• 제목/요약/키워드: maximum allowable temperature

검색결과 102건 처리시간 0.03초

정렬불량에 따른 틸팅 패드 스러스트 베어링의 운전 성능 한계 검토 (Operating Performance Limitations of Tilting Pad Thrust Bearings Due to Misalignment)

  • 송애희;최성필;김선진
    • Tribology and Lubricants
    • /
    • 제36권2호
    • /
    • pp.82-87
    • /
    • 2020
  • In thrust bearings, the thrust collar and bearing surface need to be parallel to each other to ensure that all pads share the same load. In rotating machines, the shaft system cannot achieve perfect alignment. Misalignment of the thrust collar results in some pads supporting a higher load than others and excessive loads being placed on some pads. Consequently, high loads and high temperatures may occur in the bearing. Thus, in this study, we aim to analytically evaluate the performance of a misaligned non-equalizing direct lubricated tilting pad thrust bearing. We define the oil film thickness of the misaligned thrust bearing using the Byrant angle. Additionally, we calculate the pressure distribution and temperature distribution of the thrust bearing using the generalized Reynolds equation and energy equation. The design limit of the thrust bearing is defined by the load and temperature. Therefore, we evaluate the allowable misalignment angle as the limit of the maximum load and temperature. The analysis results demonstrate that an increase in the speed and load corresponds to a smaller allowable misalignment angle. However, as this is not the same for all thrust bearings, evaluating the allowable misalignment angle at each thrust bearing is essential.

교량 신축부 허용 침목간격 검토 (Review on the Allowable Sleeper Spacing at a Bridge Expansion Joint)

  • 이의재;배상환;이호룡;최진유
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1248-1253
    • /
    • 2011
  • It is increasing construction of long span railway bridge with concrete track system for speed up of railway and efficient maintenance of track. As the sleeper of the concrete track system layed on a bridge is fixed on deck of the bridge, the displacement of the sleeper and deck is same. Therefore, the spacing between two sleeper installed at the end of the adjacent deck near the expansion joint of bridge becomes vary according to the longitudinal expansion of a deck by temperature change. By the way, if the spacing of sleepers become increase excessively, it causes large bending stress of in a rail, and it can leads failure or reduction of fatigue life of the rail. Further more, the excessive displacement of the rail may induce decrease ride comfort as well as corrugation of rail surface. Therefore, it is required to determine the allowable maximum sleeper spacing to prevent such problems. For the purpose, investigation on the influence factor on sleeper spacing for straight track was carried out. Variation of bending moment in a rail, wheel force, and the ratio of primary and secondary deflection of the rail according to sleeper spacing was investigated, and, as a result, the maximum allowable sleeper spacing at the bridge expansion joint was suggested.

  • PDF

디젤차량 연비시험에 있어 시험온도 및 냉각팬 조건이 미치는 영향분석에 관한 연구 (A Study on the Influence of Test Temperature & Cooling Fan Condition on the Fuel Test of Diesel Vehicle)

  • 김현진;김성우;임재혁;노경하;이정천;김기호;오상기
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.46-55
    • /
    • 2017
  • Due to the arise of natural disasters caused by global warming, consumers have more interest in the fuel efficiency of their vehicles, and fuel efficiency became an important factor in comparing vehicles. In this market situation, methods to measure fuel efficiency has become one of the main interests of vehicle related organizations and laboratories, and the current method to measure fuel efficiency is to follow the notification established by the ministry of trade, industry and energy, ministry of environment, and the ministry of land, infrastructure and transport. In this study, we analyze the influence of vehicle fuel efficiency according to test temperature and cooling fan condition which have the possibility to cause difference in fuel efficiency. The analysis results of the influence of the fuel efficiency according to the test temperature, the difference of the fuel efficiency of the test temperature ($21{\sim}29^{\circ}C$) within the allowable range of the notification showed a maximum difference of 2.9%. Therefore, it is necessary to consider the introduction of a test method that permits only the temperature change based on the reference point as the allowable range even in the test within the allowable range. The analysis of the influence of the fuel efficiency according to the cooling method showed no significant effect, and it seems reasonable to maintain the test method of the current notification.

접지선 굵기에 관한 연구 (The study on the ground wire size)

  • 최홍규;최병숙;송영주
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.97-102
    • /
    • 2003
  • Ground in must choose enough sectional area of conductor endurably in maximum fault current, fault duration time, maximum allowable temperature and have strong durability and life-time can bear enough from spontaneous corrosion or electrolytic corrosion and must choose material that problem does not exist electrically and mechanically when connection or junction. In this paper, modeled new ground wire size numerical formula, and examine and compare of modeled numerical formula and abroad regulation, and proved and analyzed validity of the new ground wire size computation method because do simulation to computer program.

  • PDF

항공기 이륙추력 감소법 적용 (Application of Aircraft Reduced Takeoff Thrust Method)

  • 노건수
    • 한국항공운항학회지
    • /
    • 제15권3호
    • /
    • pp.70-76
    • /
    • 2007
  • The benefits for using reduced takeoff thrust are many, ranging from lower maintenance and operating costs to improved engine and dispatch reliabilities. Some pilots, however, are apprehensive about using reduced thrust. They are particularly reluctant to use the maximum permissible level of reduced thrust. Two common arguments are (1)If reduced thrust is used, then the airplane will not be able to clear the obstacles if an engine fails during takeoff, and (2)If the maximum allowable assumed temperature is used, then there will be no stopping margin left if the takeoff is aborted. There is the notion that using reduced thrust sacrifices safety. The intent of this discussion is to: (1)Show that reduced thrust performance meets all regulatory requirements (2)Show that the Assumed Temperature method includes inherent extra performance margins (3)Show how to maximize performance margins while maximizing thrust reduction.

