 자연대류형 수냉식 방열기의 냉각특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.324-329
    • /
    • 2008
  • The liquid cooling effect of a natural convection type radiator by using the PCM has been investigated experimentally. The radiator size is $423{\times}295{\times}83$ mm and PCM container size is $398{\times}270{\times}26$ mm. The objective is elapsed time higher than maximum time to reach for maximum operating temperature of a general liquid cooling radiator. This study, in order to study on the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, ambient and melting point of three type PCM. For the above experimental parameter, the melting time was performed about 180/250/560 min at input power 150 W and ambient $30^{\circ}C$ from using the three type PCM(PCM_S1/S2/S3) respectively. Furthermore, the effects of the thermal dissipation was decreased higher input power than lower input power at heating block and melting time of PCM. However, the effects of mass flow rate did not nearly affect of the thermal performance especially.

  • PDF

Study on the Frosting Phenomenon of the Fin and Tube Heat Exchanger with a Louvered Fin (루버형 휜을 가진 휜관형 열교환기의 착상현상 연구)

  • Kim, Jung-Kuk;Kuwahara, Ken;Koyama, Shigeru;Park, Byung-Duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.4
    • /
    • pp.157-163
    • /
    • 2008
  • The present study investigated the pressure drop and the total frost mass of the louvered fin type heat exchanger, which is widely used at the air-conditioning system. The pressure drop due to the frosting phenomenon and the total frost mass were investigated by changing the wet bulb temperature condition of the inlet air. Hence the brain of 55wt% was used as a cooling solution instead of a common refrigerant. The temperature difference between the brine and the tube outside wall at the outlet of heat exchanger was $10^{\circ}C$, at maximum, higher than that at the inlet of heat exchanger. As the wet bulb temperatures were increased, the pressure drop was linearly increased due to the increment of frost mass. And the increment of heat exchange rate was smaller than that of inlet air enthalpy due to the increment of frost mass. The pressure drop of air side was rapidly increased due to the progress of frosting phenomena. The run time that the pressure drop occurred rapidly was decreased by the growth of frost.

  • PDF

Characteristics of Resistant Lines to High-Temperature Injury in Ginseng (Panax ginseng C. A. Meyer)

  • Lee, Joon-Soo;Lee, Jang-Ho;Ahn, In-Ok
    • Journal of Ginseng Research
    • /
    • v.34 no.4
    • /
    • pp.274-281
    • /
    • 2010
  • This experiment was conducted to examine ginseng lines resistant and susceptible to high-temperature injury and to investigate characteristics of the selected lines: leaf burning phenomenon, chlorophyll content, quantum yield, and maximum light interception rate. The leaf burning phenomenon incidence rates of the resistant lines Yunpoong, high-temperature injury resistance (HTIR)1, HTIR2, and HTIR3 were low: 5.8%, 3.6%, 4.0%, and 1.9%, respectively. Resistance of the susceptible lines Chunpoong, high-temperature injury susceptible (HTIS)1, and HTIS2 was high: 58.5%, 23.2%, and 21.7%, respectively. The chlorophyll content (SPAD value) of the resistant lines Yunpoong, HTIR1, HTIR2, and HTIR3, which were exposed to high temperatures and intense light, remained as high at 24.8, 27.9, 24.9, and 30.6, respectively, but that of the susceptible lines Chunpoong, HTIS1, and HTIS2 was low at 21.0, 21.1, and 20.1, respectively. During the summer season, the quantum yield of the resistant lines (Yunpoong, HTIR1, HTIR2, and HTIR3) changed little, but that of the susceptible lines (Chunpoong, HTIS1, and HTIS2) changed dramatically. The maximum light interception rate (Fm/Fv value) for the resistant lines (Yunpoong, HTIR1, HTIR2, and HTIR3) was as high as 0.848, 0.794, 0.805, and 0.813, respectively, while that of the susceptible lines (Chunpoong, HTIS1, and HTIS2) was 0.678, 0.642, and 0.717, respectively. Based on these results, the high-temperature injury-resistant lines seemed to be less susceptible to high light, even at high temperatures. Future studies on red ginseng quality and its active ingredients in resistant ginseng lines and field experimentation will be conducted to verify the potential of the resistant lines.

Study on a Multi-pipe Water Hammer Phenomenon by using CFD of Rapid Valve Closing (전산유체해석(CFD)을 이용한 밸브의 급폐쇄에 따른 다중 배관 수격 현상에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Kang, Moon-Sun;Choi, Jong-Woong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.479-487
    • /
    • 2013
  • This study was to investigate characteristics for the pressure wave propagation and the maximum pressure near a rapid closure valve which was installed the end of multi piping network. The multi piping network consists of one inlet and three outlet with straight pipes. The diameter of the pipes including the valve was 100 mm, 80 mm, 80 mm respectively. The valve was rapidly closed with the instantaneous time which was 0.023s in the level for the water hammer. For the simulation, the influence of the pipe thickness and deformation due to pressure-wave-propagation was not considered. CFD was conducted under the following condition : the initial pressure was 1bar in the inlet and the mass flow rate was 7.83 kg/s in the outlet(the velocity in the pipe with 100 mm diameter was 1 m/s). As the valve have conditions that were status with and without fluid flow in the pipe after valve closing, the maximum pressure change and the frequency analysis were examined. As the results, the case that was status with fluid flow appeared the higher maximum pressure than another's, the maximum frequency band was about 10 ~ 11 Hz.

Operation Characteristics of Bypass Diode for PV Module (태양전지 모듈의 바이패스 다이오드 동작 특성 분석)

  • Kim, Seung-Tae;Park, Chi-Hong;Kang, Gi-Hwan;Lawrence, Waithiru C.K.;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • In this paper, an I-V characteristics of bypass diode has been studied by counting the shading effect in photovoltaic module. The shadow induces hot spot phenomenon in PV module due to the increase of resistance in the current path. Two different types of PV module with and without bypass diode were fabricated to expect maximum output power with an increasing shading rate of 5 % on the solar cell. Temperature distribution is also detected by shading the whole solar cell for the outdoor test. From the result, the bypass diode works properly over 60 % of shading per cell with constant output power. Maximum power generation in case of solar cell being totally shaded with bypass diode decreases 41.3 % compared with the one under STC(Standard Test Condition). On the other hand, the maximum output power of the module without bypass diode gradually decreases by showing hot spot phenomenon with the increase of shading ratio on the cell and finally indicates 95.5 % of power loss compared with the output under STC. Finally the module temperature measured increases around $10^{\circ}C$ higher than that under STC due to hot-spots which come from the condition without bypass diode. It has been therefore one of the main reasons for degrading the PV module and shortening the durability of the PV system.

Observation of Reservoir Current Using Drifter (The Case Study of Yongdam Reservoir) (Drifter를 이용한 저수지 수리거동 조사 (용담댐을 중심으로))

  • Lee, Yo-Sang;Koh, Deok-Koo;Chae, Hyo-Sok;Han, Kyung-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.200-209
    • /
    • 2012
  • The current of the water body is very important information for the water quality management on reservoirs. It is applied to hydraulics and water quality model for simulation. In this regard, the current characteristic of water body is the basic information that can be used to predict various conditions. However, it is very slow flowing and is affected by the reservoir operations and external factors. As such, an accurate measurement of the current is a difficult problem. In order to measure the water current, we constructed a drifter. According to the result of flow survey at Yongdam reservoir, 5m and 10 m depth layer flow was investigated from the upstream to the downstream, during a flood period. Maximum flow rate of 5 m depth is 13.8 cm $sec^{-1}$ and 10 m depth shows 4 cm $sec^{-1}$, respectively. But 2m depth shows a backward flow and maximum flow rate is 4 cm $sec^{-1}$. Density currents flow plays the role of back flow in reservoirs. Flow velocity in the reservoir was measured in the range of 1~2 cm $sec^{-1}$, at normal flow season, and the flow direction were different for each survey. This phenomenon occurs because the reservoir volume is very large, compared to the inflow and outflow volume.