  • PDF

발전소 순환수 및 복수 계통 케이블 건전성 평가 (Cables Condition Assessment for Circulating Water Pump & Condenser Extraction Pump)

  • 하체웅;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.614-615
    • /
    • 2007
  • There are roughly a hundred types of cables in power plants. The distribution of circuits in a nuclear plant is comprised of 20% instrument cables, 61% control cables, 13% AC power cables, 1% DC power cables, and 5% communication lines. In the nuclear power plant, medium voltage cables are generally included in the scope of systems reviewed for safety and are included in a plant's maintenance program. Medium voltage cables provide power to many critical components in plants, including feed water pumps, circulating water pumps, and condensate pumps. Among these cables, high temperature sections of cables feeding electrical power to the circulating water pump and the condenser extraction pump were found. The evaluation for these cables is performed to find the maximum allowable current and temperature. The result shows that the load current flowed about 85% of the allowable current ampacity, and the temperature of conductor at full load current did not exceed the limited temperature. Therefore, existing cables for circulating water pump and condenser extraction pump system are going to be used during design life.

  • PDF

콘크리트궤도 부설교량의 최대 신축장에 관한 연구 (Study on the Maximum Expansion Length of a Bridge with Contrete Track)

  • 최유복;최진유;박용걸;주환중;기인도
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.436-442
    • /
    • 2011
  • It is increasing construction of long span railway bridge with concrete track system for speed up of railway and efficient maintenance of track. As the sleeper of the concrete track system layed on a bridge is fixed on deck of the bridge, the displacement of the sleeper and deck is same. Therefore, the spacing between two sleeper installed at the end of the adjacent deck near the expansion joint of bridge becomes vary according to the longitudinal expansion of a deck by temperature change. By the way, if the spacing of sleepers become increase excessively, it causes large bending stress of in a rail, and it can leads failure or reduction of fatigue life of the rail. And also the excessive displacement of the rail may induce decrease ride comfort. Therefore, in order to prevent such problems, the allowable maximum sleeper spacing at a bridge expansion joint was mutually determined. And, the determination procedure of the maximum bridge expansion length based on the allowable sleeper spacing was suggested.

  • PDF

온도특성을 고려한 공항 저압간선의 경제적인 설계기법에 관한 연구 (A Study on the Economical Design of Airport Low-Voltage Feeder Which is considering the Temperature Character)

  • 최홍규;조계술;송영주
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.119-126
    • /
    • 2003
  • 공항과 같이 간선이 길게 포설될 수 있는 장소의 저압간선 굵기는 해당 케이블의 허용전류와 전력계통의 전압강하를 고려하며 결정된다. 비록 도체의 허용전류 값이 부하의 허용전류 값에 비하여 여유가 있을지라도 계통의 허용전압강하를 고려할 경우 도체의 굵기는 비교적 크게 산정될 수 있다. 이러한 경우에, 도체의 허용전류 값은 부하의 최대전류 값보다 훨씬 크게 산정될 수 있으며 상대적으로 도체에서 발생되는 열은 감소하게 된다. 도체의 최대 허용온도에 보정된 도체의 교류저항 값이 저압간선의 굵기 산정을 위한 전압강하 계산공식에 적용되어 왔으며, 도체의 저항 값은 도체의 실제 온도상승 값이 적용된 저항 값에 비하여 크다 본 연구는 도체의 실제 온도상승 값이 보정된 도체의 저항 값을 적용하여 저압간선 굵기 선정 설계 실무에 적용할 수 있도록 일반적인 계산 방식에 비하여 오차가 적은 경제적인 설계 방식을 연구하였다.

Heat spreader를 통한 PDP의 냉각성능 평가 (Evaluation of Cooling Performance of PDP by Heat Spreader)

  • 김재중;장석원;조영진;이태구;노홍구;이재헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.612-617
    • /
    • 2001
  • This paper reports the cooling performance of a PDP(plasma display panel) with a heat spreader by means of numerical analysis. Due to the simplifications and assumptions inherent in the analysis, computed results are found to differ those of the experiment by 13%. Calculation shows a maximum temperature of $65^{\circ}C$ for the plasma glass, as opposed to the allowable temperature of $90^{\circ}C$, producing a temperature difference of $25^{\circ}C$ between the upper and lower regions. This is enough to cause cracks in the plasma glass. In order to avoid this, more ventholes are added at the upper center region of the back cover, thereby causing a $3^{\circ}C$ drop in the maximum temperature, which reduces the temperature difference to $12^{\circ}C$. The new design gives more uniform temperature distribution across the plasma glass.

  • PDF

The Improved Design of Double Sided Coreless PMLSM with Consideration of Rising Winding Temperature

  • An, Ho-Jin;Cho, Gyu-Won;Jang, Ki-Bong;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.144-149
    • /
    • 2013
  • This work deals with the optimal design of a coreless PMLSM (Permanent Magnet Linear Synchronous Motor) with consideration of rising winding temperature. The temperature distribution caused by copper loss in the coreless PMLSM was analyzed using a FEM (Finite Element Method). The thrust and current density where the winding temperature reaches the allowable temperature were calculated. The optimal model provides maximum thrust per unit weight.